A dc–dc converter used for fuel cell vehicles should be characterized by a wide voltage-gain range and low input current ripple. In order to meet the above requirements, a new nonisolated dc–dc converter consisting of an active switched-inductor cell, a zero current ripple cell, and a switched-capacitor (SC) cell was proposed in this article. The proposed converter integrates with the advantages of a wide voltage-gain range, zero input current ripple, low voltage stresses across power semiconductors, and common ground structure. Thanks to the use of a zero current ripple cell, not only the input current ripple is reduced but also the energy transfer path of the SC cell is changed, thereby reducing the instantaneous peak current of the SC structure. The operating principles, the characteristics analysis, and the parameter design of the proposed converter are given. In addition, to show the merits of the proposed converter, a comparison study is demonstrated. Finally, a prototype of 400 V, 1000 W/50 kHz is developed to validate the effectiveness of the proposed converter.
1 November 2021 in International Journal of Hydrogen Energy
In the fault diagnosis of a wind turbine planetary, the use of multiscale features (MFs) in high scales cannot comprehensively describe fault information. This limitation generally leads to a low fault diagnosis accuracy. Therefore, a fault feature extraction method based on multiscale residual features (MRFs) is proposed. Coarse-grained signals with residual information are obtained through multiscale residual processing. This method initially amplifies the signal dimensions of each scale and enriches fault information. Then, the MRFs are obtained using the relevant feature extraction method. To study the MRP effectiveness, the method is introduced into the spectral feature (SF) and permutation entropy (PE). The multiscale residual SF and multiscale residual PE are obtained. These MRFs are placed in a classifier based on a one-dimensional convolutional neural network to train the diagnostic model. To further enrich the input feature information, the efficient channel attention (ECA)-Stacked ResNet is proposed. The features of each layer are stacked to obtain the multi-channel fault features. Using ECA, the weight of features under each channel is obtained through training to further improve the diagnostic performance of the model. Gearbox fault signals are collected by the Wind Turbine Drivetrain Diagnostics Simulator. The experimental results show that the proposed method can improve the accuracy of the gearbox fault diagnosis and thus has certain engineering application values.
20 July 2022 in IEEE Transactions on Automation Science and Engineering
Effective fault diagnosis can be obtained by using multiblock global orthogonal projections to latent structures (MBGOPLS), but there exist certain limitations in this method in terms of block division intelligence and model robustness to outliers. Although these issues can be addressed by developing correlation analysis, such as mutual information and copula-correlation, the complex coupling relationship between variables has not been fully examined. In this study, a robust MBGOPLS is proposed to intelligently diagnose faults using a relatively stable model. First, a double hierarchical clustering method is established, in which internal hierarchical clustering is performed based on Euclidean distance to discretize the samples. Subsequently, external hierarchical clustering is adopted based on mutual information distance to divide variables into different blocks, which results in intelligent block division while suppressing the influence of outliers. Second, a robust block regression coefficient matrix (BRCM) is obtained by employing joint $\ell _{2,1}$ -norm minimization on the BRCM and prediction error of the correlation between the block input and output. Furthermore, BRCM is integrated into the MBGOPLS framework. Therefore, the proposed method is robust to outliers while retaining the diagnostic properties of MBGOPLS. Finally, the proposed method is applied in a numerical case and an actual thermal power plant. The results verify the method’s applicability and superiority. Note to Practitioners—With increasing large-scale, complex and intelligent to achieve anticipant performance, thermal power plant is prone to faults that can lead to unplanned outages. Meanwhile, complex operation mechanism and environment, and diverse data acquisition sensors make the coupling relationship between variables complex, and collected data often contain numerous outliers, which happens frequently in modern industrial process. Therefore, fault diagnosis is critical to modern industrial process, and the diagnosis accuracy and robustness are the main challenges. This forces us to ensure the block division accuracy and model robustness when using multiblock-based fault diagnosis technology. This paper proposes a robust MBGOPLS to intelligently diagnose faults of thermal power plant using a relatively stable model. Additionally, the proposed method can be extended to fault diagnosis for other large-scale processes.
With the application of unmanned surface vessel (USV) in military and civilian fields, people have put forward higher requirements for the safety and reliability of USV. When the USV fails, its autonomy will be affected, and may cause the USV unable to return back. It is important to accurately detect the faults of USV to ensure their safe operation. In response to the problem of difficult extraction of fault features for USV in complex water conditions, an improved Res2Net multi-scale feature fusion network based on Gramian Angular Field (GAF) is proposed. Firstly, the vibration signal is converted to GAF. Secondly, it is input into the constructed Depthwise Separable Inverted Res2Net residual block (DSIRes2Net) to extract the multiscale features. The multi-scale features are integrated into the low-dimensional features. Finally, these features are put into the Adaptive Time-Frequency feature Fusion block (ATFF) to adaptively fuse the time-domain and frequency-domain features, so as to realize the fault diagnosis of the USV. The experimental results show that the fault diagnosis accuracy of the USV obtained from the proposed algorithm can reach 98.5%, with a variance of 0.17, and a standard deviation of 0.41. The accuracy and stability of the fault diagnosis model have been effectively improved. It provides an important guarantee for the safe operation of the USV.