Zheyuan Chen

Dr. Zheyuan Chen


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZCZheyuan Chen
Zheyuan Chen
CWChristopher Wright
Christopher Wright
ODOnder Dincel
Onder Dincel
TCTing-Yen Chi
Ting-Yen Chi
Jun KameokaJun Kameoka
Jun Kameoka
For the hundreds of millions of worldwide diabetic patients, glucose test strips are the most important and commonly used tool for monitoring blood glucose levels. Commercial test strips use glucose oxidases as recognition agents, which increases the cost and reduces the durability of test strips. To lower the cost of glucose sensors, we developed a paper-based electrical sensor with molecularly imprinted glucose recognition sites and demonstrated the determination of various glucose concentrations in bovine blood solutions. The sensing electrode is integrated with molecular recognition sites in the conductive polymer. A calibration graph as a function of glucose concentration in aqueous solution was acquired and matched with a correlation coefficient of 0.989. We also demonstrated the determination of the added glucose concentrations ranging from 2.2 to 11.1 mM in bovine blood samples with a linear correlation coefficient of 0.984. This non-enzymatic glucose sensor has the potential to reduce the health care cost of test strips as well as make glucose sensor test strips more accessible to underserved communities.

19 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TCTing-Yen Chi
Ting-Yen Chi
ZCZheyuan Chen
Zheyuan Chen
Jun KameokaJun Kameoka
Jun Kameoka
Perfluorinated compounds like perfluorooctanesulfonic acid (PFOS) are synthetic water pollutants and have accumulated in environments for decades, causing a serious global health issue. Conventional assays rely on liquid chromatography and mass spectroscopy that are very expensive and complicated and thus limit the large-scale monitoring of PFOS in wastewater. To achieve low-cost and accurate detection of PFOS, we designed a paper-based sensor with molecularly imprinted polyaniline electrodes that have recognition sites specific to PFOS. The calibration curve of resistivity ratios as a function of PFOS concentrations has a linear range from 1 to 100 ppt with a coefficient of determination of 0.995. The estimated limit of detection is 1.02 ppt. We also investigated attenuated total reflectance Fourier-transform infrared spectroscopy (ATR-FTIR) and X-ray photoelectron spectroscopy (XPS) spectra of the surface of the polyaniline (PANI) electrodes to propose the potential recognition sites in polyaniline matrix and the detection mechanism. This electrical paper sensor with low cost and excellent sensitivity and selectivity provides the potential for large-scale monitoring of wastewater.

31 August 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
JBJaskirat Batra
Jaskirat Batra
TCTing-Yen Chi
Ting-Yen Chi
MHMo-Fan Huang
Mo-Fan Huang
DZDandan Zhu
Dandan Zhu
ZCZheyuan Chen
Zheyuan Chen
Jun KameokaJun Kameoka
Jun Kameoka
The coronavirus disease (COVID-19) pandemic has increased pressure to develop low-cost, compact, user-friendly, and ubiquitous virus sensors for monitoring infection outbreaks in communities and preventing economic damage resulting from city lockdowns. As proof of concept, we developed a wearable paper-based virus sensor based on a molecular imprinting technique, using a conductive polyaniline (PANI) polymer to detect the lentivirus as a test sample. This sensor detected the lentivirus with a 4181 TU/mL detection limit in liquid and 0.33% to 2.90% detection efficiency in aerosols at distances ranging from 30 cm to 60 cm. For fabrication, a mixture of a PANI monomer solution and virus were polymerized together to form a conductive PANI sensing element on a polyethylene terephthalate (PET) paper substrate. The sensing element exhibited formation of virus recognition sites after the removal of the virus via ultrasound sonication. A dry measurement technique was established that showed aerosol virus detection by the molecularly imprinted sensors within 1.5 h of virus spraying. This was based on the mechanism via which dispensing virus droplets on the PANI sensing element induced hybridization of the virus and molecularly imprinted virus recognition templates in PANI, influencing the conductivity of the PANI film upon drying. Interestingly, the paper-based virus sensor was easily integrated with a wearable face mask for the detection of viruses in aerosols. Since the paper sensor with molecular imprinting of virus recognition sites showed excellent stability in dry conditions for long periods of time, unlike biological reagents, this wearable biosensor will offer an alternative approach to monitoring virus infections in communities.

14 February 2022 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
ZCZheyuan Chen
Zheyuan Chen
TCTing-Yen Chi
Ting-Yen Chi
Jun KameokaJun Kameoka
Jun Kameoka
Methylmalonic acid (MMA) plays a vital role in metabolism and energy production. It has been studied and reported as a sensitive early indicator for mild or serious Vitamin B12 deficiency. The normal range in health people is from 0.00 to 0.40 µM. Thus, most of MMA detection research was focused on Vitamin B12 deficiency with a small detection range. Recently, MMA has been reported to promote tumor progression due to age-induced accumulation. It was found that MMA concentration can reach as high as 80 µM in elderly people. MMA can be of great value as a promising biomarker for cancer diagnostics, as well as a therapeutic target for cancer treatment. Clinical determination of MMA concentration is by the method of gas chromatography mass spectroscopy (GCMS) or liquid chromatography mass spectroscopy (LCMS). However, these methods require extensive sample pre-treatment and large sample volume. They are also expensive and time-consuming. Hence, we proposed an attractive and effective strategy to detect MMA with a broad linear range by a low-cost molecularly imprinted polyaniline paper sensor. The polyaniline paper strip was fabricated by a one-step solution process using MMA as the template by molecular imprinting technology. The concentration of MMA was determined by the resistance change of the paper sensor. A calibration curve as a function of MMA concentration in aqueous solution was acquired with a correlation coefficient of 0.962. We demonstrated detection of the added MMA in plasma with a wide concentration range of 0 to 100 µM with a limit of detection (LoD) of 0.197 µM. This low-cost disposable paper sensor shows great potential in point-of-care MMA detection for cancer prognostics and diagnostics, especially in underserved communities.