David Edmond Gleeson

Dr. David Edmond Gleeson


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in Journal of Dairy Science
Verified
Journal Article
Closed access
AOA. O’cOnnell
A. O’cOnnell
PRP.L. Ruegg
P.L. Ruegg
KJK. Jordan
K. Jordan
BOB. O’bRien
B. O’bRien
DGDavid Edmond Gleeson
David Edmond Gleeson
The dairy industry in Ireland is currently undergoing a period of expansion and, as a result, it is anticipated that milk may be stored in bulk tanks on-farm for periods greater than 48 h. The objective of this study was to investigate the effects of storage temperature and duration on microbial quality of bulk tank milk when fresh milk is added to the bulk tank twice daily. Bulk tank milk stored at 3 temperatures was sampled at 24-h intervals during storage periods of 0 to 96 h. Bulk tank milk samples were analyzed for total bacterial count (TBC), psychrotrophic bacterial count (PBC), laboratory pasteurization count (LPC), psychrotrophic-thermoduric bacterial count (PBC-LPC), proteolytic bacterial count, lipolytic bacterial count, presumptive Bacillus cereus, sulfite-reducing Clostridia (SRC), and SCC. The bulk tank milk temperature was set at each of 3 temperatures (2°C, 4°C, and 6°C) in each of 3 tanks on 2 occasions during two 6-wk periods. Period 1 was undertaken in August and September, when all cows were in mid lactation, and period 2 was undertaken in October and November, when all cows were in late lactation. None of the bulk tank bacterial counts except the proteolytic count were affected by lactation period. The proteolytic bacterial count was greater in period 2 than in period 1. The TBC and PBC of milk stored at 6°C increased as storage duration increased. The TBC did not increase with increasing storage duration when milk was stored at 2°C or 4°C but the PBC of milk stored at 4°C increased significantly between 0 and 96 h. The numbers of proteolytic and lipolytic bacteria, LPC, or PBC-LPC in bulk tank milk were not affected by temperature or duration of storage. Presumptive B. cereus were detected in 10% of all bulk tank milk samples taken over the two 6-wk periods, with similar proportions observed in both. In bulk tank milk samples, a greater incidence of SRC was observed in period 2 (20%) compared with period 1 (3%). Milk produced on-farm with minimal bacterial contamination can be successfully stored at 2°C and 4°C for up to 96h with little effect on its microbial quality.

1 July 2009 in Irish Veterinary Journal
Verified
Journal Article
Open access
PDF file
DGDavid Edmond Gleeson
David Edmond Gleeson
BOB O'BRien
B O'BRien
JFJ Flynn
J Flynn
EOE O'CAllaghan
E O'CAllaghan
FGF Galli
F Galli
A study was carried out to investigate the effect of six pre-milking teat preparation procedures on lowering the staphylococal, streptococcal and coliform microbial count on teat skin prior to cluster application. The teat preparations included 'Iodine', 'Chlorhexidine' teat foam, 'Washing and drying' with paper, 'No preparation', 'Chlorine' teat foam, and disinfectant 'Wipes'. Teat preparations were applied for five days to 10 cows for each treatment during two herd management periods (indoors and outdoors). Teats were swabbed on day four and five before teat preparation and repeated after teat preparation. The swabs were plated on three selective agars: Baird Parker (Staphylococcus spp.), Edwards (Streptococcus spp.), and MacConkey (coliform). Following incubation, microbial counts for each pathogen type were manually counted and assigned to one of six categories depending on the microbial counts measured. The results were analysed by logistic regression using SAS 28. The main analysis was conducted on binary improvement scores for the swabbing outcomes. There were no differences for staphylococcal, streptococcal and coliform bacterial counts between treatments, measured 'before' teat preparation. Treatments containing 'Chlorhexidine' teat foam (OR = 4.46) and 'Wipes' (OR = 4.46) resulted in a significant reduction (P < 0.01) in the staphylococcal count on teats compared to 'Washing and drying' or 'No preparation'. 'Chlorine' teat foam (OR = 3.45) and 'Wipes' (3.45) had the highest probability (P < 0.01) of reducing streptococcal counts compared to 'Washing and drying' or 'No preparation'. There was no statistical difference between any of the disinfectant treatments applied in reducing coliforms. Thus, the use of some disinfectant products for pre-milking teat preparation can have beneficial effects on reducing the levels of staphylococcal and streptococcal pathogens on teat skin.

18 April 2018 in Irish Veterinary Journal
Verified
Journal Article
Open access
PDF file
DGDavid Edmond Gleeson
David Edmond Gleeson
JFJimmy Flynn
Jimmy Flynn
BBBernadette O’ Brien
Bernadette O’ Brien
The practise of teat disinfection prior to cluster attachment for milking is being adopted by farmers in Ireland, particularly where there are herd issues with new infection rates. Pre-milking teat disinfection has been shown to reduce bacterial numbers on teat skin and to be most effective against environmental bacteria such as Escherichia coli and Streptococcus uberis. A split udder design experiment was undertaken on two research herds (A = 96 cows: B = 168 cows) to test the benefit of pre-milking teat disinfection on new mastitis infection levels. The disinfectant was applied to the left front and right hind teats of all cows in each herd and the right front and left hind teats received no disinfectant treatment prior to milking over a complete lactation. Individual quarter foremilk samples were taken on 5 occasions during the lactation and all clinical cases were recorded. The presence and number of staphylococcus and streptococcus bacteria on teat skin of a random sample of experimental cows (n = 20) was measured on 3 occasions during lactation (April, June, and October). Pre-milking teat disinfection had no significant impact on quarter SCC and new infection rates (P > 0.05). The median SCC was 169 (95% CI = 144–198) × 103 cells/mL and 170 (95% CI = 145–199) × 103 cells/mL for disinfected teats and non-disinfected teats, respectively. There were no differences in SCC observed between herds (A = 161 (95% CI = 127–205) × 103 cells/mL; B = 169 (95% CI = 144–198) × 103 cells/mL) over the complete lactation. Bacterial levels on teat skin were reduced significantly with pre-milking teat disinfection compared to teats receiving no disinfectant (P < 0.001). Total infections (clinical and sub-clinical) were similar for disinfected teats (n = 36) and not disinfected teats (n = 40), respectively. Staphylococcus aureus (n = 47) and Strep. uberis (n = 9) were identified as the predominant bacteria in quarter foremilk samples with both clinical and sub-clinical infections. SCC and new infection rates were similar in non-disinfected teats and disinfected (pre-milking) teats. The routine application of pre-milking teat disinfectant in pasture-grazed herds is unlikely to be of benefit where herd SCC is below 200 × 103 cells/mL.

2 January 2021 in Irish Veterinary Journal
Verified
Journal Article
Open access
PDF file
SFSarah Rose Fitzpatrick
Sarah Rose Fitzpatrick
MGMary Garvey
Mary Garvey
JFJim Flynn
Jim Flynn
BOBernadette O’bRien
Bernadette O’bRien
DGDavid Edmond Gleeson
David Edmond Gleeson
Background: Teat disinfection is an important step in the control of mastitis within a dairy herd. The objective of this study was to evaluate the effectiveness of 96 commercially available teat disinfectant products in Ireland against bacterial isolates on teat skin. Teat disinfection products were applied to the teats of seventeen Holstein–Friesian cows. A split-udder model was used where one cow received two different teat disinfection products on each day. A composite swab sample was taken of the left teats and the right teats before and after teat disinfectant application. Swab samples were plated onto 3 different selective agars to enumerate bacterial counts of streptococcal, staphylococcal and coliform isolates. Results: Streptococcal isolates were the most prominent bacterial group recovered on teat swabs taken before the application of a teat disinfection product (55.0%), followed by staphylococcal isolates (41.3%) and coliform isolates (3.7%). Products were reclassified by active ingredients (n = 9) for analysis. These ingredient groups included; chlorhexidine, chlorine dioxide, diamine, iodine, iodine and lactic acid, lactic acid, lactic acid and chlorhexidine, lactic acid and hydrogen peroxide, and lactic acid and salicylic acid. The ingredient group, chlorine dioxide, resulted in comparable reductions to the iodine group for streptococcal isolates. The ingredient group, iodine combined with lactic acid, resulted in the greatest reduction of staphylococcal isolates. When observing products individually, a product containing 1.6% w/w lactic acid combined with hydrogen peroxide was the most effective at reducing streptococcal isolates on the teat skin, whereas a product containing lactic acid combined with 0.6% w/w chlorhexidine was the most effective against staphylococcal isolates. Minor differences were observed regarding the relationship between effectiveness and active ingredient concentration between products. Conclusions: This study suggests that some teat disinfectant products achieve a higher reduction in bacterial levels against different specific bacterial groups on teat skin than other products. Therefore, when choosing a teat disinfectant product, the bacteria in the dairy herds’ environment should be considered. Further studies are necessary to evaluate products efficacy against new IMIs and any possible effects on teat skin condition.

1 March 2018 in Journal of Dairy Science
Verified
Journal Article
Open access
LPLizandra F. Paludetti
Lizandra F. Paludetti
AKAlan Kelly
Alan Kelly
BOBernadette O'BRien
Bernadette O'BRien
KJKieran Jordan
Kieran Jordan
DGDavid Edmond Gleeson
David Edmond Gleeson
The objective of this study was to measure the effect of different milk cooling rates, before entering the bulk tank, on the microbiological load and composition of the milk, as well as on energy usage. Three milk precooling treatments were applied before milk entered 3 identical bulk milk tanks: no plate cooler (NP), single-stage plate cooler (SP), and double-stage plate cooler (DP). These precooling treatments cooled the milk to 32.0 ± 1.4°C, 17.0 ± 2.8°C, and 6.0 ± 1.1°C, respectively. Milk was added to the bulk tank twice daily for 72 h, and the tank refrigeration temperature was set at 3°C. The blend temperature within each bulk tank was reduced after each milking event as the volume of milk at 3°C increased simultaneously. The bacterial counts of the milk volumes precooled at different rates did not differ significantly at 0 h of storage or at 24-h intervals thereafter. After 72 h of storage, the total bacterial count of the NP milk was 3.90 ± 0.09 log10 cfu/mL, whereas that of the precooled milk volumes were 3.77 ± 0.09 (SP) and 3.71 ± 0.09 (DP) log10 cfu/mL. The constant storage temperature (3°C) over 72 h helped to reduce bacterial growth rates in milk; consequently, milk composition was not affected and minimal, if any, proteolysis occurred. The DP treatment had the highest energy consumption (17.6 ± 0.5 Wh/L), followed by the NP (16.8 ± 2.7 Wh/L) and SP (10.6 ± 1.3 Wh/L) treatments. This study suggests that bacterial count and composition of milk are minimally affected when milk is stored at 3°C for 72 h, regardless of whether the milk is precooled; however, milk entering the tank should have good initial microbiological quality. Considering the numerical differences between bacterial counts, however, the use of the SP or DP precooling systems is recommended to maintain low levels of bacterial counts and reduce energy consumption.

1 February 2017 in Journal of Dairy Science
Verified
Journal Article
Open access
PDF file
AOA. O'COnnell
A. O'COnnell
AKAlan Kelly
Alan Kelly
JTJ. Tobin
J. Tobin
PRP.L. Ruegg
P.L. Ruegg
DGDavid Edmond Gleeson
David Edmond Gleeson
The objective of this study was to investigate the effects of storage temperature and duration on the composition and functional properties of bulk tank milk when fresh milk was added to the bulk tank twice daily. The bulk tank milk temperature was set at each of 3 temperatures (2, 4, and 6°C) in each of 3 tanks on 2 occasions during two 6-wk periods. Period 1 was undertaken in August and September when all cows were in mid lactation, and period 2 was undertaken in October and November when all cows were in late lactation. Bulk tank milk stored at the 3 temperatures was sampled at 24-h intervals during storage periods of 0 to 96 h. Compositional parameters were measured for all bulk tank milk samples, including gross composition and quantification of nitrogen compounds, casein fractions, free amino acids, and Ca and P contents. The somatic cell count, heat stability, titratable acidity, and rennetability of bulk tank milk samples were also assessed. Almost all parameters differed between mid and late lactation; however, the interaction between lactation, storage temperature, and storage duration was significant for only 3 parameters: protein content and concentrations of free cysteic acid and free glutamic acid. The interaction between storage temperature and storage time was not significant for any parameter measured, and temperature had no effect on any parameter except lysine: lysine content was higher at 6°C than at 2°C. During 96 h of storage, the concentrations of some free amino acids (glutamic acid, lysine, and arginine) increased, which may indicate proteolytic activity during storage. Between 0 and 96 h, minimal deterioration was observed in functional properties (rennet coagulation time, curd firmness, and heat stability), which was most likely due to the dissociation of β-casein from the casein micelle, which can be reversed upon pasteurization. Thus, this study suggests that blended milk can be stored for up to 96 h at temperatures between 2°C and 6°C with little effect on its composition or functional properties.