Having a clear understanding on the phase distribution of gas-liquid two-phase flow through elbow bends is vital in mixing and separation system designs. This paper presents the computational fluid dynamics (CFD) simulations and experimental observations of gas-liquid two-phase flow pattern characteristic through a vertical to horizontal right angled (90°) elbow. Experimental observations were conducted in a transparent test section that consisted of a vertical pipe, elbow bend and horizontal pipe with an inside diameter of 0.036 m. The CFD simulations were performed by using a computer software package, FLUENT 6.2. Bubbly flow conditions were created in the vertical test section with the variation of superficial liquid Reynolds number from 13 497 to 49 488 and volumetric gas quality from 0.05 to 0.2. The CFD results showed a good agreement with experimental results in the following observations. The results showed that gas-liquid flow pattern inside and downstream of the elbow bend mainly depended on liquid velocity and it is also influenced by gas quality at high liquid velocities. At lower liquid velocities, gas-liquid separation began early in the elbow bend and gas-phase migrated to outer bend. Then, it smoothly transformed to stratified flow at elbow outlet. When the liquid velocity was further increased, the liquid phase occupied the outer bend rubbing the gas phase to the inner bend and delayed the formation of gas layer in the horizontal pipe. The increase of gas quality in higher liquid velocities promoted gas core formation at the elbow exit and caused wavy gas layers at the downstream of the elbow.
This is preliminary results of the experimental study about the effect of length of single curtain on the performance of Savonius wind turbine. The curtain arrangement was placed in front of returning blade of the turbine. There are 10 sizes of curtain plate were tested in this study, such as for the width of curtain plate relative to the diameter of rotor blade (SID) of = 1.00, 1.02, 1.03, 1.06, 1.11, 1.15, 1.41, 1.62, 1.83 and 2.00. The experiments are carried out for Reynolds number of 30,000 and 90,000 (based on the characteristic length of d = 2D-b and free stream velocity (U) from fan). The results show that, in general, the placement of the curtain in front of the returning blade of the Savonius wind turbine is more effective for improving turbine performance. This is not necessarily, but depends on the width of the curtain and the number of Reynolds (Re). The results of this experiment show that for the width relative to the turbine diameter of the wider curtain (SID > 1.41) at Re = 90,000, the power coefficient of the turbine with the curtain plate is less than when the turbine without the curtain. Where in this condition, the coefficient of power of the turbine (CP) with the curtain may actually fall to 60.8% of the turbine without curtain, for SID = 1.83 and Re = 90,000.
26 July 2019 in IPTEK The Journal for Technology and Science
Previous research has proven that placing a disruptive cylinder in front of the Savonius wind turbine’s returning blade can significantly increase the performance of the Savonius turbine. In this study, two-dimensional unsteady simulations with a quadratic pave-type structured mesh showed that the circular cylinder placed in front of the returning blade and next to the advancing blade provides the best performance results at a free flow speed of 5 m/s and a Reynolds number of 100,000. In this study, the comparison with experimental data from another study is utilized. The Savonius turbine is installed with an interfering cylinder in front of the returning blade and next to the advancing blade; the air is tighter on the concave side of the advancing blade. The coefficient pressure difference between the convex and concave sides of the blade increases. The maximum moment is achieved in the turbine with a disturbance cylinder at a configuration distance of S/D 1.4 – Y/D 1.61. The maximum moment coefficient is obtained at the position θ = 15°. The placement of two cylinders with a ratio variation of 0.5 D can significantly influence turbine performance. Results show the turbine provides the highest Power Coefficient when TSR = 0.6. The power coefficient increased by 25.11% compared with that of conventional Savonius turbines. Therefore, it can be concluded that the turbine is the optimal configuration for generating the highest power.