Long Chang

Dr. Long Chang

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2022 in Applied Energy
Verified
Journal Article
Closed access
Changlong LiChanglong Li
Changlong Li
NCNaxin Cui
Naxin Cui
Long ChangLong Chang
Long Chang
ZCZhongrui Cui
Zhongrui Cui
HYHaitao Yuan
Haitao Yuan
CZChenghui Zhang
Chenghui Zhang

28 February 2024 in Applied Thermal Engineering
Verified
Journal Article
Closed access
JZJinquan Zheng
Jinquan Zheng
Long ChangLong Chang
Long Chang
MMMingfei Mu
Mingfei Mu
JLJianbo Li
Jianbo Li
CLChanglong Li
Changlong Li
HDHenghui Du
Henghui Du

2 October 2023 in Batteries
Verified
Journal Article
Open access
PDF file
ZYZhihao Yu
Zhihao Yu
ZSZhezhe Sun
Zhezhe Sun
Long ChangLong Chang
Long Chang
CMChen Ma
Chen Ma
Changlong LiChanglong Li
Changlong Li
RHRuituo Huai
Ruituo Huai
Lithium-ion batteries are usually connected in series and parallel to form a pack for meeting the voltage and capacity requirements of energy storage systems. However, different pack configurations and battery module collector positions result in different equivalent connected resistances, leading to pack current inhomogeneity, which seriously reduces the lifetime and safety of the pack. Therefore, in order to quantitatively analyze the influence of the connected resistance on the current distribution, this study researched the initial cell current distribution of the parallel module by developing mathematical models of different configurations. Then, this study explored the influence of multiple module collector positions on the current inhomogeneity of the pack under the dynamic current condition. The results show that the inhomogeneity of cell current and discharge capacity in the pack with parallel modules connected in series can be improved by keeping each cell in a parallel module with the same distance to its module collector. Furthermore, the current homogeneity of the edge parallel modules in the pack is seriously affected by the position of the single module collector. Therefore, this study innovatively proposes the symmetrical multiple module collectors of the pack, which can greatly improve the current homogeneity of the edge parallel modules, thereby improving the lifetime and safety of the pack.

24 December 2021 in Separations
Verified
Journal Article
Open access
PDF file
YZYulong Zhang
Yulong Zhang
PLPeikun Liu
Peikun Liu
LXLinjing Xiao
Linjing Xiao
Long ChangLong Chang
Long Chang
FYFangping Yan
Fangping Yan
LJLanyue Jiang
Lanyue Jiang
In this study, a coal mine water flocculation system was established. A series of flocculation tests were carried out at different structural parameters (cylinder height, cone-plate insertion depth and cone-plate spacing) to better investigate the effect of the cone-plate clarifier on coal mine water treatment performance. Sixteen sampling points were set up in the system for data monitoring to generate the required data. The cone-plate clarifier was divided into five zones for flocculation analysis. The increased cylinder height facilitated the flocculation of particles in the micro flocculation zone and the settling of particles in the settlement zone. The chemicals used are polyaluminum chloride (PACl), Fe3O4 and polyacrylamide (PAM), corresponding to doses of 60 mg/L, 40 mg/L and 6 mg/L, respectively. Insufficient insertion depth of the cone-plate will cause the small flocs that have not been fully flocculated to enter the exit pipe zone directly through the cone-plate, while too much insertion depth will cause the large floc in the settlement zone to re-enter the exit pipe zone. The flocculation effect of small flocs increased as the cone-plate spacing decreased, which is consistent with the shallow pool theory. When the cone plate spacing was too narrow, the amount of fluid was reduced and the increase in fluid velocity reduced the flocculation effect. Curve fitting was conducted for Suspended solids(SS) and turbidity removal efficiency under each structural parameter to derive the variation of SS and turbidity removal efficiency under different structural parameters. The regression models of SS and turbidity removal efficiency on the cylinder height, cone-plate insertion depth and cone-plate spacing were established based on the curve fitting results, and the regression models were verified to be well fitted based on the comparison of experimental results. Finally, the optimal values of SS and turbidity removal efficiency were found based on the regression model. The flow rate of the cone-plate clarifier is 0.6 m3/h. The SS removal efficiency reached 96.82% when the cylinder height was 708 mm, the cone-plate insertion depth was 367 mm and the cone-plate spacing was 26 mm. The turbidity removal efficiency reached 86.75% when the cylinder height was 709 mm, the cone-plate insertion depth was 369 mm and the cone-plate spacing was 26 mm.

1 January 2025 in Journal of Mechanical Engineering
Verified
Journal Article
Closed access
PDF file
常龙常龙,杜恒珲,王炜斌,李长龙,于志豪,段彬
常龙,杜恒珲,王炜斌,李长龙,于志豪,段彬
Long ChangLong Chang
Long Chang