Marco Antonio Rodrigues Torres

Dr. Marco Antonio Rodrigues Torres

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2017 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
EPEugenio Picano
Eugenio Picano
QCQuirino Ciampi
Quirino Ciampi
Rodolfo CitroRodolfo Citro
Rodolfo Citro
Antonello D'AndreaAntonello D'Andrea
Antonello D'Andrea
MSMaria Chiara Scali
Maria Chiara Scali
PCPaolo Colonna
Paolo Colonna
Stress echocardiography (SE) has an established role in evidence-based guidelines, but recently its breadth and variety of applications have extended well beyond coronary artery disease (CAD). We lack a prospective research study of SE applications, in and beyond CAD, also considering a variety of signs in addition to regional wall motion abnormalities. In a prospective, multicenter, international, observational study design, > 100 certified high-volume SE labs (initially from Italy, Brazil, Hungary, and Serbia) will be networked with an organized system of clinical, laboratory and imaging data collection at the time of physical or pharmacological SE, with structured follow-up information. The study is endorsed by the Italian Society of Cardiovascular Echography and organized in 10 subprojects focusing on: contractile reserve for prediction of cardiac resynchronization or medical therapy response; stress B-lines in heart failure; hypertrophic cardiomyopathy; heart failure with preserved ejection fraction; mitral regurgitation after either transcatheter or surgical aortic valve replacement; outdoor SE in extreme physiology; right ventricular contractile reserve in repaired Tetralogy of Fallot; suspected or initial pulmonary arterial hypertension; coronary flow velocity, left ventricular elastance reserve and B-lines in known or suspected CAD; identification of subclinical familial disease in genotype-positive, phenotype- negative healthy relatives of inherited disease (such as hypertrophic cardiomyopathy). We expect to recruit about 10,000 patients over a 5-year period (2016-2020), with sample sizes ranging from 5,000 for coronary flow velocity/ left ventricular elastance/ B-lines in CAD to around 250 for hypertrophic cardiomyopathy or repaired Tetralogy of Fallot. This data-base will allow to investigate technical questions such as feasibility and reproducibility of various SE parameters and to assess their prognostic value in different clinical scenarios. The study will create the cultural, informatic and scientific infrastructure connecting high-volume, accredited SE labs, sharing common criteria of indication, execution, reporting and image storage of SE to obtain original safety, feasibility, and outcome data in evidence-poor diagnostic fields, also outside the established core application of SE in CAD based on regional wall motion abnormalities. The study will standardize procedures, validate emerging signs, and integrate the new information with established knowledge, helping to build a next-generation SE lab without inner walls.

17 August 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
EPEugenio Picano
Eugenio Picano
QCQuirino Ciampi
Quirino Ciampi
LCLauro Cortigiani
Lauro Cortigiani
AAAdelaide M. Arruda-Olson
Adelaide M. Arruda-Olson
Clarissa Borguezan DarosClarissa Borguezan Daros
Clarissa Borguezan Daros
T(The Stress Echo 2030 Study Group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
The Stress Echo 2030 Study Group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
With stress echo (SE) 2020 study, a new standard of practice in stress imaging was developed and disseminated: the ABCDE protocol for functional testing within and beyond CAD. ABCDE protocol was the fruit of SE 2020, and is the seed of SE 2030, which is articulated in 12 projects: 1-SE in coronary artery disease (SECAD); 2-SE in diastolic heart failure (SEDIA); 3-SE in hypertrophic cardiomyopathy (SEHCA); 4-SE post-chest radiotherapy and chemotherapy (SERA); 5-Artificial intelligence SE evaluation (AI-SEE); 6-Environmental stress echocardiography and air pollution (ESTER); 7-SE in repaired Tetralogy of Fallot (SETOF); 8-SE in post-COVID-19 (SECOV); 9: Recovery by stress echo of conventionally unfit donor good hearts (RESURGE); 10-SE for mitral ischemic regurgitation (SEMIR); 11-SE in valvular heart disease (SEVA); 12-SE for coronary vasospasm (SESPASM). The study aims to recruit in the next 5 years (2021–2025) ≥10,000 patients followed for ≥5 years (up to 2030) from ≥20 quality-controlled laboratories from ≥10 countries. In this COVID-19 era of sustainable health care delivery, SE2030 will provide the evidence to finally recommend SE as the optimal and versatile imaging modality for functional testing anywhere, any time, and in any patient.

1 July 1997 in JACC
Verified
Journal Article
Closed access
MTMarco Antonio Rodrigues Torres
Marco Antonio Rodrigues Torres
EPEugenio Picano
Eugenio Picano
GPGuido Parodi
Guido Parodi
RSRosa Sicari
Rosa Sicari
FVFabrizio Veglia
Fabrizio Veglia
OPOberdan Parodi
Oberdan Parodi

24 March 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
QCQuirino Ciampi
Quirino Ciampi
Iacopo OlivottoIacopo Olivotto
Iacopo Olivotto
JPJesus Peteiro
Jesus Peteiro
MDMaria Grazia D’alfonso
Maria Grazia D’alfonso
FMFabio Mori
Fabio Mori
T(the Stress Echo 2020 Study Group on behalf of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
the Stress Echo 2020 Study Group on behalf of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
Background: Sympathetic dysfunction can be evaluated by heart rate reserve (HRR) with exercise test. Objectives: To determine the value of HRR in predicting outcome of patients with hypertrophic cardiomyopathy (HCM). Methods: We enrolled 917 HCM patients (age = 49 ± 15 years, 516 men) assessed with exercise stress echocardiography (ESE) in 11 centres. ESE modality was semi-supine bicycle in 51 patients (6%), upright bicycle in 476 (52%), and treadmill in 390 (42%). During ESE, we assessed left ventricular outflow tract obstruction (LVOTO), stress-induced new regional wall motion abnormalities (RWMA), and HRR (peak/rest heart rate, HR). By selection, all patients completed the follow-up. Mortality was the predetermined outcome measure Results: During ESE, RWMA occurred in 22 patients (2.4%) and LVOTO (≥50 mmHg) in 281 (30.4%). HRR was 1.90 ± 0.40 (lowest quartile ≤ 1.61, highest quartile > 2.13). Higher resting heart rate (odds ratio 1.027, 95% CI: 1.018–1.036, p < 0.001), older age (odds ratio 1.021, 95% CI: 1.009–1.033, p < 0.001), lower exercise tolerance (mets, odds ratio 0.761, 95% CI: 0.708–0.817, p < 0.001) and resting LVOTO (odds ratio 1.504, 95% CI: 1.043–2.170, p = 0.029) predicted a reduced HRR. During a median follow-up of 89 months (interquartile range: 36–145 months), 90 all-cause deaths occurred. At multivariable analysis, lowest quartile HRR (Hazard ratio 2.354, 95% CI 1.116–4.968 p = 0.025) and RWMA (Hazard ratio 3.279, 95% CI 1.441–7.461 p = 0.004) independently predicted death, in addition to age (Hazard ratio 1.064, 95% CI 1.043–1.085 p < 0.001) and maximal wall thickness (Hazard ratio 1.081, 95% CI 1.037–1.128, p < 0.001). Conclusions: A blunted HRR during ESE predicts survival independently of RWMA in HCM patients.

Verified
Journal Article
Open access
PDF file
TBTonino Bombardini
Tonino Bombardini
AZAngela Zagatina
Angela Zagatina
QCQuirino Ciampi
Quirino Ciampi
RARosina Arbucci
Rosina Arbucci
PMPablo Martin Merlo
Pablo Martin Merlo
OIon behalf of the Stress Echo 2020 Study Group of the Italian Society of Cardiovascular Imaging
on behalf of the Stress Echo 2020 Study Group of the Italian Society of Cardiovascular Imaging
Background: Two-dimensional volumetric exercise stress echocardiography (ESE) provides an integrated view of left ventricular (LV) preload reserve through end-diastolic volume (EDV) and LV contractile reserve (LVCR) through end-systolic volume (ESV) changes. Purpose: To assess the dependence of cardiac reserve upon LVCR, EDV, and heart rate (HR) during ESE. Methods: We prospectively performed semi-supine bicycle or treadmill ESE in 1344 patients (age 59.8 ± 11.4 years; ejection fraction = 63 ± 8%) referred for known or suspected coronary artery disease. All patients had negative ESE by wall motion criteria. EDV and ESV were measured by biplane Simpson rule with 2-dimensional echocardiography. Cardiac index reserve was identified by peak-rest value. LVCR was the stress-rest ratio of force (systolic blood pressure by cuff sphygmomanometer/ESV, abnormal values ≤2.0). Preload reserve was defined by an increase in EDV. Cardiac index was calculated as stroke volume index * HR (by EKG). HR reserve (stress/rest ratio) <1.85 identified chronotropic incompetence. Results: Of the 1344 patients, 448 were in the lowest tertile of cardiac index reserve with stress. Of them, 303 (67.6%) achieved HR reserve <1.85; 252 (56.3%) had an abnormal LVCR and 341 (76.1%) a reduction of preload reserve, with 446 patients (99.6%) showing ≥1 abnormality. At binary logistic regression analysis, reduced preload reserve (odds ratio [OR]: 5.610; 95% confidence intervals [CI]: 4.025 to 7.821), chronotropic incompetence (OR: 3.923, 95% CI: 2.915 to 5.279), and abnormal LVCR (OR: 1.579; 95% CI: 1.105 to 2.259) were independently associated with lowest tertile of cardiac index reserve at peak stress. Conclusions: Heart rate assessment and volumetric echocardiography during ESE identify the heterogeneity of hemodynamic phenotypes of impaired chronotropic, preload or LVCR underlying a reduced cardiac reserve.

25 September 2018 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
MSMaria Chiara Scali
Maria Chiara Scali
QCQuirino Ciampi
Quirino Ciampi
EPEugenio Picano
Eugenio Picano
EBEduardo Bossone
Eduardo Bossone
FFFrancesco Ferrara
Francesco Ferrara
CCClara Carpeggiani
Clara Carpeggiani
The effectiveness trial “Stress echo (SE) 2020” evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. To provide web-based upstream quality control and harmonization of B-lines reading criteria. 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module ( http://se2020.altervista.org ). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p < .01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p < .01). Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.