Progress in the development of commercially available non-enzymatic glucose sensors continues to be problematic due to issues regarding selectivity, reproducibility and stability. Overcoming these issues is a research challenge of significant importance. This study reports a novel fabrication process using a double-layer self-assembly of (3 mercaptopropyl)trimethoxysilane (MPTS) on a gold substrate and co-deposition of a platinum–copper alloy. The subsequent electrochemical dealloying of the less noble copper resulted in a nanoporous platinum structure on the uppermost exposed thiol groups. Amperometric responses at 0.4 V vs. Ag/AgCl found the modification to be highly selective towards glucose in the presence of known interferants. The sensor propagated a rapid response time <5 s and exhibited a wide linear range from 1 mM to 18 mM. Additionally, extremely robust stability was attributed to enhanced attachment due to the strong chemisorption between the gold substrate and the exposed thiol of MPTS. Incorporation of metallic nanomaterials using the self-assembly approach was demonstrated to provide a more reproducible and controlled molecular architecture for sensor fabrication. The successful application of the sensor in real blood serum samples displayed a strong correlation with clinically obtained glucose levels.
Monitoring the level of nutrients in soil and their availability for crops can be time-consuming or require expensive instrumentation. This work describes a low-cost (<€500) portable, semi-automated colourimetric orthophosphate (PO43−) analyser supplemented with 3D printed parts. Colour development was based on the phosphomolybdenum blue formation coupled with spectrophotometric detection using a low-cost LED-photodiode assembly. The batch analysis technique required only minimal autonomous additions of reagents to the reaction vessel. In addition, the reaction time was reduced with vigorous automated stirring of the small quantity of reactants. Continuous monitoring of the absorbance throughout the reaction also decreased contact time, eliminating the prerequisite of a blank and warm-up time, customarily associated with colourimetric measurements. The semi-automated Robotic Orthophosphate System (saROS) has a linear dynamic range between 10–750 μg L−1 P-PO43−, and a limit of detection of 3 μg L−1 P-PO43− with good repeatability (RSD of 2.4%). In addition to portability and low cost, the prototype is an accurate and reproducible device for measuring phosphorus in aquatic ecosystems and soil extracts.