Kristin Haugan

Dr. Kristin Haugan


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Injury
Verified
Journal Article
Open access
KHKristin Haugan
Kristin Haugan
JKJomar Klaksvik
Jomar Klaksvik
OFOlav Andreas Foss
Olav Andreas Foss
To compare the Charlson Comorbidity Index (CCI) and American Society of Anesthesiologists (ASA) Physical Status Classification used in two prediction models for 30-day mortality after hip fracture surgery. Data from 3651 patients (mean age: 83 years) from a Norwegian University Hospital were retrospectively obtained and randomly divided into two cohorts: a model cohort (n = 1825) to develop two prediction models with CCI and ASA as the main predictors, and a validation cohort (n = 1826) to assess the predictive ability of both models. A receiver operating characteristic (ROC) curve determined the best model to predict mortality. Area under the ROC curve at 30 days was 0.726 (p = 0.988) for both the CCI- and ASA-model. The chosen cut-off-points on the ROC curve for CCI- and ASA-model corresponded to similar model sensitivities of 0.657 and specificities of 0.680 and 0.679, respectively. Hence, each model predicts correctly 66% (n = 96) of the mortalities and 68% (n = 1132 and n = 1131) of the survivals. 23% (n = 33) of the mortalities were predicted by neither model. The CCI- and ASA-model had equal predictive ability of 30-day mortality after hip fracture. Considering the effort involved in calculating Charlson Comorbidity Index score, the ASA score may be the preferred tool to predict the 30-day mortality after hip fracture.

29 August 2017 in BMJ Open
Verified
Journal Article
Open access
PDF file
KHKristin Haugan
Kristin Haugan
LJLars G Johnsen
Lars G Johnsen
TBTrude Basso
Trude Basso
OFOlav A Foss
Olav A Foss
Objective To compare the efficacies of two pathways—conventional and fast-track care—in patients with hip fracture. Design Retrospective single-centre study. Setting University hospital in middle Norway. Participants 1820 patients aged ≥65 years with hip fracture (intracapsular, intertrochanteric or subtrochanteric). Interventions 788 patients were treated according to conventional care from April 2008 to September 2011, and 1032 patients were treated according to fast-track care from October 2011 to December 2013. Primary and secondary outcome Primary: mortality and readmission to hospital, within 365 days follow-up. Secondary: length of stay. Results We found no statistically significant differences in mortality and readmission rate between patients in the fast-track and conventional care models within 365 days after the initial hospital admission. The conventional care group had a higher, no statistical significant mortality HR of 1.10 (95% CI 0.91 to 1.31, p=0.326) without and 1.16 (95% CI 0.96 to 1.40, p=0.118) with covariate adjustment. Regarding the readmission, the conventional care group sub-HR was 1.02 (95% CI 0.88 to 1.18, p=0.822) without and 0.97 (95% CI 0.83 to 1.12, p=0.644) with adjusting for covariates. Length of stay and time to surgery was statistically significant shorter for patients who received fast-track care, a mean difference of 3.4 days and 6 hours, respectively. There was no statistically significant difference in sex, type of fracture, age or Charlson Comorbidity Index score at baseline between patients in the two pathways. Conclusions There was insufficient evidence to show an impact of fast-track care on mortality and readmission. Length of stay and time to surgery were decreased. Trial registration number NCT00667914; results

3 March 2010 in Journal of Orthopaedics and Traumatology
Verified
Journal Article
Open access
PDF file
OHOtto S. Husby
Otto S. Husby
KHKristin Haugan
Kristin Haugan
PBPål Benum
Pål Benum
OFOlav A. Foss
Olav A. Foss
Background Introduction of new bone cements into clinical practice should include radiostereometric studies. Materials and methods A prospective randomised radiostereometric study was performed, comparing SmartSet HV and Palacos R acrylic bone cements (without antibiotics) using third-generation cementing techniques in primary total hip arthroplasty. Thirty-five patients (36 hips) undergoing Charnley total hip arthroplasty were randomised to receive either of the two cements and were followed with repeated clinical, radiographic and radiostereometric examinations over 24 months. Twenty-seven patients (28 hips) attended 2 years postoperatively. Results The mean distal translation observed was −0.15 mm for SmartSet HV and −0.16 mm for Palacos R. The mean rotation around the longitudinal axis was 0.9° for SmartSet HV and 1.2° for Palacos R. The Merle d’Aubigne Postel score was the maximum of 18 points for all patients in both groups. Conclusions No statistically significant difference in stem fixation with use of SmartSet HV and Palacos R was found at 2-year follow-up.

1 November 2021 in Injury
Verified
Journal Article
Open access
KHKristin Haugan
Kristin Haugan
VHVidar Halsteinli
Vidar Halsteinli
ØDØystein Døhl
Øystein Døhl
TBTrude Basso
Trude Basso
LJLars G. Johnsen
Lars G. Johnsen
OFOlav Andreas Foss
Olav Andreas Foss
To compare costs related to a standardised versus conventional hospital care for older patients after fragility hip fracture and determine whether a shift in hospital care led to cost-shifts between specialists and primary health care. We retrospectively collected and calculated volumes of care and accompanying costs from fracture time until 12 months after hospital discharge for 979 patients. All patients aged ≥ 65 years had fragility hip fractures. The data set had few missing data points because of the patient registry, administrative databases, and a low migration rate. Total costs per patient at 12 months were EUR 78 164 (standard deviation [SD] 58 056) and EUR 78 068 (SD 60 131) for conventional and standardised care, respectively (p = 0.480). Total specialist care costs were significantly lower for the standardised care group (p < 0.001). Total primary care costs were higher for the standardised care group (p = 0.424). Total costs per day of life for the conventional and standardised care groups were EUR 434 and EUR 371, respectively (p = 0.003). Patients in the standardised care group had 17 more days of life. Implementation of a standardised care to improve outcomes for patients with hip fracture caused lower specialist care costs and higher primary care costs, indicating care- and cost-shifts from specialist to primary health care.

10 January 2025 in European Journal of Cancer
Verified
Journal Article
Open access
PBPaula Berstad
Paula Berstad
KHKristin Haugan
Kristin Haugan
MKMarkus D. Knudsen
Markus D. Knudsen
MNMari Nygård
Mari Nygård
RGReza Ghiasvand
Reza Ghiasvand
TRTrude Eid Robsahm
Trude Eid Robsahm
Targeting modifiable factors offers significant potential for primary cancer prevention. For public health strategies, it is essential to quantify the contribution from each factor on a national level. We estimated the contribution of 12 modifiable factors on cancer incidence in the Norwegian population. Nationally representative data (1990-2015) on the prevalence of tobacco smoking, over-exposure to ultraviolet radiation (UVR), alcohol consumption, physical inactivity, overweight and obesity, intake of processed and red meat, fibre and calcium, menopausal hormone therapy (MHT), human papilloma virus (HPV) infection and insufficient breastfeeding were collected from health surveys. Using these prevalences, cancer risk estimates for for the exposures, and average annual cancer incidence rates for 2016-2020, we estimated annual population-attributable fractions (PAFs) and numbers of preventable cases. Of the average 24,608 annual cases of cancers related to our included modifiable factors, 12,12,250 (6240 in women and 6009 in men) (41 %) were attributed to these factors. Tobacco smoking caused the highest proportion of cancers cases, 20 % in men and 13 % in women. Sunburn and indoor tanning caused 13 % and 10 % of cancers in men and women, respectively, and overweight and obesity caused 4.5 % of the cases. Cancers of skin, lung, colon and female breast had the highest number of preventable cases. Over a third of the annual cancer cases in Norway were attributed to 12 modifiable factors. Based on this study, efforts to reduce tobacco smoking, UVR over-exposure, and overweight and obesity could be the most effective in primary prevention of cancer.

30 September 2024 in Acta Orthopaedica
Verified
Journal Article
Open access
PDF file
HJHåkon Greve Johannessen
Håkon Greve Johannessen
GHGeir Hallan
Geir Hallan
TKThomas Kadar
Thomas Kadar
AFAnne Marie Fenstad
Anne Marie Fenstad
SLStein Håkon Låstad Lygre
Stein Håkon Låstad Lygre
OFOve Furnes
Ove Furnes
Background and purpose: We aimed to evaluate polyethylene (PE) wear, cup migration, and clinical outcome over 10 years in total hip arthroplasties (THA) using different articulations.Methods: This is a secondary analysis of 150 patients randomized into 5 groups, using different articulations: Charnley/Charnley Ogee for steel and conventional polyethylene (CPE), or Spectron EF/Reflection with either CPE or highly cross linked polyethylene (XLPE) cups, paired with heads made of either cobalt-chromium (CoCr) or oxidized zirconium (OxZr). All cups were cemented. Patients underwent repeated radiostereometric analysis (RSA) measurements for up to 10 years to assess wear and migration. Clinical outcome was assessed using Harris Hip Score (HHS).Results: After 10 years, the XLPE cups demonstrated low wear rates: 0.08 mm (95% confidence interval [CI] –0.11 to 0.26 mm) with CoCr heads and 0.06 mm (CI –0.14 to 0.26 mm) with OxZr heads, with a mean difference of 0.01 mm (CI –0.26 to 0.29 mm). In contrast, CPE cups exhibited significantly more wear: 1.35 mm (CI 1.16 to 1.55 mm) with CoCr heads and 1.68 mm (CI 1.44 to 1.92 mm) with OxZr heads, with a mean difference of 0.33 mm (CI 0.02 to 0.64 mm). The Charnley/Ogee group (CPE) showed PE wear of 0.34 mm (CI 0.12 to 0.56 mm). The CPE groups with OxZr and CoCr heads had 0.67 mm (CI 0.38 to 0.96 mm) and 0.35 mm (CI 0.09 to 0.61 mm) greater proximal migration respectively than the corresponding XLPE groups. HHS was similar across all groups.Conclusion: We found no significant advantage of OxZr over CoCr heads in reducing wear or migration. XLPE demonstrated a major reduction in wear as well as a reduction in cup migration compared with CPE. Charnley performed better than the other CPE cups in terms of PE wear and cup migration. No differences in clinical outcome were found.