Circulating tumor cells (CTCs) have attracted increasing attention as important biomarkers for clinical and biological applications. Several microfluidic approaches have been demonstrated to separate CTCs using immunoaffinity or size difference from other blood cells. This study demonstrates a sheathless, high-throughput separation of CTCs from white blood cells (WBCs) using a viscoelastic fluid. To determine the fluid viscoelasticity and the flow rate for CTC separation, and to validate the device performance, flow characteristics of 6, 13, and 27 μm particles in viscoelastic fluids with various concentrations were estimated at different flow rates. Using 0.2% hyaluronic acid (HA) solution, MCF-7 (Michigan Cancer Foundation-7) cells mimicking CTCs in this study were successfully separated from WBCs at 500 μL/min with a separation efficiency of 94.8%. Small amounts of MCF-7 cells (~5.2%) were found at the center outlet due to the size overlap with WBCs.
Intervertebral disc (IVD) degeneration is associated with imbalances between catabolic and anabolic responses, regulated by extracellular matrix (ECM)-modifying enzymes such as matrix metalloproteinases (MMPs) and their endogenous tissue inhibitors of metalloproteinases (TIMPs). Potential contributing factors, such as interleukin (IL)-1β and tumor necrosis factor (TNF)-α, derived from infiltrated, activated macrophages within IVD tissues, can trigger abnormal production of ECM-modifying enzymes and progression of IVD degeneration. Novel therapies for regulating ECM-modifying enzymes can prevent or ameliorate IVD degeneration. Photobiomodulation (PBM), known to regulate wound repair, exhibits regenerative potential by modulating biological molecules. This study examined the effects of PBM, administered at various wavelengths (630, 525, and 465 nm) and energy densities (16, 32, and 64 J/cm2), on the production of ECM-modifying enzymes in replicated degenerative IVD. Our results showed that PBM selectively inhibited the production of ECM-modifying enzymes in a dose- and wavelength-dependent manner, suggesting that it could be a novel tool for treating symptomatic IVD degeneration.
Degenerative cascades of the intervertebral disc (IVD) are characterized by the presence of immune cells like monocytes, macrophages, and leukocytes, which contribute to inflammation. Previous in vitro studies on monocyte chemotaxis in the presence of chemical or mechanical stimulation were unable to establish the effects of endogenous stimulating factors from resident IVD cells, or fully understand macrophage and monocyte differentiation pathways in IVD degeneration. Our study simulates monocyte extravasation using a fabricated microfluidic chemotaxis IVD organ-on-a-chip (IVD organ chip), which models the geometry of IVD, chemoattractant diffusion, and infiltration of immune cells. Additionally, the fabricated IVD organ chip mimics stepwise monocyte infiltration and differentiation into macrophages in the degenerative nucleus pulposus (NP) induced by IL-1β. We find that naïve NP cells do not recruit THP-1 monocyte-like cells, but degenerative NP cells recruit and accumulate macrophages through chemo-gradient channels. Furthermore, the differentiated and migrated THP-1 cells show phagocytic activity around inflammatory NP cells. Our in vitro model of monocyte chemotaxis with degenerative NP on an IVD organ chip depicts the sequential processes of monocyte migration/infiltration, monocyte-to-macrophage differentiation, and accumulation. Using this platform to gain a deeper understanding of monocyte infiltration and differentiation processes can provide insights into the pathophysiology of the immune response in degenerative IVD.
Electrical stimulation of cells and tissues for therapeutic benefit is a well-established method. Although animal studies can emulate the complexity of an organism’s physiology, lab-on-a-chip platforms provide a suitable primary model for follow-up animal studies. Thus, inexpensive and easy-to-use platforms for in vitro human cell studies are required. In the present study, we designed a micro-electrical impulse (micro-EI)-on-a-chip (micro-EI-chip), which can precisely control electron density and adjust the frequency based on a micro-EI. The micro-EI-chip can stimulate cells at various micro-EI densities (0–500 mV/mm) and frequencies (0–300 Hz), which enables multiple co-culture of different cell types with or without electrical stimulation. As a proof-of-concept study, a model involving degenerative inflamed human annulus fibrosus (hAF) cells was established in vitro and the effects of micro-EI on inflamed hAF cells were evaluated using the micro-EI-chip. Stimulation of the cells (150 mV/mm at 200 Hz) inhibited the secretion of inflammatory cytokines and downregulated the activities of extracellular matrix-modifying enzymes and matrix metalloproteinase-1. These results show that micro-EI stimulation could affect degenerative diseases based on inflammation, implicating the micro-EI-chip as being useful for basic research of electroceuticals.
Intervertebral disc (IVD) degeneration is a major cause of low back pain (LBP) in the lumbar spine. This phenomenon is caused by several processes, including matrix degradation in IVD tissues, which is mediated by matrix metalloproteinases (MMPs) and inflammatory responses, which can be mediated by interactions among immune cells, such as macrophages and IVD cells. In particular, interleukin (IL)-1 beta (β), which is a master regulator secreted by macrophages, mediates the inflammatory response in nucleus pulposus cells (NP) and plays a significant role in the development or progression of diseases. In this study, we developed a custom electrical stimulation (ES) platform that can apply low-constant-current stimulation (LCCS) signals to microfluidic chips. Using this platform, we examined the effects of LCCS on IL-1β-mediated inflammatory NP cells, administered at various currents (5, 10, 20, 50, and 100 μA at 200 Hz). Our results showed that the inflammatory response, induced by IL-1β in human NP cells, was successfully established. Furthermore, 5, 10, 20, and 100 μA LCCS positively modulated inflamed human NP cells’ morphological phenotype and kinetic properties. LCCS could affect the treatment of degenerative diseases, revealing the applicability of the LCCS platform for basic research of electroceuticals.
The degeneration of an intervertebral disc (IVD) is a major cause of lower back pain. IVD degeneration is characterized by the abnormal expression of inflammatory cytokines and matrix degradation enzymes secreted by IVD cells. In addition, macrophage-mediated inflammation is strongly associated with IVD degeneration. However, the precise pathomechanisms of macrophage-mediated inflammation in IVD are still unknown. In this study, we developed a microfluidic platform integrated with an electrical stimulation (ES) array to investigate macrophage-mediated inflammation in human nucleus pulposus (NP). This platform provides multiple cocultures of different cell types with ES. We observed macrophage-mediated inflammation and considerable migration properties via upregulated expression of interleukin (IL)-6 (p < 0.001), IL-8 (p < 0.05), matrix metalloproteinase (MMP)-1 (p < 0.05), and MMP-3 (p < 0.05) in human NP cells cocultured with macrophages. We also confirmed the inhibitory effects of ES at 10 μA due to the production of IL-6 (p < 0.05) and IL-8 (p < 0.01) under these conditions. Our findings indicate that ES positively affects degenerative inflammation in diverse diseases. Accordingly, the microfluidic electroceutical platform can serve as a degenerative IVD inflammation in vitro model and provide a therapeutic strategy for electroceuticals.