Hongchul Sohn

Dr. Hongchul Sohn

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
CSCole S. Simpson
Cole S. Simpson
HSHongchul Sohn
Hongchul Sohn
JAJessica L. Allen
Jessica L. Allen
LTLena H. Ting
Lena H. Ting

1 April 2013 in Journal of Biomechanics
Verified
Journal Article
Closed access
HSHongchul Sohn
Hongchul Sohn
JMJ. Lucas McKay
J. Lucas McKay
LTLena H. Ting
Lena H. Ting

4 February 2016 in Frontiers in Computational Neuroscience
Verified
Journal Article
Open access
HSHongchul Sohn
Hongchul Sohn
LTLena H. Ting
Lena H. Ting
We used a musculoskeletal model to investigate the possible biomechanical and neural bases of using consistent muscle synergy patterns to produce functional motor outputs across different biomechanical conditions, which we define as generalizability. Experimental studies in cats demonstrate that the same muscle synergies are used during reactive postural responses at widely varying configurations, producing similarly-oriented endpoint force vectors with respect to the limb axis. However, whether generalizability across postures arises due to similar biomechanical properties or to neural selection of a particular muscle activation pattern has not been explicitly tested. Here, we used a detailed cat hindlimb model to explore the set of feasible muscle activation patterns that produce experimental synergy force vectors at a target posture, and tested their generalizability by applying them to different test postures. We used three methods to select candidate muscle activation patterns: (1) randomly-selected feasible muscle activation patterns, (2) optimal muscle activation patterns minimizing muscle effort at a given posture, and (3) generalizable muscle activation patterns that explicitly minimized deviations from experimentally-identified synergy force vectors across all postures. Generalizability was measured by the deviation between the simulated force direction of the candidate muscle activation pattern and the experimental synergy force vectors at the test postures. Force angle deviations were the greatest for the randomly selected feasible muscle activation patterns (e.g. >100°), intermediate for effort-wise optimal muscle activation patterns (e.g. ~20°), and smallest for generalizable muscle activation patterns (e.g. <5°). Generalizable muscle activation patterns were suboptimal in terms of effort, often exceeding 50% of the maximum possible effort (cf. ~5% in minimum-effort muscle activation patterns). The feasible muscle activation ranges of individual muscles associated with producing a specific synergy force vector was reduced by ~45% when generalizability requirements were imposed. Muscles recruited in the generalizable muscle activation patterns had less sensitive torque-producing characteristics to changes in postures. We conclude that generalization of function across postures does not arise from limb biomechanics or a single optimality criterion. Muscle synergies may reflect acquired motor solutions globally tuned for generalizability across biomechanical contexts, facilitating rapid motor adaptation.

17 May 2012 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
NBNathan E. Bunderson
Nathan E. Bunderson
JBJeffrey T. Bingham
Jeffrey T. Bingham
HSHongchul Sohn
Hongchul Sohn
LTLena H. Ting
Lena H. Ting
TBThomas J. Burkholder
Thomas J. Burkholder

24 July 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HSHongchul Sohn
Hongchul Sohn
DSDaniel M Smith
Daniel M Smith
LTLena H Ting
Lena H Ting
The robustness of motor outputs to muscle dysfunction has been investigated using musculoskeletal modeling, but with conflicting results owing to differences in model complexity and motor tasks. Our objective was to systematically study how the number of kinematic degrees of freedom, and the number of independent muscle actuators alter the robustness of motor output to muscle dysfunction. We took a detailed musculoskeletal model of the human leg and systematically varied the model complexity to create six models with either 3 or 7 kinematic degrees of freedom and either 14, 26, or 43 muscle actuators. We tested the redundancy of each model by quantifying the reduction in sagittal plane feasible force set area when a single muscle was removed. The robustness of feasible force set area to the loss of any single muscle, i.e. general single muscle loss increased with the number of independent muscles and decreased with the number of kinematic degrees of freedom, with the robust area varying from 1% and 52% of the intact feasible force set area. The maximum sensitivity of the feasible force set to the loss of any single muscle varied from 75% to 26% of the intact feasible force set area as the number of muscles increased. Additionally, the ranges of feasible muscle activation for maximum force production were largely unconstrained in many cases, indicating ample musculoskeletal redundancy even for maximal forces. We propose that ratio of muscles to kinematic degrees of freedom can be used as a rule of thumb for estimating musculoskeletal redundancy in both simulated and real biomechanical systems.

1 February 2022 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Open access
EBEmma M. Baillargeon
Emma M. Baillargeon
DLDaniel Ludvig
Daniel Ludvig
HSHongchul Sohn
Hongchul Sohn
CNConstantine P. Nicolozakes
Constantine P. Nicolozakes
ASAmee L. Seitz
Amee L. Seitz
EPEric J. Perreault
Eric J. Perreault
Daily tasks rely on our ability to generate multi-dimensional shoulder torques. When function is limited, strength assessments are used to identify impairments and guide treatment. However, these assessments are often one-dimensional and limited in their sensitivity to diagnose shoulder pathology. To address these limitations, we have proposed novel metrics to quantify shoulder torque capacity in all directions. To quantify the feasible torque space of the shoulder, we measured maximal volitional shoulder torques in 32 unique directions and fit an ellipsoid model to these data. This ellipsoid model was used to quantify overall strength magnitude, strength balance, and the directions in which participants were strongest and weakest. We used these metrics to characterize three-dimensional shoulder strength in healthy adults and demonstrated their repeatability across days. Finally, using musculoskeletal simulations, we showed that our proposed metrics can distinguish between changes in muscle strength associated with aging or rotator cuff tears and quantified the influence of altered experimental conditions on this diagnostic capacity. Our results demonstrate that the proposed metrics can robustly quantify the feasible torque space of the shoulder and may provide a clinically useful description of the functional capacity of the shoulder in health and disease.