The performance of air conditioning systems deteriorate due to the natural aging and wear caused by operating the devices. This is termed “aging degradation,” and it results from a lack of appropriate maintenance which accelerates the degree of performance degradation. The performance degradation of an air conditioning system can cause problems such as increased energy consumption, deteriorated indoor heating environment, and shortened lifespan of air conditioning equipment. To prevent such problems, it is important to establish a long-term maintenance plan to recover degraded performance, such as predicting an appropriate maintenance time by identifying the real-time performance degradation rate based on a system’s operation data. In this study, the performance degradation rate, according to the operating time, was estimated using long-term operation data for devices constituting a heat source system, and the effect of performance degradation of the heat source system’s operation and energy consumption was reviewed using a simulation. The performance degradation rate of the target device was estimated by analyzing the variation trend of the calibration coefficient, which was calculated when the initial performance prediction model was calibrated through operating data. Using this approach, it was confirmed that the annual performance degradation rate was 1.0–1.4% for the heat source equipment, 0.4–1.2% for the cooling towers, and 0.8–1.3% for the pumps. In addition, a heat source system energy simulation calculated the 15-year performance degradation of the heat source equipment to be 34–52% and 7–19% for both the cooling towers and pumps. Due to the equipment performance deterioration, the number of operating heat source equipment and cooling tower fans, and the pump flow rate gradually increased every year, thus accelerating the performance deterioration even further. As a result, energy consumption in the 15th year increased by approximately 41% compared with the initial energy consumption.
11 July 2014 in Journal of Central South University
A sliding mode control (SMC) technique based on a state observer with a Kalman filter and feedforward controller was established for a variable-speed refrigeration system (VSRS) to ensure robust control against model uncertainties and disturbances, including noise. The SMC was designed using a state-space model transformed from a practical transfer function model, which was derived by conducting dynamic characteristic experiments. Fewer parameters affecting the model uncertainty were required to be identified, which facilitated modeling. The state observer for estimating the state variables was designed using a Kalman filter to ensure robustness against noise. A feedforward controller was added to the control system to compensate for the deterioration in the transient characteristics due to the saturation function used to avoid chattering. A genetic algorithm was used to alleviate the trial and error involved in determining the design parameters of the saturation function and select optimal values. Simulations and experiments were conducted to verify the control performance of the proposed SMC. The results show that the proposed controller can realize robust temperature control for a VSRS despite stepwise changes in the reference and external heat load, and avoid the trial and error process to design parameters for the saturation function.