Lars-Rene Tuecking

Dr. Lars-Rene Tuecking

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2024 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Open access
PDF file
MEMax Ettinger
Max Ettinger
LTLars-Rene Tuecking
Lars-Rene Tuecking
PSPeter Savov
Peter Savov
HWHenning Windhagen
Henning Windhagen
Purpose: Restricted kinematic alignment (rKA) in total knee arthroplasty (TKA) and medial pivot (MP) knee designs already showed superior outcomes in independent comparative studies. The objective of this study was to assess whether rKA with MP TKA provides better clinical and functional outcomes compared to mechanical alignment (MA) with MP TKA.Methods: This is a randomised, parallel two group study involving a total of 98 patients with end‐stage knee osteoarthritis. Patients were randomly allocated to either rKA or MA TKA procedures conducted with a MP prothesis using patient‐specific instruments between 2017 and 2020. Final follow‐up was at 2 years postoperatively. Demographic data and clinical and functional scores (Oxford knee score, knee society score [KSS], Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC], forgotten joint score [FJS]) were collected and compared preoperative, 1 year postoperative and 2 years postoperative. Coronal plane alignment of the knee and functional knee phenotype classification were recorded.Results: A total of 47 patients (rKA) and 51 patients (MA) were included in final analysis. Superior joint awareness scores (FJS) were found at 1 year postoperative for rKA (62.2 vs. 52.4, p = 0.04). KSS subscores (expectation score, satisfaction score) improved with rKA with significant differences at both 1 and 2 years postoperatively. Major differences between rKA and MA were found in subgroup analysis of varus and neutral CPAK phenotypes. Both 1 year and 2 years postoperatively, FJS was significantly better in KA compared with MA in varus CPAK phenotypes (63.1 vs. 44.9, p = 0.03; 71.1 vs. 46.0, p = 0.005). Further clinical and functional scores showed improvement in the varus CPAK phenotypes with predominantly significant improvement in the expectation and satisfaction KSS subscores. No significant differences were found in the comparison of rKA and MA in neutral CPAK phenotypes.Conclusion: The rKA of MP TKA design shows superior patient satisfaction and self‐reported function when compared to MA MP TKA. Furthermore, rKA MP TKA shows superior joint awareness at early postoperative stage. The most important clinical relevance of this study is the clear superiority of rKA in varus phenotypes.Level of Evidence: Level II.

29 October 2021 in Der Orthopäde
Verified
Journal Article
Open access
PDF file
LTLars-Rene Tuecking
Lars-Rene Tuecking
PSPeter Savov
Peter Savov
HWHenning Windhagen
Henning Windhagen
SJSimon Jennings
Simon Jennings
DNDinesh Nathwani
Dinesh Nathwani
MEMax Ettinger
Max Ettinger
Background and objective: It is evident from the national joint registries that numbers of revision knee arthroplasty operations are rising. The aim of this article is to introduce a new robotic-assisted approach in UKA to TKA revision arthroplasty and investigate the alignment accuracy, implant component use and surgery time and to compare it to primary robotic-assisted TKA arthroplasty. Methods: This retrospective, case-control study included patients undergoing image-less robotic-assisted revision arthroplasty from UKA to TKA (n = 20) and patients undergoing image-less robotic-assisted primary TKA (control group, n = 20) from 11/2018 to 07/2020. The control group was matched based on the BMI and natural alignment. Comparison of groups was based on postoperative alignment, outlier rate, tibial insert size, lateral bone resection depth, incision-to-wound closure time. All surgeries were performed by a single senior surgeon using the same bi-cruciate stabilizing TKA system. Statistical analysis consisted of parametric t‑testing and Fisher’s exact test with a level of significance of p < 0.05. Results: The two groups showed no differences in mean BMI, natural alignment (p > 0.05) and mean overall limb alignment. No outlier was found for OLA and slope analysis. The smallest insert size (9 mm) was used in 70% of the cases in the revision group (n = 14) and in 90% of the cases in the primary group (n = 18, p = 0.24), distal femoral and tibial resection depth showed no statistical difference (p > 0.05). The incision to wound closure time was longer in the revision group but showed no significant difference. Conclusion: Image-less robotic-assisted revision arthroplasty from UKA to TKA showed a comparable surgery time, and alignment accuracy in comparison to primary robotic-assisted TKA. Comparable bone preservation and subsequent tibial insert size use was observed for both groups.

27 September 2021 in Antibiotics
Verified
Journal Article
Open access
PDF file
LTLars-Rene Tuecking
Lars-Rene Tuecking
JSJulia Silligmann
Julia Silligmann
PSPeter Savov
Peter Savov
MOMohamed Omar
Mohamed Omar
HWHenning Windhagen
Henning Windhagen
Max EttingerMax Ettinger
Max Ettinger
Periprosthetic joint infection (PJI) remains one of the most common causes of revision knee arthroplasty. Controversy continues to surround the proper operative technique of PJI in knee arthroplasty with single- or two-stage replacement. Significant variations are seen in the eradication rates of PJI and in implant survival rates. This detailed retrospective analysis of a single tertiary center is intended to provide further data and insight comparing single- and two-stage revision surgery. A retrospective analysis of all revision total knee arthroplasty (TKA) surgeries from 2013 to 2019 was performed and screened with respect to single- or two-stage TKA revisions. Single- and two-stage revisions were analyzed with regard to implant survival, revision rate, microbiological spectrum, and other typical demographic characteristics. A total of 63 patients were included, with 15 patients undergoing single-stage revision and 48 patients undergoing two-stage revision. The mean follow-up time was 40.7 to 43.7 months. Statistically, no difference was found between both groups in overall survival (54.4% vs. 70.1%, p = 0.68) and implant survival with respect to reinfection (71.4% vs. 82.4%, p = 0.48). Further, high reinfection rates were found for patients with difficult-to-treat organisms and low- to semi-constrained implant types, in comparison to constrained implant types. A statistically comparable revision rate for recurrence of infection could be shown for both groups, although a tendency to higher reinfection rate for single-stage change was evident. The revision rate in this single-center study was comparably high, which could be caused by the high comorbidity and high proportion of difficult-to-treat bacteria in patients at a tertiary center. In this patient population, the expectation of implant survival should be critically discussed with patients.

20 May 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
LTLars-Rene Tuecking
Lars-Rene Tuecking
BEB. Erdle
B. Erdle
ABA. Bernstein
A. Bernstein
POP. Ogon
P. Ogon
MJM. Jaeger
M. Jaeger
DMD. Maier
D. Maier
Background: Horizontal instability following acute acromioclavicular joint (ACJ) reconstruction still occurs with a high prevalence. Although the human acromioclavicular ligament complex (ACLC) represents the major horizontal ACJ stabilizer, experimental studies on healing characteristics are lacking. Therefore, the purpose of this histological study was to investigate the healing potential of the ACLC following acute anatomical reconstruction Methods: In this prospective clinical-experimental study, 28 ACLC biopsies were performed in patients with complete ACJ dislocations (Rockwood type 4 or 5) during acute hook plate stabilization (IG: implantation group; n = 14) and hook plate removal (EG: explantation group; n = 14). Histological analyses included Giemsa staining, polarized light microscopy and immunostaining against CD68, αSMA and collagen type I and type III. Histomorphological evaluation entailed cell counts, collagen expression score, ligament tissue maturity index (LTMI) and descriptive analysis of specific ligamentous structures. Statistics consisted of nonparametric Mann–Whitney U tests and a level of significance of P < .05. Results: Total cell counts (cells/mm2 1491 ± 296 vs. 635 ± 430; P < 0.001) and collagen III expression (3.22 ± 0.22 vs. 1.78 ± 0.41; P < 0.001) were higher in EG compared to IG. Inversely αSMA + (11 ± 9 vs. 179 ± 186; P < 0.001) and CD68 + cell counts (56 ± 20 vs. 100 ± 57; P 0.009) were significantly lower in the EG. The EG revealed a comparable reorientation of ligamentous structures. Consistently, ACLC samples of the EG (21.6 ± 2.4) displayed a high total but differently composed LTMI score (IG: 24.5 ± 1.2; P < 0.001). Conclusions: This experimental study proved the ligamentous healing potential of the human ACLC following acute anatomical reconstruction. Histomorphologically, the ACLC reliably showed a ligamentous state of healing at a mean of about 12 weeks after surgery. However, processes of ligamentous remodeling were still evident. These experimental findings support recent clinical data showing superior horizontal ACJ stability with additional AC stabilization in the context of acute ACJ reconstruction. Though, prospective clinical and biomechanical studies are warranted to evaluate influencing factors on ACLC healing and potential impacts of acute ACLC repair on clinical outcome. Study type: Controlled Laboratory Study

6 March 2020 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
LTLars-Rene Tuecking
Lars-Rene Tuecking
PSP. Savov
P. Savov
TRT. Richter
T. Richter
HWH. Windhagen
H. Windhagen
MEM. Ettinger
M. Ettinger

Verified
Journal Article
Open access
PDF file
PSPeter Savov
Peter Savov
LTLars-Rene Tuecking
Lars-Rene Tuecking
HWHenning Windhagen
Henning Windhagen
Max EttingerMax Ettinger
Max Ettinger
Introduction: Revision total knee arthroplasty after multiple pre-surgeries is challenging. Due to severe bone defects, standard implants for metaphyseal and diaphyseal anchoring may no longer be suitable. The primary aim of this case series is to evaluate the early complication rate for individual knee implants with custom-made cones and stems after two-stage revision with severe bone defects. Methods: Ten patients who were treated with custom-made 3D-printed knee revision implants were included. Inclusion criteria were a two-stage revision due to late-onset or chronic periprosthetic joint infection as well as aseptic loosening. All severe bone defects were AORI type III. All procedure-related complications were evaluated. Postoperative range of motion after one year was measured. The time between the two surgeries was evaluated. Results: The mean follow-up was 21 months (range: 12–40). The mean time between the two-stage surgeries was 71.6 days. No fractures were observed intra- and postoperatively. Two patients were revised without changing metal components due to persistent hematoma (three weeks post-surgery) and persistent PJI (three months post-surgery). The mean passive postoperative range of motion was 92° (range: 80–110°). Conclusions: Individual custom-made implants for rTKA provide a safe procedure for patients with huge bone defects after several pre-surgeries. If standard knee systems with standard cones or sleeves are not suitable anymore, custom-made treatment offers the patient the last option for limb preservation. However, this is associated with increased costs.