Luigi Gabrielli

Luigi Gabrielli


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2021 in Frontiers in Molecular Biosciences
Verified
Journal Article
Open access
PDF file
PVPaulina Villar-Fincheira
Paulina Villar-Fincheira
FSFernanda Sanhueza-Olivares
Fernanda Sanhueza-Olivares
INIgnacio Norambuena-Soto
Ignacio Norambuena-Soto
NCNicole Cancino-Arenas
Nicole Cancino-Arenas
FHFelipe Hernandez-Vargas
Felipe Hernandez-Vargas
MCMario Chiong
Mario Chiong
IL-6 is usually described as a pleiotropic cytokine produced in response to tissue injury or infection. As a pro-inflammatory cytokine, IL-6 activates innate and adaptative immune responses. IL-6 is released in the innate immune response by leukocytes as well as stromal cells upon pattern recognition receptor activation. IL-6 then recruits immune cells and triggers B and T cell response. Dysregulated IL-6 activity is associated with pathologies involving chronic inflammation and autoimmunity, including atherosclerosis. However, IL-6 is also produced and released under beneficial conditions, such as exercise, where IL-6 is associated with the anti-inflammatory and metabolic effects coupled with physical adaptation to intense training. Exercise-associated IL-6 acts on adipose tissue to induce lipogenesis and on arteries to induce adaptative vascular remodeling. These divergent actions could be explained by complex signaling networks. Classical IL-6 signaling involves a membrane-bound IL-6 receptor and glycoprotein 130 (gp130), while trans-signaling relies on a soluble version of IL-6R (sIL-6R) and membrane-bound gp130. Trans-signaling, but not the classical pathway, is regulated by soluble gp130. In this review, we discuss the similarities and differences in IL-6 cytokine and myokine signaling to explain the differential and opposite effects of this protein during inflammation and exercise, with a special focus on the vascular system.

29 May 2012 in Echocardiography
Verified
Journal Article
Closed access
PDF file
LGLuigi Gabrielli
Luigi Gabrielli
AEAndrés Enríquez
Andrés Enríquez
SCSamuel Córdova
Samuel Córdova
FYFernando Yáñez
Fernando Yáñez
IGIván Godoy
Iván Godoy
RCRamon Corbalán
Ramon Corbalán

22 February 2014 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
LGLuigi Gabrielli
Luigi Gabrielli
BBBart H. Bijnens
Bart H. Bijnens
CBConstantine Butakoff
Constantine Butakoff
NDNicolas Duchateau
Nicolas Duchateau
SMSilvia Montserrat
Silvia Montserrat
MSMarta Sitges
Marta Sitges

4 October 2011 in Echocardiography
Verified
Journal Article
Closed access
PDF file
LGLuigi Gabrielli
Luigi Gabrielli
RCRamon Corbalan
Ramon Corbalan
SCSamuel Córdova
Samuel Córdova
AEAndrés Enríquez
Andrés Enríquez
PNPaul Mc Nab
Paul Mc Nab
SLSergio Lavandero
Sergio Lavandero

16 August 2019 in Journal of Sports Sciences
Verified
Journal Article
Closed access
Felipe Contreras–BriceñoFelipe Contreras–Briceño
Felipe Contreras–Briceño
MEMaximiliano Espinosa
Maximiliano Espinosa
GHGonzalo Hevia
Gonzalo Hevia
DLDiego Llambias
Diego Llambias
MCMiguel Carrasco
Miguel Carrasco
Ginés ViscorGinés Viscor
Ginés Viscor
This study assessed the intra-individual reliability of oxygen saturation in intercostal muscles (SmO2-m.intercostales) during an incremental maximal treadmill exercise by using portable NIRS devices in a test-retest study. Fifteen marathon runners (age, 24.9 ± 2.0 years; body mass index, 21.6 ± 2.3 kg·m−2; V̇O2-peak, 63.7 ± 5.9 mL·kg−1·min−1) were tested on two separate days, with a 7-day interval between the two measurements. Oxygen consumption (V̇O2) was assessed using the breath-by-breath method during the V̇O2-test, while SmO2 was determined using a portable commercial device, based in the near-infrared spectroscopy (NIRS) principle. The minute ventilation (VE), respiratory rate (RR), and tidal volume (Vt) were also monitored during the cardiopulmonary exercise test. For the SmO2-m.intercostales, the intraclass correlation coefficient (ICC) at rest, first (VT1) and second ventilatory (VT2) thresholds, and maximal stages were 0.90, 0.84, 0.92, and 0.93, respectively; the confidence intervals ranged from −10.8% – +9.5% to −15.3% – +12.5%. The reliability was good at low intensity (rest and VT1) and excellent at high intensity (VT2 and max). The Spearman correlation test revealed (p ≤ 0.001) an inverse association of SmO2-m.intercostales with V̇O2 (ρ = −0.64), VE (ρ = −0.73), RR (ρ = −0.70), and Vt (ρ = −0.63). The relationship with the ventilatory variables showed that increased breathing effort during exercise could be registered adequately using a NIRS portable device.

10 January 2016 in Scandinavian Journal of Medicine & Science in Sports
Verified
Journal Article
Closed access
PDF file
LGLuigi Gabrielli
Luigi Gabrielli
BBB. H. Bijnens
B. H. Bijnens
CBC. Brambila
C. Brambila
NDNicolas Duchateau
Nicolas Duchateau
JMJ. Marin
J. Marin
MSM. Sitges
M. Sitges