New monolithic multi-layered zirconia restorations are gaining popularity due to their excellent aesthetic properties. However, current knowledge of these newest multi-layer ceramics in terms of mechanical properties is scarce. Three monolithic, multi-layered zirconia materials (Katana, Kuraray Noritake, Japan) were selected for comparison: High Translucent Multi-layered zirconia (HTML), Super Translucent Multi-layered zirconia (STML) and Ultra Translucent Multi-layered zirconia (UTML). Fifteen specimens per group were cut from pre-sintered blocs in each of the four layers (L1, L2, L3, L4) and in different thicknesses (0.4 mm, 0.8 mm and 1.2 mm). Critical fracture load (Fcf) was recorded in 3-point-bending. Flexural strength (σ) in MPa, Vickers hardness (HV) in N/mm2, fracture toughness (KIc) in MPa*m1/2, Weibull Modulus (m) and characteristic Weibull strength (σw) in MPa were assessed. Statistical analysis was performed using ANOVA analysis. FS and KIc were significantly higher (p < 0.05) for Katana™ HTML (652.85 ± 143.76–887.64 ± 118.95/4.25 ± 0.43–5.01 ± 0.81) in comparison to Katana™ STML (280.17 ± 83.41–435.95 ± 73.58/3.06 ± 0.27–3.84 ± 0.47) and UTML (258.25 ± 109.98–331.26 ± 56.86/2.35 ± 0.31–2.94 ± 0.33), with no significant differences between layers and layer thicknesses. The range of indications should be carefully considered when selecting the type of monolithic zirconia for fabrication of dental restorations, as materials widely differ in mechanical properties.
17 December 2022 in The Journal of Prosthetic Dentistry
For restoration of extensively damaged teeth preprosthetic treatment measures are necessary. Crown lengthening and extrusion affect the prospective crown-root ratio (CRR). The subject of this in vitro study was to compute CRRs for both treatment approaches. 120 human maxillary central extracted incisors were measured. Measurements were calculated for five treatment groups: C (control), E-2 mm (extrusion of 2 mm), E-4 mm (extrusion of 4 mm), CL-2 mm (crown lengthening of 2 mm), and CL-4 mm (crown lengthening of 4 mm). Tooth (TL), root (RL), and crown lengths (CL) were measured from mesial (m) and facial (f) cemento-enamel junction (CEJ), and respective anatomic (CRR) and effective crown-root ratios (eCRR) were calculated. Following CRR values were computed for C: CRR-m = 0.4 ± 0.1, CRR-f = 0.7 ± 0.1. All crown-root ratios were lower (more favourable) for extrusion compared to crown lengthening (p < 0.001). ECRRs were higher than anatomic CRRs. CRR at mesial CEJ was significantly lower than CRR with facial CEJ as reference (p < 0.001). Mesial measurement-based calculations of CRR typically based on radiographic images should be interpreted with caution as they underestimate the eCRR. CRR can be expected as lower, i.e. more favourable, when teeth are extruded than crown lengthened.
Aims: This in silico study aimed to investigate the effect of implant–abutment contact surfaces on the stress generation of Morse taper implants under oblique loading. Materials and methods: Three-dimensional finite element models of Bone-Level and Tissue-Level implants were simulated with Standard and Partial contacts between the abutment and implant. The dimensional parameters followed the ISO 14801 guidelines, and an oblique load of 300 N was applied to the implants. The von Mises stress was acquired. Results: The Tissue-Level design showed a significant difference in the stress level when the connection with the implant, abutment, and screw was Partial. For the implant fixture, abutment, and screw, the Tissue-Level design showed 13% more stress in the implant, abutment, and screw when the connection was Partial. The Bone-Level design did not affect the connection and showed an overall 42% lower stress than the Tissue-Level design for the implant fixture. However, in the screw, there was a difference between the Bone-Level implants with a Standard and Partial connection. In contrast, for the Tissue-Level implant, this difference was less evident with higher stress peaks in the entire set. Conclusion: To achieve optimal outcomes, it is highly recommended to use original abutments, as they provide a more precise fit. The stress peaks were notably lower in Bone-Level implants compared to Tissue-Level implants. Furthermore, an implant–abutment connection with more contacting areas significantly reduced stress concentration, especially in Tissue-Level implant designs. By choosing well-fitting abutments, one can ensure more stable and durable implant performance with less stress.