Soo-Kyung Kim

Dr. Soo-Kyung Kim

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2019 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
CPChanyong Park
Chanyong Park
HKHong-Rae Kim
Hong-Rae Kim
SKSoo-Kyung Kim
Soo-Kyung Kim
IJIn-Kyung Jeong
In-Kyung Jeong
JPJae-Chul Pyun
Jae-Chul Pyun
Sungsu ParkSungsu Park
Sungsu Park

9 September 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
SKSoo-Kyung Kim
Soo-Kyung Kim
YOYoon-Hee Oh
Yoon-Hee Oh
DKDae-Hyun Ko
Dae-Hyun Ko
HSHeungsup Sung
Heungsup Sung
HOHeung-Bum Oh
Heung-Bum Oh
SHSANG-HYUN HWANG
SANG-HYUN HWANG
Rapid, simple, and inexpensive diagnostic point-of-care tests (POCTs) are essential for controlling infectious diseases in resource-limited settings. In this study, we developed a new detection system based on nanoparticle–DNA aggregation (STat aggregation of tagged DNA, STAT-DNA) to yield a visual change that can be easily detected by the naked eye. This simplified optical detection system was applied to detect hepatitis C virus (HCV). Reverse transcription-polymerase chain reaction (RT-PCR) was performed using primers labeled with biotin and digoxigenin. Streptavidin-coated magnetic particles (1 μm) and anti-digoxigenin antibody-coated polystyrene particles (250–350 nm) were added to form aggregates. The limit of detection (LoD) and analytical specificity were analyzed. The STAT-DNA results were compared with those of the standard real-time PCR assay using serum samples from 54 patients with hepatitis C. We achieved visualization of amplified DNA with the naked eye by adding nanoparticles to the PCR mixture without employing centrifugal force, probe addition, incubation, or dilution. The LoD of STAT-DNA was at least 101 IU/mL. STAT-DNA did not show cross-reactivity with eight viral pathogens. The detection using STAT-DNA was consistent with that using standard real-time PCR.

31 March 2025 in Journal of Medical Internet Research
Verified
Journal Article
Open access
HLHeonyi Lee
Heonyi Lee
YKYi-Jun Kim
Yi-Jun Kim
JKJin-Hong Kim
Jin-Hong Kim
SKSoo-Kyung Kim
Soo-Kyung Kim
TJTae-Dong Jeong
Tae-Dong Jeong
Background: Vancomycin is commonly dosed using standard weight–based methods before dose adjustments are made through therapeutic drug monitoring (TDM). However, variability in initial dosing can lead to suboptimal therapeutic outcomes. A predictive model that personalizes initial dosing based on patient-specific pharmacokinetic factors prior to administration may enhance target attainment and minimize the need for subsequent dose adjustments. Objective: This study aimed to develop and evaluate a machine learning (ML)–based algorithm to predict whether an initial vancomycin dose falls within the therapeutic range of the 24-hour area under the curve to minimum inhibitory concentration, thereby optimizing the initial vancomycin dosage. Methods: A retrospective cohort study was conducted using hospitalized patients who received intravenous vancomycin and underwent pharmacokinetic TDM consultation (n=415). The cohort was randomly divided into training and testing datasets in a 7:3 ratio, and multiple ML techniques were used to develop an algorithm for optimizing initial vancomycin dosing. The optimal algorithm, referred to as the OPTIVAN algorithm, was selected and validated using an external cohort (n=268). We evaluated the performance of 4 ML models: gradient boosting machine, random forest (RF), support vector machine (SVM), and eXtreme gradient boosting (XGB). Additionally, a web-based clinical support tool was developed to facilitate real-time vancomycin TDM application in clinical practice. Results: The SVM algorithm demonstrated the best predictive performance, achieving an area under the receiver operating characteristic curve (AUROC) of 0.832 (95% CI 0.753-0.900) for the training dataset and 0.720 (95% CI 0.654-0.783) for the external validation dataset. The gradient boosting machine followed closely with AUROC scores of 0.802 (95% CI 0.667-0.857) for the training dataset and 0.689 (95% CI 0.596-0.733) for the validation dataset. In contrast, both XGB and RF exhibited relatively lower performance. XGB achieved AUROC values of 0.769 (95% CI 0.671-0.853) for the training set and 0.707 (95% CI 0.644-0.772) for the validation set, while RF recorded AUROC scores of 0.759 (95% CI 0.656-0.846) for the test dataset and 0.693 (95% CI 0.625-0.757) for the external validation set. The SVM model incorporated 7 covariates: age, BMI, glucose, blood urea nitrogen, estimated glomerular filtration rate, hematocrit, and daily dose per body weight. Subgroup analyses demonstrated consistent performance across different patient categories, such as renal function, sex, and BMI. A web-based TDM analysis tool was developed using the OPTIVAN algorithm. Conclusions: The OPTIVAN algorithm represents a significant advancement in personalized initial vancomycin dosing, addressing the limitations of current TDM practices. By optimizing the initial dose, this algorithm may reduce the need for subsequent dosage adjustments. The algorithm’s web-based app is easy to use, making it a practical tool for clinicians. This study highlights the potential of ML to enhance the effectiveness of vancomycin treatment.

8 October 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
MSMin-Kyung So
Min-Kyung So
SPSholhui Park
Sholhui Park
KLKyunghoon Lee
Kyunghoon Lee
SKSoo-Kyung Kim
Soo-Kyung Kim
HCHae-Sun Chung
Hae-Sun Chung
MLMiae Lee
Miae Lee
The spread of delta variants (B.1.671.2) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a severe global threat. Multiplex real-time PCR is a common method for confirming SARS-CoV-2 infection, however, additional tests, such as whole genomic sequencing, are required to reveal the presence or type of viral mutation. Moreover, applying whole genomic sequencing to all SARS-CoV-2 positive samples is challenging due to time and cost constraints. Here, we report that the double or low amplification curve observed during RNA-dependent RNA polymerase (RdRp) gene/S gene amplification in the Allplex SARS-CoV-2 Assay is related to delta/alpha variants. We analyzed the RdRp/S gene amplification curve using 94 samples confirmed as SARS-CoV-2 infection by the Allplex SARS-CoV-2 Assay from January to August, 2021. These positive samples identified variant types using the Novaplex SARS-CoV-2 Variants I and IV Assays. Overall, 17 samples showing a double curve and 11 samples showing a low amplification pattern were associated with alpha-/delta-type strains with variants in the P681 region. The double or low curve shown in the RdRp gene amplification curve had 100% sensitivity and 100% specificity for diagnosing delta/alpha variants. During the SARS-CoV-2 virus diagnostic RT-PCR test using the Allplex SARS-CoV-2 Assay, we could consider the presence of delta/alpha variants in the samples with double or low amplification curve of the RdRp/S gene channel. This PCR amplification curve abnormality enables rapid and cost-effective variant type prediction during SARS-CoV-2 diagnostic testing in clinical laboratories.

28 June 2023 in Clinica Chimica Acta
Verified
Journal Article
Closed access
SKSoo-Kyung Kim
Soo-Kyung Kim
JCJae-Woo Chung
Jae-Woo Chung
JLJinsook Lim
Jinsook Lim
TJTae-Dong Jeong
Tae-Dong Jeong
JCJeonghyun Chang
Jeonghyun Chang
SKSollip Kim
Sollip Kim

17 June 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
HCHae-Sun Chung
Hae-Sun Chung
SKSoo-Kyung Kim
Soo-Kyung Kim
CHChorong Hahm
Chorong Hahm
MLMiae Lee
Miae Lee
Performances of the colistin antimicrobial susceptibility testing (AST) systems of Acinetobacter baumannii vary depending on the manufacturer, and data on colistin-resistant A. baumannii are limited. We evaluated the VITEK2 and Sensititre systems to determine colistin resistance and minimum inhibitory concentration (MIC) for A. baumannii isolated from a clinical microbiology laboratory. A total of 213 clinical A. baumannii isolates were tested, including 81 colistin-resistant A. baumannii. ASTs were performed using the VITEK2 and Sensititre systems according to the manufacturer’s instructions. Reference MICs for colistin were determined using the manual broth microdilution method (BMD). The results of the two AST methods were compared with the BMD results. VITEK2 and Sensititre systems showed category agreements of 95.3% and 99.1%, respectively. VITEK2 had a relatively high very major error (VME) rate (9.9%). Sensititre reported higher MICs than the reference method for the susceptible isolates and showed low essential agreement. In conclusion, the automated systems investigated in this study showed good category agreements for colistin AST of A. baumannii. However, VITEK2 had a high VME rate, and Sensititre had differences in MIC results. Colistin AST remains a challenging task in the clinical laboratory.