A novel chaotropic chromatography method for the quantitative determination of bupropion and its impurities, following analytical quality-by-design (AQbD) principles, is presented. The analytical target profile (ATP) was defined on the basis of the efficient separation and reliable determination of bupropion and its five impurities in tablets. Preliminary experiments revealed the need for the addition of a gradient elution part. A screening fractional factorial experimental design was employed to select the critical method parameters (CMPs) and a Box–Behnken design (BBD) was utilized to investigate their influence on predefined critical method attributes (CMAs). In order to compute the design space (DS), where CMPs meet predefined acceptance limits with a high level of probability (π ≥ 85%), Monte Carlo simulations were performed. The working point selected from the DS corresponded to the following conditions: 37.5% acetonitrile at the start of the gradient program (up to 70% at the end of the gradient program), 45 mM of potassium hexafluorophosphate in the water phase, and the start of the linear gradient step in the gradient program at 10 min. The method was validated according to ICH guidelines and applied to the analysis of Wellbutrin® tablets containing bupropion hydrochloride.
Cetrimide (CE) is a quaternary ammonium compound and a cationic surfactant, which can be used as an antiseptic and preservative in various formulations. Antiseptic solutions of Cetrimide are available in combination with Chlorhexidine Gluconate (CHG) for external use. Chlorhexidine is a biguanide with high microbicidal activity and is widely known as a skin disinfectant. The present work displays the development and validation of an RP-HPLC isocratic method for the simultaneous determination of CE and CHG. The method consists of a Hypersil® SAS C1 (4.6 × 250 mm) 5 μm column, with a mobile phase of 85%/15% v/v MeOH-NaH2PO4·H2O, aqueous solution. In addition, 0.2% of triethylamine (Et3N) was added to the buffer for the confrontation of peak tailing, and then the pH was adjusted to 3.0 with ortho-phosphoric acid (H3PO4). The flow rate was set at 1 mL/min, and adequate detection was achieved with a diode array detector (PDA) at 205 nm. The method was successfully validated according to ICH guidelines for specificity, linearity, accuracy, precision and stability for sample and standard solutions. In addition, the robustness of the method was evaluated through statistical and graphical analysis, using a fractional factorial experimental design.
A simple, precise, and cost-effective reverse phase ion pair chromatographic (RP-IP-HPLC) method was developed and validated for the determination of Ephedrine Hydrochloride in a nasal ointment. A simple and fast extraction protocol was developed for the effective recovery of the analyte, and for this purpose, Bromhexine Hydrochloride was used as the internal standard. The mobile phase consisted of MeOH, Sodium Lauryl Sulfate (SLS) 49.8 mM, triethylamine (ET3N) in the ratio of 65:34.6:0.4%, respectively, with pH = 2.20. The detection of the compounds was carried out at 206 nm, and we used a PDA detector. A short run time was achieved with retention times of 6.3 min and 9.8 min for ephedrine hydrochloride and the internal standard, respectively. The proposed method was validated according to ICH guidelines. Linearity was confirmed in the range of 50–150 μg/mL. Recoveries results were within the range of 98–102% and precision < 2% for the analyte in spiked blank matrix. Robustness testing was conducted via a fractional factorial experimental design. The method was found to fulfill the required specifications for specificity and stability for both standard solutions and samples, as well and applied to the determination of ephedrine hydrochloride in nasal ointments produced by the Greek Military Pharmaceutical Laboratories.
A reversed-phase high-pressure liquid chromatography (RP-HPLC) method was developed and subsequently validated for the simultaneous determination of butamirate citrate (BC) and benzoic acid (BA) in cough syrup. The separation was performed employing a cyanopropyl column with a mobile phase consisting of 50%/50% v/v MeOH/NaH2PO4 * H2O 50 mM aqueous solution pH = 3.0. The quantitation was achieved with a diode array detector (DAD) at 210 nm. The method demonstrated a congenitally satisfactory separation, yet the acquired peaks were asymmetrical. This effect was eliminated by using 1% triethylamine in the buffer solution as a silanol blocker. In addition, the method was found to unequivocally assess the target analytes in the sample matrix and fulfilled the required specifications in relevance to specificity, linearity, accuracy, precision and stability of both the standard solutions and of the sample solutions. Lastly, an experimental design was designed in order to assess the robustness of the proposed assay. To this purpose, a graphical and a statistical approach were utilized and compared to identify the factors that should be strictly controlled during each execution of the method.
Chromatograms with overlapping peaks and a baseline rise or upset constitute a great challenge for analysts. Such a case regarding the analysis of bupropion hydrochloride and its 5 impurities in a tablet formulation was used as a model. A baseline correction technique for liquid chromatography coupled with diode array detection is described by using Rstudio. The asymmetry least squares (ALS) algorithm was used as implemented in the “baseline” package, with parameters lambda and p set to 4 and 0.05, respectively. Peak deconvolution and subsequent integration and area quantification were accomplished through Fytik software. Chromatographic data from the validation procedure were utilized to demonstrate the feasibility of the suggested method and whether this correction affects the outcome of the validation study. Finally, a robustness study was carried out in order to shed light on the factors that have a more significant influence on the baseline correction, showing the reliability of this procedure through random changes in its parameters.
Paracetamol (PAR) and orphenadrine citrate (ORPH) are two active substances commonly used in combination medicinal products, due to the analgesic effect of paracetamol and the muscle relaxant effect of orphenadrine, with a therapeutic indication of mild to moderate acute musculoskeletal pain. The aim of this work is to develop and validate an isocratic HPLC method for the simultaneous determination of PAR and ORPH in tablet formulation. Preliminary experiments showed that an analytical column with a chemically bound phenyl phase was required. A Box–Behnken design (BBD) was utilized to optimize the analytical method for two key responses, PAR asymmetry factor (AsymPAR) and ORPH capacity factor (kORPH), with three numerical factors: percentage of ACN in mobile phase (A); pH (B); and salt concentration in the aqueous solution (C). The optimized method consists of a Pinnacle DB Biphenyl (250 × 4.6 mm) 5 µm column, and a mobile phase of 37%/63% v/v ACN-NaH2PO4·H2O in 29 mM aqueous solution, pH = 2.5. The flow rate was set to 1.5 mL/min and detection occurred at 215 nm. After the optimization process the following chromatographic conditions were selected and the method was validated for various ICH parameters covering system suitability, specificity, linearity (R2 = 1.00), precision (%RSD ≤ 2), accuracy (98% ≤ %Recovery ≤ 102%), and robustness. Finally, the environmental friendliness of the novel method was assessed by using the Analytical GREEnness (AGREE) metric tool, obtaining a score of 0.67.