This study assessed the efficacy of percutaneous contrast-enhanced ultrasound (CEUS) in localization sentinel lymph node (SLNs) for biopsy and diagnosis of metastatic SLNs in patients with early breast cancer. From January to November 2017, seventy-five patients with early breast cancer confirmed by pathology were enrolled in this study. CEUS was performed after subdermal injection of ultrasound contrast agent (SonoVue, 2.0 ml in total dose) around the areola on the ipsilateral side of the breast. The contrast-enhanced lymphatic vessels and associated SLNs were observed and traced in real time. The lymphatic vessels and SLN were mapped and labeled on the skin surface. Sentinel lymph node biopsy (SLNB) was performed after injection of 2.0 ml methylene blue at same injection site of SonoVue. The accuracy of percutaneous CEUS localization of SLNs was determined compared to blue dye injection technique. The pathological results under blue dye guided biopsy were used as the reference standard to calculate the sensitivity and specificity of CEUS for the diagnosis of SLNs. A total of 163 SLNs obtained through SLNB following methylene blue tracing in 75 patients. There were 116 SLNs identified by percutaneous CEUS. The difference of detection rates between blue dye and CEUS was statistically significant (Z = −2.651, P = 0.008). The identification rate of SLNs by CEUS was 71.17% (116/163). The accuracy of percutaneous CEUS localization of axillary SLNs was 94.67% (71/75) compared to blue dye-guided biopsy. Among the 116 SLNs detected by percutaneous CEUS, pathologic results showed 51 positive SLNs and 65 negative SLNs whiles CEUS findings indicated 83 positive SLNs and 33 negative SLNs. Only 50 of 83 SLNs had metastasis on pathology, while 33 were detected as false positive. The sensitivity and specificity of CEUS for the diagnosis of metastatic SLN was 98.04%(50/51) and 49.23%(32/65), respectively. Percutaneous CEUS can be used as an effective method to localize the SLNs for guiding SLNB. This method has excellent sensitivity for identifying the SLNs but lower specificity for detecting metastatic SLNs in patients with early stage breast cancer.
1 April 2024 in International Journal of General Medicine
Objective: This study aimed to employ echocardiography for measuring the markers of left ventricular (LV) diastolic function to investigate the effects of family history of gout on the LV diastolic function in patients with primary gout. Methods: Two hundred and eighty-four patients with primary gout who visited the Department of Rheumatology and Immunology of the First Affiliated Hospital of Chengdu Medical College from September 2020 to July 2022 were selected and their family history of gout, general information, and laboratory markers were recorded. Parameters of LV diastolic function were measured via echocardiography. The correlation between family history and LV diastolic function markers was analyzed using univariate and multivariate regression and the receiver operating characteristic (ROC) curve analyses. Results: LV diastolic function parameters, peak early mitral diastolic velocity (E)/peak late mitral diastolic velocity (A), and early septal mitral annulus diastolic motion velocity (Sepe’), early lateral mitral annulus diastolic motion velocity (Late’) and their mean (e’), were significantly lower in patients with familial primary gout, while left atrial volume index (LAVI) and E/e’ were markedly elevated in patients with sporadic primary gout. In patients with family history, the proportion of grade ≥ 2 LV diastolic insufficiency was distinctly higher than that in patients without family history (41.6% vs 12.3%). Even after adjusting for confounding variables, LAVI, E/A, Sepe’, Late’, e’, E/e’ were obviously associated with family history of gout. The area under ROC of family history combined with SUA level for identifying grade ≥ 2 LV diastolic insufficiency in patients with primary gout was 0.872 (P< 0.05). Conclusion: Family history of gout was closely related to echocardiographic LV diastolic function parameters in patients with gout, what is more, family history of gout combined with SUA level was found to be a valuable indicator for discriminating grade ≥ 2 LV diastolic insufficiency in patients with primary gout.
Background: Echocardiographic data investigating the association between left ventricular (LV) function and gout is still limited.Purpose: To analyze the association of echocardiographic parameters based on two-dimentional speckle tracking analysis with clinically related indicators in patients with gout, and to provide a clinical basis for the early diagnosis and treatment of cardiovascular disease in patients with gout.Methods: This study collected gout patients who visited the outpatient and inpatient departments of the first affiliated hospital of chengdu medical college from November 2019 to December 2020. Spearman correlation test was performed to analyze the correlation coefficients between the laboratorial indicators with echocardiographic parameters. And the logistic regression analysis was performed to evaluate the independent effects.Results: The results of multivariate logistic regression showed that fasting plasma glucose (FPG) was a risk factor for the decrease in absolute value of global longitudinal strain [GLS (OR = 2.34; 95% CI, 1.01–5.39; p = 0.04)], Urea was a risk factor for absolute reduction in GCS (OR = 1.40; 95% CI, 1.07–1.85; p = 0.02), age (OR = 1.09, 95% CI, 1.04–1.16; p = 0.001), and hypertension (OR = 8.35; 95% CI, 1.83–38.02; p = 0.006) were risk factors for increased E/Em. High urea levels were significantly related with high risks of LVH (OR = 1.59, 95% CI, 1.04–2.43; p = 0.03) and enlargement of LAVI (OR = 1.68, 95% CI, 1.01–2.80; p = 0.04).Conclusion: Our study found that elevated urea and FPG were risk factors for subclinical LV myocardial dysfunction in patients with gout, which might provide a theoretical basis for the early diagnosis and treatment of heart disease in clinical practice.
1 October 2021 in Ultrasound in Medicine & Biology
This study compared the diagnostic accuracy of percutaneous fistula contrast-enhanced ultrasound (CEUS) combined with 360° 3-D transrectal ultrasound (TRUS) imaging (CEUS + 360°-TRUS) with that of conventional transrectal ultrasound in the diagnosis of complex anal fistulas. A total of 156 patients clinically diagnosed with complex anal fistula from January 2020 to December 2021 were studied and randomly divided into an experimental group (n = 82) and a control group (n = 74). Patients in the experimental group were examined by percutaneous fistula CEUS combined with CEUS + 360°-TRUS, while patients in the control group were examined using TRUS. The detection of fistulas (main tract, branch and internal orifice) and the accuracy of Parks classification were compared between the two groups. Recurrences were followed up at 1, 3 and 6 mo after the surgery. A total of 156 patients were included, aged 23-68 y (average: 37.7 ± 18.2 y). In both groups, the course of disease was 3 mo in 6 cases. A total of 474 fistulas were confirmed by surgery in the aforementioned patients, including 224 main fistulas, 250 branch pipes and 254 internal orifices. The CEUS + 360°-TRUS group had 96.87%, 90.41% and 90.14% diagnostic accuracy for the main tract, branch and internal orifice, which was statistically significant (p < 0.001) compared with the 85.00%, 70.00% and 72.46% for the TRUS group, respectively. The overall accuracy of Parks classification of anal fistula in the CEUS + 360°-TRUS group was significantly higher than that in the TRUS group (90.24% vs. 78.38%, p < 0.001). After 6 mo of follow-up, the recurrence rate in the CEUS + 360°-TRUS group was 4.87%, and the recurrence rate in the TRUS group was 18.91%. Percutaneous fistula CEUS combined with transrectal 360° 3-D imaging has significantly higher accuracy than conventional TRUS in the diagnosis of complex anal fistula, especially for anal fistula branches, internal openings and Parks classification and is beneficial in reducing post-operative occurrence of complex anal fistulas.