A review of the first 4000 reports to the webAIRS anaesthesia incident reporting database was performed to analyse cases reported as difficult or failed intubation. Patient, task, caregiver and system factors were evaluated. Among the 4000 reports, there were 170 incidents of difficult or failed intubation. Difficult or failed intubation incidents were most common in the 40–59 years age group. More than half of cases were not predicted. A total of 40% involved patients with a body mass index >30 kg/m 2 and 41% involved emergency cases. A third of the reports described multiple intubation attempts. Of the reports, 18% mentioned equipment problems including endotracheal tube cuff rupture, laryngoscope light failure, dysfunctional capnography and delays with availability of additional equipment to assist with intubation. Immediate outcomes included 40 cases of oxygen desaturation below 85%; of these cases, four required cardiopulmonary resuscitation. The majority of the incidents resulted in no harm or minor harm (45%). However, 12% suffered moderate harm, 3.5% severe harm and there were three deaths (although only one related to the airway incident). Despite advances and significant developments in airway management strategies, difficult and failed intubation still occurs. Although not all incidents are predictable, nor are all preventable, the information provided by this analysis might assist with future planning, preparation and management of difficult intubation.
1 May 2019 in International Journal of Obstetric Anesthesia
Correct intracuff pressure of endotracheal tubes and supraglottic airway devices is required to avoid complications such as sore throat, dysphagia and dysphonia, while maintaining an adequate airway seal. However, intracuff pressure monitoring of airway devices during general anaesthesia may not receive the attention it deserves. The aim of this survey was to investigate the current practice regarding intraoperative cuff pressure monitoring in hospitals across Australia and New Zealand. An online ten-question survey was disseminated by the Australian and New Zealand College of Anaesthetists Clinical Trials Network to a randomised selection of 1000 Australian and New Zealand College of Anaesthetists Fellows working in private and public hospitals of varying sizes. There were 305 respondents in total, but not all respondents answered all questions. In total, 67 of 304 respondents (22.0%) did not have access to a cuff pressure manometer at their main site of work, and of these, 30 (9.9%) expressed that they would like access to one in their daily practice. Of 288 respondents, 122 (40.0%) reported that they used cuff pressure monitoring as part of their routine practice, but 95 (33.0%) measured the cuff pressure at induction only. For supraglottic airway devices, only 44 of 250 respondents (17.6%) aimed for a cuff pressure of 40–60 cmH 2 O. Of 255 respondents, 101 (39.6%) aimed for a cuff pressure of 20–30 cmH 2 O for endotracheal tubes. These findings indicate that educational programmes are required to increase the availability and use of cuff pressure monitoring devices for both endotracheal tubes and supraglottic airway devices across Australia and New Zealand.