Anne Thoustrup Thoustrup Saber

Dr. Anne Thoustrup Thoustrup Saber

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Environmental Toxicology and Pharmacology
Verified
Journal Article
Open access
NHNiels Hadrup
Niels Hadrup
Anne Thoustrup Thoustrup SaberAnne Thoustrup Thoustrup Saber
Anne Thoustrup Thoustrup Saber
ZKZdenka O. Kyjovska
Zdenka O. Kyjovska
NJNicklas R. Jacobsen
Nicklas R. Jacobsen
MVMinnamari Vippola
Minnamari Vippola
UVUlla Vogel
Ulla Vogel
Exposure to metal oxide nanomaterials potentially occurs at the workplace. We investigated the toxicity of two Fe-oxides: Fe2O3 nanoparticles and nanorods; and three MFe2O4 spinels: NiZnFe4O8, ZnFe2O4, and NiFe2O4 nanoparticles. Mice were dosed 14, 43 or 128 μg by intratracheal instillation. Recovery periods were 1, 3, or 28 days. Inflammation - neutrophil influx into bronchoalveolar lavage (BAL) fluid - occurred for Fe2O3 rods (1 day), ZnFe2O4 (1, 3 days), NiFe2O4 (1, 3, 28 days), Fe2O3 (28 days) and NiZnFe4O8 (28 days). Conversion of mass-dose into specific surface-area-dose showed that inflammation correlated with deposited surface area and consequently, all these nanomaterials belong to the so-called low-solubility, low-toxicity class. Increased levels of DNA strand breaks were observed for both Fe2O3 particles and rods, in BAL cells three days post-exposure. To our knowledge, this is, besides magnetite (Fe3O4), the first study of the pulmonary toxicity of MFe2O4 spinel nanomaterials.

11 June 2019 in Particle and Fibre Toxicology
Verified
Journal Article
Open access
PDF file
KBKatja Maria Bendtsen
Katja Maria Bendtsen
ABAnders Brostrøm
Anders Brostrøm
AKAntti Koivisto
Antti Koivisto
IKIsmo Koponen
Ismo Koponen
TBTrine Berthing
Trine Berthing
UVUlla Vogel
Ulla Vogel
Little is known about the exposure levels and adverse health effects of occupational exposure to airplane emissions. Diesel exhaust particles are classified as carcinogenic to humans and jet engines produce potentially similar soot particles. Here, we evaluated the potential occupational exposure risk by analyzing particles from a non-commercial airfield and from the apron of a commercial airport. Toxicity of the collected particles was evaluated alongside NIST standard reference diesel exhaust particles (NIST2975) in terms of acute phase response, pulmonary inflammation, and genotoxicity after single intratracheal instillation in mice. Particle exposure levels were up to 1 mg/m3 at the non-commercial airfield. Particulate matter from the non-commercial airfield air consisted of primary and aggregated soot particles, whereas commercial airport sampling resulted in a more heterogeneous mixture of organic compounds including salt, pollen and soot, reflecting the complex occupational exposure at an apron. The particle contents of polycyclic aromatic hydrocarbons and metals were similar to the content in NIST2975. Mice were exposed to doses 6, 18 and 54 μg alongside carbon black (Printex 90) and NIST2975 and euthanized after 1, 28 or 90 days. Dose-dependent increases in total number of cells, neutrophils, and eosinophils in bronchoalveolar lavage fluid were observed on day 1 post-exposure for all particles. Lymphocytes were increased for all four particle types on 28 days post-exposure as well as for neutrophil influx for jet engine particles and carbon black nanoparticles. Increased Saa3 mRNA levels in lung tissue and increased SAA3 protein levels in plasma were observed on day 1 post-exposure. Increased levels of DNA strand breaks in bronchoalveolar lavage cells and liver tissue were observed for both particles, at single dose levels across doses and time points. Pulmonary exposure of mice to particles collected at two airports induced acute phase response, inflammation, and genotoxicity similar to standard diesel exhaust particles and carbon black nanoparticles, suggesting similar physicochemical properties and toxicity of jet engine particles and diesel exhaust particles. Given this resemblance as well as the dose-response relationship between diesel exhaust exposure and lung cancer, occupational exposure to jet engine emissions at the two airports should be minimized.

17 August 2022 in Toxics
Verified
Journal Article
Open access
PDF file
Henriqueta LouroHenriqueta Louro
Henriqueta Louro
BGBruno Costa Gomes
Bruno Costa Gomes
Anne Thoustrup Thoustrup SaberAnne Thoustrup Thoustrup Saber
Anne Thoustrup Thoustrup Saber
Anna Laura IamiceliAnna Laura Iamiceli
Anna Laura Iamiceli
Thomas GöenThomas Göen
Thomas Göen
MSMaria Joao Silva
Maria Joao Silva
Polycyclic aromatic hydrocarbons (PAHs) are among the chemicals with proven impact on workers’ health. The use of human biomonitoring (HBM) to assess occupational exposure to PAHs has become more common in recent years, but the data generated need an overall view to make them more usable by regulators and policymakers. This comprehensive review, developed under the Human Biomonitoring for Europe (HBM4EU) Initiative, was based on the literature available from 2008–2022, aiming to present and discuss the information on occupational exposure to PAHs, in order to identify the strengths and limitations of exposure and effect biomarkers and the knowledge needs for regulation in the workplace. The most frequently used exposure biomarker is urinary 1-hydroxypyrene (1-OH-PYR), a metabolite of pyrene. As effect biomarkers, those based on the measurement of oxidative stress (urinary 8-oxo-dG adducts) and genotoxicity (blood DNA strand-breaks) are the most common. Overall, a need to advance new harmonized approaches both in data and sample collection and in the use of appropriate biomarkers in occupational studies to obtain reliable and comparable data on PAH exposure in different industrial sectors, was noted. Moreover, the use of effect biomarkers can assist to identify work environments or activities of high risk, thus enabling preventive risk mitigation and management measures.

31 March 2017 in ACS Nano
Verified
Journal Article
Closed access
JBJette Bornholdt
Jette Bornholdt
Anne Thoustrup Thoustrup SaberAnne Thoustrup Thoustrup Saber
Anne Thoustrup Thoustrup Saber
BLBerit Lilje
Berit Lilje
MBMette Boyd
Mette Boyd
MJMette Jørgensen
Mette Jørgensen
ASAlbin Sandelin
Albin Sandelin

22 January 2014 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
CKCarsten Købler
Carsten Købler
Anne Thoustrup Thoustrup SaberAnne Thoustrup Thoustrup Saber
Anne Thoustrup Thoustrup Saber
NJNicklas Raun Jacobsen
Nicklas Raun Jacobsen
HWHåkan Wallin
Håkan Wallin
UVUlla Vogel
Ulla Vogel
KMKristian Mølhave
Kristian Mølhave
Ultrastructural characterisation is important for understanding carbon nanotube (CNT) toxicity and how the CNTs interact with cells and tissues. The standard method for this involves using transmission electron microscopy (TEM). However, in particular, the sample preparation, using a microtome to cut thin sample sections for TEM, can be challenging for investigation of regions with agglomerations of large and stiff CNTs because the CNTs cut with difficulty. As a consequence, the sectioning diamond knife may be damaged and the uncut CNTs are left protruding from the embedded block surface excluding them from TEM analysis. To provide an alternative to ultramicrotomy and subsequent TEM imaging, we studied focused ion beam scanning electron microscopy (FIB-SEM) of CNTs in the lungs of mice, and we evaluated the applicability of the method compared to TEM. FIB-SEM can provide serial section volume imaging not easily obtained with TEM, but it is time-consuming to locate CNTs in the tissue. We demonstrate that protruding CNTs after ultramicrotomy can be used to locate the region of interest, and we present FIB-SEM images of CNTs in lung tissue. FIB-SEM imaging was applied to lung tissue from mice which had been intratracheally instilled with two different multiwalled CNTs; one being short and thin, and the other longer and thicker. FIB-SEM was found to be most suitable for detection of the large CNTs (Ø ca. 70 nm), and to be well suited for studying CNT agglomerates in biological samples which is challenging using standard TEM techniques. 3D FIB-SEM image reconstruction of carbon nanotube (CNT) sample in lung tissue obtained with the double tilted milling method. A few CNTs have manually been traced in the 3D volume, and the white arrowheads point to a single CNT. A – alveole, E – erythrocyte, and P1 – pneumocyte (type 1).

21 November 2019 in Particle and Fibre Toxicology
Verified
Journal Article
Open access
PDF file
Anne Thoustrup Thoustrup SaberAnne Thoustrup Thoustrup Saber
Anne Thoustrup Thoustrup Saber
SPSarah S. Poulsen
Sarah S. Poulsen
NHNiels Hadrup
Niels Hadrup
NJNicklas R. Jacobsen
Nicklas R. Jacobsen
UVUlla Vogel
Ulla Vogel
Recently, Borm and Driscoll published a commentary discussing grouping of Poorly Soluble particles of Low Toxicity (PSLTs) and the use of rats as an animal model for human hazard assessment of PSLTs (Particle and Fibre Toxicology (2019) 16(1):11). The commentary was based on the scientific opinion of several international experts on these topics. The general conclusion from the authors was a cautious approach towards using chronic inhalation studies in rats for human hazard assessment of PSLTs. This was based on evidence of inhibition of particle clearance leading to overload in the rats after high dose exposure, and a suggested over reactivity of rat lung cancer responses compared to human risk.As a response to the commentary, we here discuss evidence from the scientific literature showing that a) diesel exhaust particles, carbon black nanoparticles and TiO2 nanoparticles have similar carcinogenic potential in rats, and induce lung cancer at air concentrations below the air concentrations that inhibit particle clearance in rats, and b) chronic inhalation studies of diesel exhaust particles are less sensitive than epidemiological studies, leading to higher risk estimates for lung cancer. Thus, evidence suggests that the chronic inhalation study in rats can be used for assessing lung cancer risk insoluble nanomaterials.