BERNARD Lise

Dr. BERNARD Lise

Université Clermont Auvergne, CHU Clermont Ferrand, Clermont Auvergne INP, CNRS, ICCF, F-63000 CLERMONT-FERRAND, France
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2014 in Talanta
Verified
Journal Article
Closed access
BLBERNARD Lise
BERNARD Lise
BDB. Décaudin
B. Décaudin
MLM. Lecoeur
M. Lecoeur
DRD. Richard
D. Richard
DBD. Bourdeaux
D. Bourdeaux
VSV. Sautou
V. Sautou

1 May 2015 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
BLBERNARD Lise
BERNARD Lise
RCR. Cueff
R. Cueff
CBC. Breysse
C. Breysse
BDB. Décaudin
B. Décaudin
VSV. Sautou
V. Sautou

1 October 2015 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
BLBERNARD Lise
BERNARD Lise
RCR. Cueff
R. Cueff
MCMc. Chagnon
Mc. Chagnon
FAF. Abdoulouhab
F. Abdoulouhab
BDB. Décaudin
B. Décaudin
VSV. Sautou
V. Sautou

8 November 2022 in Science of The Total Environment
Verified
Journal Article
Closed access
BLBERNARD Lise
BERNARD Lise
MMMorgane Masse
Morgane Masse
BBBenoît Boeuf
Benoît Boeuf
PCPhilip Chennell
Philip Chennell
BDBertrand Decaudin
Bertrand Decaudin
VSValérie Sautou
Valérie Sautou

23 February 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BLBERNARD Lise
BERNARD Lise
TETeuta Eljezi
Teuta Eljezi
HCHélène Clauson
Hélène Clauson
CLCéline Lambert
Céline Lambert
YBYassine Bouattour
Yassine Bouattour
OGon behalf of the ARMED Study Group
on behalf of the ARMED Study Group
Infusion medical devices (MDs) used in hospitals are often made of plasticized polyvinylchloride (PVC). These plasticizers may leach out into infused solutions during clinical practice, especially during risk-situations, e.g multiple infusions in Intensive Care Units and thus may enter into contact with the patients. The migrability of the plasticizers is dependent of several clinical parameters such as temperature, contact time, nature of the simulant, etc… However, no data is available about the influence of the flow rate at which drug solutions are administrated. In this study, we evaluated the impact of different flow rates on the release of the different plasticizers during an infusion procedure in order to assess if they could expose the patients to more toxic amounts of plasticizers. Migration assays with different PVC infusion sets and extension lines were performed with different flow rates that are used in clinical practice during 1h, 2h, 4h, 8h and 24h, using a lipophilic drug simulant. From a clinical point of view, the results showed that, regardless of the plasticizer, the faster the flow rate, the higher the infused volume and the higher the quantities of plasticizers released, both from infusion sets and extension lines, leading to higher patient exposure. However, physically, there was no significant difference of the migration kinetics linked to the flow rate for a same medical device, reflecting complex interactions between the PVC matrix and the simulant. The migration was especially dependent on the nature and the composition of the medical device.

11 January 2015 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
AGArmed Study Group
Armed Study Group
BLBERNARD Lise
BERNARD Lise
RCRégis Cueff
Régis Cueff
DBDaniel Bourdeaux
Daniel Bourdeaux
CBColette Breysse
Colette Breysse
VSValérie Sautou
Valérie Sautou