Yun-e Zhao

Dr. Yun-e Zhao

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YFYana Fu
Yana Fu
JKJiaojiao Kou
Jiaojiao Kou
DCDongjie Chen
Dongjie Chen
DWDandan Wang
Dandan Wang
YZYinyin Zhao
Yinyin Zhao
YZYun-e Zhao
Yun-e Zhao
To assess the influence of angle kappa (κ) and angle alpha (α) on visual quality after multifocal intraocular lens (IOL) implantation. Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China. Prospective case series. Patients with cataract had phacoemulsification with TECNIS Symfony IOL implantation. The preoperative angle κ and angle α were measured using the iTrace device. Distance, intermediate, and near visual acuities were recorded 3 months postoperatively. The Optical Quality Analyzing System was used to measure the objective scatter index (OSI), modulation transfer function (MTF) cutoff frequency, and Strehl ratio. A patient questionnaire was also administered. The study comprised 29 patients (57 eyes). Monocularly, the mean postoperative logarithm of the minimum angle of resolution (logMAR) uncorrected distance, intermediate, and near visual acuities were 0.03 ± 0.09 (SD), 0.05 ± 0.11, and 0.11 ± 0.09, respectively. The mean postoperative logMAR corrected distance, distance-corrected intermediate, and distance-corrected near visual acuities were -0.01 ± 0.05, 0.04 ± 0.09, and 0.11 ± 0.08, respectively. The mean OSI, MTF cutoff, and Strehl ratio were 1.27 ± 0.84, 32.03 ± 10.80 cycles per degree, and 0.17 ± 0.05, respectively. The OSI (r = 0.398, P = .005), MTF (r = -0.437, P = .002), and Strehl ratio (r = -0.419, P = .003) values were significantly correlated with angle κ. There was no correlation with angle α. Angle κ affected the objective visual quality multifocal after IOL implantation. The decision to implant a multifocal IOL should be carefully considered for patients with a large angle κ.

1 November 2021 in Ophthalmology
Verified
Journal Article
Closed access
PCPingjun Chang
Pingjun Chang
BZBing Zhang
Bing Zhang
LLLi Lin
Li Lin
RCRuru Chen
Ruru Chen
SCSiping Chen
Siping Chen
JQJia Qu
Jia Qu

1 January 2017 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
XLXiaolei Lin
Xiaolei Lin
BXBinbin Xu
Binbin Xu
YZYuxi Zheng
Yuxi Zheng
TCTerry G. Coursey
Terry G. Coursey
YZYinying Zhao
Yinying Zhao
YZYun-e Zhao
Yun-e Zhao
Purpose. To investigate meibomian gland and tear film function in patients with type 2 diabetes.Methods. This prospective study compared changes in meibomian gland and tear film function in type 2 diabetic patients with nondiabetic patients. Meibomian gland function was evaluated by measuring lipid layer thickness (LLT), grading of meibomian gland loss, lid margin abnormalities, and expression of meibum. Tear film function was assessed by measuring tear breakup time (TBUT), the Schirmer I test, noninvasive breakup time (NIBUT), tear meniscus height (TMH), and corneal fluorescein staining.Results. Meibography scores were significantly higher in the diabetic group compared with the nondiabetic group (p=0.004). The number of expressible glands was significantly lower in the diabetic group in temporal, central, and nasal third of the lower eyelid (nasal:p=0.002; central:p=0.040; and temporal:p=0.039). The lid margin abnormality score was significantly higher in the diabetic group than in the nondiabetic group (p=0.04). There was no statistically significant difference in the tear film function parameters between the two groups.Conclusions. Meibomian gland dysfunction (MGD) in type 2 diabetic patients is more severe compared with nondiabetic patients. Overall, most of the diabetic patients manifest as having asymptomatic MGD.

1 July 2018 in The Ocular Surface
Verified
Journal Article
Closed access
YZYinying Zhao
Yinying Zhao
SCSiping Chen
Siping Chen
SWShangrong Wang
Shangrong Wang
YCYan Chen
Yan Chen
JLJunhua Li
Junhua Li
YZYun-e Zhao
Yun-e Zhao

18 January 2021 in Current Eye Research
Verified
Journal Article
Closed access
YCYiqin Chen
Yiqin Chen
JLJunhua Li
Junhua Li
YWYue Wu
Yue Wu
XLXiaolei Lin
Xiaolei Lin
XDXiaohui Deng
Xiaohui Deng
YZYun-e Zhao
Yun-e Zhao
Objective: To determine whether the combination of meibomian gland expression (MGX) with intense-pulsed light (IPL) has a better efficacy to treat meibomian gland dysfunction (MGD) than IPL alone. Methods: One hundred patients with MGD were randomly divided into three groups: MGX, IPL, and IPL+ MGX. Clinical parameters included the Ocular Surface Disease Index (OSDI), tear meniscus height (TMH), noninvasive keratograph tear breakup time (NIBUT), redness, meibomian gland dropout, tear breakup time (TBUT), corneal fluorescent staining (CFS), eyelid margin score, meibomian gland secretion function, and Schirmer I tests were collected before treatment and at 1 and 3 months after treatment. Compare the indexes of each group before and after treatment and also compare the differences of each group on follow-up. Results: Compared to the baseline, OSDI, TBUT, and meibomian gland secretion function in IPL group improved throughout the follow-up period (all P < .05) and part of the meibomian gland secretion function increased continuously. OSDI, TBUT, lower eyelid margin scores, and meibomian gland secretion function in IPL + MGX group improved at the both follow-up visits (all P < .05), and continued improvement in meibomian gland secretion function can be observed. Lower meibomian gland dropout and CFS reduced at 1 month and 3 months respectively in IPL ± MGX group (P = .001,P = .001).Compared to IPL group, only CFS has reduction in IPL + MGX group at 1-month (P < .001), CFS, upper and lower MGYCS were improved at the 3 months (P = .037,P = .014, P = .049). Conclusions: MGX may have synergistic effect when combined with IPL therapy, and the effect can last at least 3 months.

12 October 2018 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
DCDing Chen
Ding Chen
ZLZhangliang Li
Zhangliang Li
JHJinhai Huang
Jinhai Huang
LYLiuqing Yu
Liuqing Yu
SLSongjia Liu
Songjia Liu
YZYun-e Zhao
Yun-e Zhao
Purpose: To quantitate lens nuclear opacity using long-range swept-source optical coherence tomography (SS-OCT) images and to evaluate the correlation of this method to Lens Opacities Classification System III (LOCS III) and a Scheimpflug imaging-based grading system (Pentacam Nuclear Stage function; PNS).Methods: This study enrolled 120 participants (120 eyes) with age-related nuclear cataracts. The best-corrected visual acuity (BCVA), LOCS III nuclear opalescence (NO) and nuclear colour (NC) were obtained. The nuclear density measured using PNS function (NDPNS) was recorded. Three successive series of long-range SS-OCT images were captured, and the nuclear region was analysed using ImageJ (NIH, Bethesda, Maryland, USA) to generate SS-OCT image-based nuclear density (NDSS-OCT). The repeatability of NDSS-OCTmeasurement was evaluated using within-subject coefficient of variation (CVw) and intraclass correlation coefficient (ICC). Correlations of NDSS-OCTwith NO and NC, BCVA and NDPNSwere analysed. According to the integrity of nucleus imaged by Pentacam, patients were divided into two groups, and the parameters were compared between groups.Results: The CVwand ICC for NDSS-OCTmeasurement were 1.5 % and 0.994, respectively. The NDSS-OCTsignificantly correlated with NO (r=0.831), NC (r=0.873), BCVA (r=0.655) and NDPNS(r=0.891). The NDSS-OCT, NO and NC, and BCVA were significantly different between the two groups.Conclusion: Lens nuclear opacity quantitation using long-range SS-OCT images was repeatable and correlated well with LOCS III and PNS function. The Scheimpflug principle had a limitation in imaging dense nucleus. Long-range SS-OCT seems more promising for objectively and quantitatively assessing lens nuclear opacity.