Tanuj Puri

Dr. Tanuj Puri

Faculty of Biology, Medicine and Health, School of Medical Sciences, Division of Cancer Sciences, The Christie NHS Foundation Trust, Radiotherapy Related Research, Wilmslow Road, Manchester M20 4BX, UK
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2011 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
MSMusib Siddique
Musib Siddique
GBGlen M. Blake
Glen M. Blake
MFMichelle L. Frost
Michelle L. Frost
AMAmelia E. B. Moore
Amelia E. B. Moore
Tanuj PuriTanuj Puri
Tanuj Puri
IFIgnac Fogelman
Ignac Fogelman

1 February 2018 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Closed access
PDF file
Glen BlakeGlen Blake
Glen Blake
Tanuj PuriTanuj Puri
Tanuj Puri
MSMusib Siddique
Musib Siddique
MFMichelle L. Frost
Michelle L. Frost
AMAmelia E. B. Moore
Amelia E. B. Moore
IFIgnac Fogelman
Ignac Fogelman
Dynamic positron emission tomography (PET) imaging with fluorine-18 labelled sodium fluoride ([18F]NaF) allows the quantitative assessment of regional bone formation by measuring the plasma clearance of fluoride to bone at any site in the skeleton. Today, hybrid PET and computed tomography (CT) dual-modality systems (PET/CT) are widely available, and [18F]NaF PET/CT offers a convenient non-invasive method of studying bone formation at the important osteoporotic fracture sites at the hip and spine, as well as sites of pure cortical or trabecular bone. The technique complements conventional measurements of bone turnover using biochemical markers or bone biopsy as a tool to investigate new therapies for osteoporosis, and has a potential role as an early biomarker of treatment efficacy in clinical trials. This article reviews methods of acquiring and analyzing dynamic [18F]NaF PET/CT scan data, and outlines a simplified approach combining venous blood sampling with a series of short (3- to 5-minute) static PET/CT scans acquired at different bed positions to estimate [18F]NaF plasma clearance at multiple sites in the skeleton with just a single injection of tracer.

1 August 2012 in Nuclear Medicine Communications
Verified
Journal Article
Closed access
Glen BlakeGlen Blake
Glen Blake
MSMusib Siddique
Musib Siddique
Tanuj PuriTanuj Puri
Tanuj Puri
MFMichelle Lorraine Frost
Michelle Lorraine Frost
AMAmelia Elizabeth Moore
Amelia Elizabeth Moore
IFIgnac Fogelman
Ignac Fogelman
Purpose We describe a semipopulation input function for evaluating bone plasma clearance from static and dynamic 18F-fluoride PET scans. Methods The semipopulation input function was derived by fitting an exponential curve to venous plasma measurements obtained 30–60 min after injection and adding a population residual curve representing the bolus peak scaled for injected activity and adjusted for time of peak counts. The residual curve was found from nine postmenopausal women who had continuous arterial blood samples and venous samples taken every 10 min. The precision errors of plasma clearance measurements derived from the semipopulation input function using Patlak analysis and the Hawkins compartmental model were compared with the precision errors for four image-derived input functions using data from 20 women who had undergone repeated dynamic PET scans. Results Venous and arterial concentrations were equal by 30 min after injection. The exponential fitted to the 30–60-min venous data accounted for 76% of the total 0–60 min area under the curve, and the SD of the area under the residual curve was 2.6% of the total 0–60 min area under the curve. For Patlak analysis, the precision error (% coefficient of variation) was 13.0% using the semipopulation input function compared with 14.9–21.7% using the four image-derived input functions. For the Hawkins model the equivalent figures were 14.5 and 20.1–30.9%, respectively. Conclusion Accurate and precise measurements of bone plasma clearance were obtained when 18F-fluoride PET scans were analysed using an input function obtained by adding a population residual curve to the exponential obtained from venous blood samples taken 30–60 min after injection.

12 May 2012 in Osteoporosis International
Verified
Journal Article
Closed access
PDF file
Tanuj PuriTanuj Puri
Tanuj Puri
MFM. L. Frost
M. L. Frost
KCKathleen M. Curran
Kathleen M. Curran
MSM. Siddique
M. Siddique
AMA. E. B. Moore
A. E. B. Moore
GBG. M. Blake
G. M. Blake

1 September 2011 in Nuclear Medicine Communications
Verified
Journal Article
Closed access
Tanuj PuriTanuj Puri
Tanuj Puri
GBGlen M. Blake
Glen M. Blake
MFMichelle L. Frost
Michelle L. Frost
AMAmelia E.B. Moore
Amelia E.B. Moore
MSMusib Siddique
Musib Siddique
KCKathleen M. Curran
Kathleen M. Curran
The use of image-derived arterial input functions (IDAIF) for the dynamic quantification of bone metabolism using 18F-fluoride positron emission tomography 18F-PET is an attractive alternative to direct arterial blood sampling. (a) To validate a method for obtaining the IDAIF by imaging the femoral artery against a method for deriving the IDAIF at the aorta that was previously validated against direct arterial sampling. (b) To compare the accuracy of bone plasma clearance measurements (Ki) at the total hip site obtained using the femoral artery IDAIF against Ki values at the same site obtained using the aorta IDAIF. Twelve healthy postmenopausal women with a mean age of 62.6 years (range, 52.3-70.6 years) had 60-min dynamic 18F-PET scans of the lumbar spine and proximal femur 2 weeks apart. The femoral artery IDAIF was obtained from the proximal femur scan using four different algorithms: (a) fixed partial volume correction (PVC) method; (b) variable PVC method; (c) Chen method; and (d) Cook-Lodge method. The aorta IDAIF was obtained from the lumbar spine scan using a previously validated method and the respective Ki values in the hip were used to assess the performance of each of the femoral artery algorithms. When the femoral artery IDAIF methods were compared with the aorta IDAIF in terms of the area under the curve AUC values calculated in 4-min time intervals over 0-60 min, the absolute root mean square errors were: (a) fixed PVC, 0.52; (b) variable PVC, 0.54; (c) Chen, 0.72; and (d) Cook-Lodge, 0.49 in MBq s/ml. There were small, but statistically significant differences, in the Ki values found by all four femoral artery IDAIF methods when compared with the figures obtained using the aorta IDAIF. Bland-Altman plots of Ki values showed the best agreement for the fixed PVC method with a standard deviation of 0.0020 ml/min/ml, followed by variable PVC, Cook-Lodge and Chen method with standard deviations of 0.0022, 0.0024 and 0.0042 ml/min/ml, respectively. We have demonstrated that it is possible to measure regional bone turnover at the hip without the need to perform direct arterial sampling to acquire the arterial input function (AIF). The differences in the Ki values obtained at the hip by using aorta IDAIF and any of the four image-based AIF methods at the femoral artery were small and clinically insignificant. The performance of fixed PVC, variable PVC and Cook-Lodge method was similar although the latter was less robust than the other two methods.

20 September 2017 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
Tanuj PuriTanuj Puri
Tanuj Puri
TGTessa A. Greenhalgh
Tessa A. Greenhalgh
JWJames M. Wilson
James M. Wilson
JFJamie Franklin
Jamie Franklin
LWLia Mun Wang
Lia Mun Wang
TMTim Maughan
Tim Maughan
There is an increasing interest in developing predictive biomarkers of tissue hypoxia using functional imaging for personalised radiotherapy in patients with rectal cancer that are considered for neoadjuvant chemoradiotherapy (CRT). The study explores [18F]fluoromisonidazole ([18F]FMISO) positron emission tomography (PET) scans for predicting clinical response in rectal cancer patients receiving neoadjuvant CRT. Patients with biopsy-proven rectal adenocarcinoma were imaged at 0–45 min, 2 and 4 h, at baseline and after 8–10 fractions of CRT (week 2). The first 6 patients did not receive an enema (the non-enema group) and the last 4 patients received an enema before PET-CT scan (the enema group). [18F]FMISO production failed on 2 occasions. Static PET images at 4 h were analysed using tumour-to-muscle (T:M) SUVmax and tumour-to-blood (T:B) SUVmax. The 0–45 min dynamic PET scans were analysed using Casciari model to report hypoxia and perfusion. Akaike information criteria (AIC) were used to compare data fittings for different pharmacokinetic models. Pathological tumour regression grade was scored using American Joint Committee on Cancer (AJCC) 7.0. Shapiro-Wilk test was used to evaluate the normality of the data. Five out of eleven (5/11) patients were classed as good responders (AJCC 0/1 or good clinical response) and 6/11 as poor responders (AJCC 2/3 or poor clinical response). The median T:M SUVmax was 2.14 (IQR 0.58) at baseline and 1.30 (IQR 0.19) at week 2, and the corresponding median tumour hypoxia volume was 1.08 (IQR 1.31) cm3 and 0 (IQR 0.15) cm3, respectively. The median T:B SUVmax was 2.46 (IQR 1.50) at baseline and 1.61 (IQR 0.14) at week 2, and the corresponding median tumour hypoxia volume was 5.68 (IQR 5.86) cm3 and 0.76 (IQR 0.78) cm3, respectively. For 0–45 min tumour modelling, the median hypoxia was 0.92 (IQR 0.41) min−1 at baseline and 0.70 (IQR 0.10) min−1 at week 2. The median perfusion was 4.10 (IQR 1.71) ml g−1 min−1 at baseline and 2.48 (IQR 3.62) ml g−1 min−1 at week 2. In 9/11 patients with both PET scans, tumour perfusion decreased in non-responders and increased in responders except in one patient. None of the changes in other PET parameters showed any clear trend with clinical outcome. This pilot study with small number of datasets revealed significant challenges in delivery and interpretation of [18F]FMISO PET scans of rectal cancer. There are two principal problems namely spill-in from non-tumour tracer activity from rectal and bladder contents. Emphasis should be made on reducing spill-in effects from the bladder to improve data quality. This preliminary study has shown fundamental difficulties in the interpretation of [18F]FMISO PET scans for rectal cancer, limiting its clinical applicability.