Fluid forces and their effects on cells have been researched for quite some time, especially in the realm of biology and medicine. Shear forces have been the primary emphasis, often attributed as being the main source of cell deformation/damage in devices like prosthetic heart valves and artificial organs. Less well understood and studied are extensional stresses which are often found in such devices, in bioreactors, and in normal blood circulation. Several microfluidic channels utilizing hyperbolic, abrupt, or tapered constrictions and cross-flow geometries, have been used to isolate the effects of extensional flow. Under such flow cell deformations, erythrocytes, leukocytes, and a variety of other cell types have been examined. Results suggest that extensional stresses cause larger deformation than shear stresses of the same magnitude. This has further implications in assessing cell injury from mechanical forces in artificial organs and bioreactors. The cells’ greater sensitivity to extensional stress has found utility in mechanophenotyping devices, which have been successfully used to identify pathologies that affect cell deformability. Further application outside of biology includes disrupting cells for increased food product stability and harvesting macromolecules for biofuel. The effects of extensional stresses on cells remains an area meriting further study.
Mechanical circulatory support (MCS) devices are designed to perform the functional needs of organs and to meet clinical hemocompability criteria. Critical complications have been reported with their long-term use such as thrombosis, anemia and gastrointestinal bleeding. Damage to red blood cells (RBCs), which occurs with nonphysiological blood flow conditions such as contact with foreign surfaces, high shear stress, and turbulence, is a major problem for the design and development of these systems. Even in the absence of hemolysis, cardiovascular devices (CAD) still cause cell injury and shortened RBC lifespans. This review summarizes various effects that occur to erythrocytes exposed to supraphysiological but sublethal stresses.
Utilization of a blood pump to aid in circulating a patient’s blood, otherwise known as mechanical circulatory support, is an effective and often life-saving treatment for cardiac/pulmonary failure patients, yet adverse events remain a common complication often attributed to mechanical trauma inflicted on blood components. This work specifically focuses on erythrocyte-derived extracellular vesicles (ErEVs) as a marker of this mechanical trauma as they are elevated in patients with blood pumps and have been tied to adverse events. Despite this, ErEVs are typically neglected during device development which usually includes testing with animal blood, most commonly porcine and bovine. Flow cytometry was employed to monitor ErEVs generated during a 6 h perfusion of porcine or bovine red blood cells (RBCs) in a blood circulatory loop with the CentriMag blood pump. Successful measurement meant overcoming limitations in suitable stains for the RBCs and ErEVs of the two species. Between the two species, 12 different antibodies and dyes were evaluated, including multiple glycophorin A clones, the typical human erythrocyte antigen. Only CD46 and carboxyfluorescein succinimidyl ester (CFSE) were found to successfully and reliably label porcine and bovine RBCs, respectively. With these stains, statistically significant increases for both porcine and bovine ErEVs with perfusion time were observed. Bovine erythrocytes produced significantly more ErEVs than porcine, indicating they are more sensitive to mechanical trauma and could be useful in early-stage device development. The utility of CD46 and CFSE used for porcine and bovine ErEV detection was demonstrated for in vitro pump testing with implications for physiological and pathological research with these animals.
8 June 2025 in Biochemistry and Biophysics Reports
Implantations of Ventricular Assist Devices (VADs) have significantly improved quality of life and life expectancy of end-stage heart failure patients. However, despite the advancements in the VAD designs and patient management protocols, the VAD recipients remain at risk of attaining bleeding, infection, pump thrombosis, and stroke. Although blood trauma has been suggested as a critical factor in development of these adverse events, its consequences in inducing interactions between different types of blood cells are largely unknown. Following our recent findings on erythrocyte and leukocyte trauma in VAD recipients, we decided to explore interactions between erythrocytes and leukocytes by perfusing human whole blood through two different types of VADs, HeartMate II (HMII) and HeartMate 3 (HM3), concurrently in their respective Blood Circulatory Loop (BCL). By using a flow cytometry assay, we found increasing association between erythrocytes and leukocytes as VADs propelled blood through their BCLs. This time-dependent intercellular association was shown by increasing concomitant events of stained CD235a (specifically expressed on erythrocytes) and stained CD45 (specifically expressed on leukocytes) in the CD235a+ population. Compared to CentriMag (CM), which served as a control, VADs produced significantly higher concomitant signals. The findings described in this study have opened the need for further studies on a novel path for generation of adverse events that are commonly observed in VAD recipients, notably infection, pump thrombosis, and ischemic stroke.
Mechanical circulatory support (MCS) advancement relies on fully understanding remaining hemocompatibility issues, including identifying and monitoring a variety of damage markers, as hemolysis alone is insufficient to understand the full scope of total blood damage. It is also important to understand how these alternative markers vary between species, as animal surrogates are often used in device development. This work focuses on evaluating erythrocyte-derived extracellular vesicles (ErEVs) released during MCS perfusion as an alternative marker for monitoring erythrocyte damage. Porcine, bovine, and human washed red blood cells (RBCs) were perfused through a blood circulatory loop using the CentriMag pump. Both hemolysis and ErEV production were monitored over time to compare the sensitivity of both to mechanically induced trauma and to observe species-dependent differences. All species produced significant increases in ErEV concentrations, while only human and bovine erythrocytes produced significant increases in free hemoglobin. There were no differences in the normalized index of hemolysis between species, but bovine RBCs produced significantly more ErEVs than human or porcine, which were similar. Regarding damage marker sensitivity, ErEV generation appears to be a promising complementary marker to hemolysis and potentially more sensitive for porcine and bovine models, while more testing is needed for human.