A fluorescent photochromic compound, composed of diarylethene, fluorescein and succinimidyl ester units, was developed for the controllable fluorescent labeling of biomolecules based on a small molecule.
24 February 2016 in Chemistry – A European Journal
A swallow-tailed perylene derivative including a triphenylphosphine moiety was synthesized and applied to the detection and the live-cell imaging of lipid hydroperoxides. The novel probe, named Spy-LHP, reacted rapidly and quantitatively with lipid hydroperoxides to form the corresponding oxide, Spy-LHPOx, which emits extremely strong fluorescence (Φ ∼ 1) in the visible range (λem = 535 nm, 574 nm). Spy-LHP was highly selective for lipid hydroperoxides, and the addition of other reactive oxygen species (ROS) including hydrogen peroxides, hydroxyl radical, superoxide anion, nitric oxide, peroxynitrite, and alkylperoxyl radical, caused no significant increase in the fluorescence intensity. The probe exhibited good localization to cellular membranes and was successfully applied to the confocal laser scanning microscopy (CLSM) imaging of lipid hydroperoxides in live J774A.1 cells, in which lipid peroxidation was proceeded by the stimulation of 2,2-azobis(2-amidinopropane)dihydrochloride (AAPH). These findings establish Spy-LHP as a promising new tool for investigating the physiology of lipid hydroperoxides.
A novel fluorescent probe, the detection mechanism of which is based on the ‘on-off’ switching of a FRET triggered by the ˙OH-induced cleavage of a DNA strand, has been developed for the ratiometric imaging of ˙OH.
A gas diffusion sequential injection system with amperometric detection using aboron-doped diamond electrode was developed for the determination of sulfite. A gasdiffusion unit (GDU) was used to prevent interference from sample matrices for theelectrochemical measurement. The sample was mixed with an acid solution to generategaseous sulfur dioxide prior to its passage through the donor channel of the GDU. Thesulfur dioxide diffused through the PTFE hydrophobic membrane into a carrier solution of 0.1 M phosphate buffer (pH 8)/0.1% sodium dodecyl sulfate in the acceptor channel of theGDU and turned to sulfite. Then the sulfite was carried to the electrochemical flow cell anddetected directly by amperometry using the boron-doped diamond electrode at 0.95 V(versus Ag/AgCl). Sodium dodecyl sulfate was added to the carrier solution to preventelectrode fouling. This method was applicable in the concentration range of 0.2-20 mgSO32−/L and a detection limit (S/N = 3) of 0.05 mg SO32−/L was achieved. This method wassuccessfully applied to the determination of sulfite in wines and the analytical resultsagreed well with those obtained by iodimetric titration. The relative standard deviations forthe analysis of sulfite in wines were in the range of 1.0-4.1 %. The sampling frequency was65 h−1.