Laurent Auboire

Laurent Auboire


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2016 in Expert Opinion on Drug Delivery
Verified
Journal Article
Closed access
CSCharles A. Sennoga
Charles A. Sennoga
EKEmma Kanbar
Emma Kanbar
LALaurent Auboire
Laurent Auboire
PDPaul-Armand Dujardin
Paul-Armand Dujardin
DFDamien Fouan
Damien Fouan
ABAyache Bouakaz
Ayache Bouakaz
Introduction: Recent developments in ultrasound imaging and ultrasound contrast agents (UCAs) improved diagnostic confidence in echography and set into motion their combined use as a tool for drug delivery and therapeutic monitoring. Non-invasive, precise and targeted delivery of drug molecules to pathological tissues by employing different mechanisms of drug release is becoming feasible. Areas covered: We sought to describe: the nature and features of UCAs; outline current contrast-specific imaging modes; before describing a variety of strategies for using ultrasound and microbubbles as a drug delivery system. Our expert opinion focusses on results and prospects of using ultrasound and microbubbles as a dual modality for drug delivery and therapeutic monitoring. Expert opinion: Today, ultrasound and microbubbles present a realistic prospect as drug delivery tools that have been demonstrated in a variety of animal models and clinical indications. Besides delivering drugs, ultrasound and microbubbles have demonstrated added value through therapeutic monitoring and assessment. Successful evaluation of the sonoporation mechanism(s), ultrasound parameters, drug type and dose will need to be addressed before translating this technology for clinic use. Ultimately, the development of a strategy for monitoring targeted delivery and its implementation in clinical practice would advance therapeutic treatment to a new qualitative level.

8 February 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LALaurent Auboire
Laurent Auboire
CSCharles A Sennoga
Charles A Sennoga
JHJean-Marc Hyvelin
Jean-Marc Hyvelin
FOFréderic Ossant
Fréderic Ossant
Jean-Michel EscoffreJean-Michel Escoffre
Jean-Michel Escoffre
ABAyache Bouakaz
Ayache Bouakaz
Microbubbles (MBs) combined with ultrasound sonothrombolysis (STL) appears to be an alternative therapeutic strategy for acute ischemic stroke (IS), but clinical results remain controversial. The aim of this systematic review is to identify the parameters tested; to assess evidence on the safety and efficacy on preclinical data on STL; and to assess the validity and publication bias. Pubmed® and Web of ScienceTM databases were systematically searched from January 1995 to April 2017 in French and English. We included studies evaluating STL on animal stroke model. This systematic review was conducted in accordance with the PRISMA guidelines. Data were extracted following a pre-defined schedule by two of the authors. The CAMARADES criteria were used for quality assessment. A narrative synthesis was conducted. Sixteen studies met the inclusion criteria. The result showed that ultrasound parameters and types of MBs were heterogeneous among studies. Numerous positive outcomes on efficacy were found, but only four studies demonstrated superiority of STL versus recombinant tissue-type plasminogen activator on clinical criteria. Data available on safety are limited. Quality assessment of the studies reviewed revealed a number of biases. Further in vivo studies are needed to demonstrate a better efficacy and safety of STL compared to currently approved therapeutic options. http://syrf.org.uk/protocols/

26 September 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
LALaurent Auboire
Laurent Auboire
DFDamien Fouan
Damien Fouan
JGJean-Marc Grégoire
Jean-Marc Grégoire
FOFréderic Ossant
Fréderic Ossant
CPCamille Plag
Camille Plag
ABAyache Bouakaz
Ayache Bouakaz
Stroke is the second leading cause of death worldwide. Existing therapies present limitations, and other therapeutic alternatives are sought, such as sonothrombolysis with microbubbles (STL). The aim of this study was to evaluate the change induced by STL with or without recombinant tissue-type plasminogen activator (rtPA) on the acoustic and elastic properties of the blood clot by measuring its sound speed (SoS) and shear wave speed (SWS) with high frequency ultrasound and ultrafast imaging, respectively. An in-vitro setup was used and human blood clots were submitted to a combination of microbubbles and rtPA. The results demonstrate that STL induces a raise of SoS in the blood clot, specifically when combined with rtPA (p < 0.05). Moreover, the combination of rtPA and STL induces a hardening of the clot in comparison to rtPA alone (p < 0.05). This is the first assessment of acoustoelastic properties of blood clots during STL. The combination of rtPA and STL induce SoS and hardening of the clot, which is known to impair the penetration of thrombolytic drugs and their efficacy.

1 November 2016 in International Journal of Cardiology
Verified
Journal Article
Closed access
LALaurent Auboire
Laurent Auboire
JAJoachim Alexandre
Joachim Alexandre
VBValentina Boccadamo
Valentina Boccadamo
CLCécile Labbé
Cécile Labbé

24 July 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LALaurent Auboire
Laurent Auboire
Jean-Michel EscoffreJean-Michel Escoffre
Jean-Michel Escoffre
DFDamien Fouan
Damien Fouan
JJJean-René Jacquet
Jean-René Jacquet
FOFrédéric Ossant
Frédéric Ossant
ABAyache Bouakaz
Ayache Bouakaz
Thrombosis is a major cause of several diseases, i.e. myocardial infarction, cerebral stroke and pulmonary embolism. Thrombolytic therapies are required to induce fast and efficient recanalization of occluded vessels. To evaluate the in vitro efficacy of these thrombolytic strategies, measuring clot dissolution is essential. This study aimed to evaluate and validate high resolution ultrasound as a tool to assess the exact volume of clots in 3D and in real time during in vitro thrombolytic drug testing. This new method was validated by measuring the effects of concentration range of recombinant tissue type plasminogen activator on a blood clot during complete occlusion or 70% stenosis of a vessel. This study shows that high resolution ultrasound imaging allows for a real-time assessment of the 3D volume of a blood clot with negligible inter- and intra-operator variabilities. The conclusions drawn from this study demonstrate the promising potential of high resolution ultrasound imaging for the in vitro assessment of new thrombolytic drugs.

2 March 2021 in Journal of Thrombosis and Haemostasis
Verified
Journal Article
Closed access
PDF file
LALaurent Auboire
Laurent Auboire