Yu-Feng Chen

Dr. Yu-Feng Chen

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2017 in Maxillofacial Plastic and Reconstructive Surgery
Verified
Journal Article
Open access
PDF file
SHSung Ok Hong
Sung Ok Hong
YCYu-Feng Chen
Yu-Feng Chen
JJJunho Jung
Junho Jung
YKYong-Dae Kwon
Yong-Dae Kwon
SLStanley Yung Liu
Stanley Yung Liu
The prevalence of obstructive sleep apnea (OSA) is estimated to be 1–5% of the adult population world-wide, and in Korea, it is reported at 4.5% of men and 3.2% of women (Age 40 to 69 years old). Active treatment of OSA is associated with decrease in insulin resistance, cardiovascular disease, psychosocial problems, and mortality. Surgical treatment of OSA has evolved in the era of neuromodulation with the advent of hypoglossal nerve stimulation (HGNS). We share this review of HGNS with our maxillofacial surgical colleagues to expand the scope of surgical care for OSA.

1 January 2022 in Dental Materials
Verified
Journal Article
Open access
TLTing-Hsun Lan
Ting-Hsun Lan
PCPing-Ho Chen
Ping-Ho Chen
AFAlex Fok
Alex Fok
YCYu-Feng Chen
Yu-Feng Chen
To determine the minimum thickness required for a monolithic hybrid ceramic crown on different substrates (soft vs stiff) used in posterior dentition for bruxism. 80 polymer-infiltrated ceramic networks Vita Enamic (PICN VE) disc specimens with four different occlusal thicknesses (0.8, 1.2, 1.6 and 2.0 mm), were produced using a computer-aided design/manufacturing system, and cemented on a stiff (zirconia) or soft (polyamide) substrate of 4-mm thickness. The ten specimens, in soft or stiff groups, were subjected to compressive loading by a MTS machine until fracture or maximum load (4500 N) was reached. The unbroken specimens were examined using optical coherence tomography. Eight axisymmetric finite element models and eight 3D models comprising the four different occlusal thicknesses and two substrates under different vertical loads and sliding movements were constructed. The maximum principal stress was selected to evaluate the stress distribution in this study. The fracture resistance of the specimens was significantly different between the two substrates (P < 0.001). Fracture resistance was positively associated with specimen thickness (r = 0.597 and 0.896 for the soft and stiff substrate respectively). Specimens on the soft substrate had lower fracture loads, whilst cone cracks were observed in unbroken samples on different soft/stiff substrate prior to final fracture. The finite element analysis confirmed that samples on the stiff substrate had lower maximum principal stress values than those on the soft substrate. For the maximum principal stress not to exceed the flexural strength of PICN VE, a stiff substrate and minimum thickness of 2.0 mm are required for the prostheses. A minimum 2.0 mm thick, stiff substrate was needed for bruxism as shown by the effect of high/large chewing force on the posterior dentition of monolithic PICN VE crowns.

25 May 2023 in New England Journal of Medicine
Verified
Journal Article
Closed access
YCYu-Feng Chen
Yu-Feng Chen
HCHong-Po Chang
Hong-Po Chang

28 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YCYu-Feng Chen
Yu-Feng Chen
CPChin-Yun Pan
Chin-Yun Pan
YCYung-Chung Chen
Yung-Chung Chen
JDJE-KANG Du
JE-KANG Du
TLTing-Hsun Lan
Ting-Hsun Lan
This in vitro study investigated the accuracy and wear conditions of three drill sleeve distances (0.01, 0.02, and 0.03 mm) for 3D-guided stents in simulated clinical dental implant surgery. Fifteen sets of upper and lower partially edentulous epoxy tooling board models with four edentulous first molar sites were prepared in a Nissin Simple Manikin II and set on a dental chair. Sixty computer-aided design and computer-aided manufacturing (CAD/CAM) designed and guided stents with three drill sleeve distances were prepared in this study. The maximum height (Sz) of the wear roughness of drills, maximum deviation, and drilling time were observed. The highest maximum horizontal deviations were observed at the upper first molar (0.48 ± 0.12 mm, p < 0.001). The highest maximum vertical and angular deviations were observed at the lower left first molar (1.08 ± 0.35 mm and 5.61° ± 1.21°, respectively, p < 0.001). Only angular deviation significantly differed among the three drill sleeve distances (p = 0.046); the 0.03 mm distance exhibited the maximum angular deviation (3.92° ± 1.87°). The bigger drill sleeve distance (0.03 mm) was associated with more wear roughness (8.70 ± 2.29 µm) of the drills. Guided stents with varying drill-sleeve distances (0.01, 0.02, and 0.03 mm) exhibited no significant difference in preparation drilling time and abrasive wear. In practice, the optimal drill sleeve distance for single-type CAD/CAM-guided stents of dental implantation was 0.01 mm.

29 June 2021 in Journal of Dental Sciences
Verified
Journal Article
Open access
YCYu-Feng Chen
Yu-Feng Chen
MSMing-Hsuan Sheen
Ming-Hsuan Sheen
HCHong-Po Chang
Hong-Po Chang
YTYu-Chuan Tseng
Yu-Chuan Tseng

8 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
TLTing-Hsun Lan
Ting-Hsun Lan
YCYu-Feng Chen
Yu-Feng Chen
YWYen-Yun Wang
Yen-Yun Wang
Mitch ChouMitch Chou
Mitch Chou
The computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication technique has become one of the hottest topics in the dental field. This technology can be applied to fixed partial dentures, removable dentures, and implant prostheses. This study aimed to evaluate the feasibility of NaCaPO4-blended zirconia as a new CAD/CAM material. Eleven different proportional samples of zirconia and NaCaPO4 (xZyN) were prepared and characterized by X-ray diffractometry (XRD) and Vickers microhardness, and the milling property of these new samples was tested via a digital optical microscope. After calcination at 950 °C for 4 h, XRD results showed that the intensity of tetragonal ZrO2 gradually decreased with an increase in the content of NaCaPO4. Furthermore, with the increase in NaCaPO4 content, the sintering became more obvious, which improved the densification of the sintered body and reduced its porosity. Specimens went through milling by a computer numerical control (CNC) machine, and the marginal integrity revealed that being sintered at 1350 °C was better than being sintered at 950 °C. Moreover, 7Z3N showed better marginal fit than that of 6Z4N among thirty-six samples when sintered at 1350 °C (p < 0.05). The milling test results revealed that 7Z3N could be a new CAD/CAM material for dental restoration use in the future.