To appraise the dosimetric features and the quality of the treatment plan for radiosurgery of multiple brain metastases optimized with a novel automated engine and to compare with plans optimized for robotic-based delivery. A set of 15 patients with multiple brain metastases was selected for this in silico study. The technique under investigation is the recently introduced HyperArc. For all patients, three treatment plans were computed and compared: i: a HyperArc; ii: a standard VMAT; iii) a CyberKnife. Dosimetric features were computed for the clinical target volumes as well as for the healthy brain tissue and the organs at risk. The data showed that the best dose homogeneity was achieved with the VMAT technique. HyperArc allowed to minimize the volume of brain receiving 4Gy (as well as for the mean dose and the volume receiving 12Gy, although not statistically significant). The smallest dose on 1 cm3 volume for all organs at risk is for CK techniques, and the biggest for VMAT (p < 0.05). The Radiation Planning Index coefficient indicates that, there are no significant differences among the techniques investigated, suggesting an equivalence among these. At treatment planning level, the study demonstrates that the use of HyperArc technique can significantly improve the sparing of the healthy brain while maintaining a full coverage of the target volumes.
The study is focused on correlation of isotherms derived from thermal images with an isodoses describing treatment plan for patients with breast cancer treated by radiotherapy. The irradiated area covered the part of the body after mastectomy. The study included patients diagnosed with breast cancer who were qualified for radiotherapy treatment. All patients were monitored during each treatment week during the entire radiotherapy process. The measurements were made under strictly defined conditions. In the treatment planning system (TPS), the specific plan was created for each patient. Spatial dose distribution in the patient’s body was obtained and presented by the isodoses (lines connecting points with the same dose values). The following areas from the treatment planning system were plotted on the thermograms: target (tumor area) and isodose: 45 Gy, 40 Gy, 30 Gy, 20 Gy and 10 Gy. The obtained results indicated a high correlation between magnitude of the dose represented as the isodose and the temperature of the treated skin. Moreover, preliminary analysis showed a repeatable increase of the mean temperature in the irradiated area during the treatment.
1 January 2021 in Journal of Applied Clinical Medical Physics
The accuracy of radiotherapy is the subject of continuous discussion, and dosimetry methods, particularly in dynamic techniques, are being developed. At the same time, many oncology centers develop quality procedures, including pretreatment and online dose verification and proper patient tracking methods. This work aims to present the possibility of using portal dosimetry in the assessment of radiotherapy repeatability. The analysis was conducted on 74 cases treated with dynamic techniques. Transit dosimetry was made for each collision-free radiation beam. It allowed the comparison of summary fluence maps, obtained for fractions with the corresponding summary maps from all other treatment fractions. For evaluation of the compatibility in the fluence map pairs (6798), the gamma coefficient was calculated. The results were considered in four groups, depending on the used radiotherapy technique: stereotactic fractionated radiotherapy, breath-hold, free-breathing, and conventionally fractionated other cases. The chi(2) or Fisher's exact test was made depending on the size of the analyzed set and also Mann-Whitney U-test was used to compare treatment repeatability of different techniques. The aim was to test whether the null hypothesis of error-free therapy was met. The patient is treated repeatedly if the P-value in all the fluence maps sets is higher than the level of 0.01. The best compatibility between treatment fractions was obtained for the stereotactic technique. The technique with breath-holding gave the lowest percentage of compliance of the analyzed fluence pairs. The results indicate that the repeatability of the treatment is associated with the radiotherapy technique. Treated volume location is also an essential factor found in the evaluation of treatment accuracy. The EPID device is a useful tool in assessing the repeatability of radiotherapy. The proposed method of fluence maps comparison also allows us to assess in which therapeutic session the patient was treated differently from the other fractions.
The aim of the study was to evaluate the temperature parameter of the breast area in patients undergoing radiotherapy at various intervals. The relationship between temperature changes on the patient’s skin and the time after the end of radiotherapy was studied. Measurements with a thermal imaging camera were performed in a group of twelve volunteers. Six of them were healthy women who did not have thermal asymmetry between the breasts, whereas six were diagnosed with breast cancer and underwent mastectomy due to the advanced stage of the disease. The patients were qualified for radiation therapy. Thermographic examinations were performed before treatment, two months later and then six months after the end of the treatment. Temperature differences between the healthy breasts and the treated areas were assessed. Additionally, the correlation between a patient’s skin temperature changes and the time after the end of radiotherapy was analyzed. The highest skin temperature increase (1.47 °C) was observed 6 months after the end of RT compared to the measurement before treatment. It seems that thermovision may bring a new tool for quantitative analyses of the temperature effects of radiotherapy.
The aim of the study was to assess the usefulness of the infrared thermography method in the assessment of the body’s thermal reaction in patients during radiotherapy. Studies have shown how the temperature distribution changes with the dose of radiation used in each treatment week. Fifty-four patients participated in the study. The control group consisted of healthy patients, among whom the difference in mean temperatures between the breasts was checked. The study group included patients after conserving procedures qualified for radiotherapy. Measurements were taken and analyzed for each patient during each week of treatment. The target area (marked by a doctor) and the 30 Gy, 20 Gy and 10 Gy isodoses (generated from the treatment plan) were transferred on thermograms and then analyzed. This way of defining the observed areas is the most accurate and individually adjusted to each treated patient. The analysis showed an increase in temperature in the tested body surface areas, whereas the highest average temperature value was achieved during the third week of treatment. The observations may be used to evaluate the skin reaction from radiation; however, they require further studies and new quantitative parameters.
Purpose: Results of the low-dose radiation therapy (LDRT) in patients with pneumonia due to COVID-19 has been presented. Methods: Fifteen patients received a single-fraction radiation dose of 1 Gy to the bilateral lungs due to pre-ARDS pneumonia in the course of COVID-19. Follow-up was performed on days 1, 3, 5, 7, 14 after LDRT. Results: Eleven patients (73%) were released up until day 28. Median hospitalization was 20 days; 28-day mortality was 13%. Median O2 saturation improved within 24 h after LDRT in 14/15, with median SpO2 values of 84.5% vs. 87.5% p = 0.016, respectively. At day 14 of hospitalization, 46% did not require oxygen supplementation. Significant decline in CRP and IL-6 was observed within 24 h post LDRT. No organ toxicities were noted. Conclusion: LDRT is feasible, well tolerated and may translate to early clinical recovery in patients with severe pneumonia. Further studies are needed to determine optimal candidate, time and dose of LDRT for COVID-19 patients with pneumonia.