Ye Li

Dr. Ye Li


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2020 in Neurological Sciences
Verified
Journal Article
Closed access
PDF file
JZJianYuan Zhang
JianYuan Zhang
BZBin Zhang
Bin Zhang
QRQingGuo Ren
QingGuo Ren
QZQing Zhong
Qing Zhong
YLYe Li
Ye Li
CZCuiping Zhao
Cuiping Zhao

18 June 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
YLYe Li
Ye Li
AGAkilesh Gokul
Akilesh Gokul
CMCharles McGhee
Charles McGhee
MZMohammed Ziaei
Mohammed Ziaei
Purpose: To investigate the repeatability in corneal thickness (CT) and epithelial thickness (ET) measurements using spectral domain anterior segment optical coherence tomography (AS-OCT, REVO NX, Optopol) in keratoconus, and examine the effect of corneal crosslinking (CXL) on repeatability. Methods: A cross-sectional study of 259 eyes of 212 patients with keratoconus attending the corneal disease clinic at a university hospital tertiary referral center were enrolled. Two groups were analysed: eyes with no prior history of CXL (Group A) and eyes with prior CXL (Group B). Repeatability of measurements was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV). Results: In Group A, central corneal thickness (CCT) was 472.18 ± 45.41μm, and the ET was found to be the thinnest in the inferior-temporal aspect at 51.79 ± 5.97μm and thickest at the superior-nasal aspect at 56.07 ± 5.70μm. In Group B, CCT was 465.11± 42.28μm, and the ET was the thinnest at the inferior-temporal aspect at 50.63 ± 5.52μm and thickest at the superior aspect at 56.80 ± 6.39μm. When evaluating CT measurements, ICC was above 0.86 and 0.83 for Group A and Group B respectively. When evaluating ET measurements, ICC was above 0.82 for both groups. CXL had no statistically significant impact on the repeatability of measurements. Conclusions: AS-OCT provides repeatable CT and ET measurements in the central and peripheral cornea in patients with keratoconus. Repeatability is not affected by a history of CXL.

22 December 2021 in Cornea
Verified
Journal Article
Closed access
SNSoobin MBChB Namkung
Soobin MBChB Namkung
ABAlexander Buckenham MBChB Boyle
Alexander Buckenham MBChB Boyle
YLYe Li
Ye Li
AGAkilesh Boptom (Hons) Gokul
Akilesh Boptom (Hons) Gokul
CMCharles DSc McGhee
Charles DSc McGhee
MZMohammed Md Ziaei
Mohammed Md Ziaei
Purpose: The purpose of this study was to assess the repeatability and agreement of horizontal white-to-white (WTW) measurements using 4 different imaging modalities including a slit-scanning elevation topographer, dual rotating Scheimpflug camera and Placido Disc tomographer, Placido Disc topographer, and anterior segment optical coherence (OCT) tomographer. Methods: In this prospective study, 33 eyes of 33 healthy subjects were scanned 3 times using each of the Orbscan IIz, Sirius, Nidek OPD III, and DRI OCT Triton devices and WTW measurements were recorded. Repeatability was assessed using the intraclass correlation coefficient (ICC), and agreement was analyzed using Bland–Altman plots. Results: Mean WTW values obtained from the Orbscan IIz, Sirius, Nidek, and DRI OCT Triton devices were 11.76 ± 0.41, 12.10 ± 0.45, 12.14 ± 0.41, and 12.40 ± 0.48 mm, respectively. Overall, there was high repeatability, with the ICC >0.86 for all devices. The Sirius showed the highest repeatability (ICC = 0.993), and the Nidek the lowest (ICC = 0.870). All pairwise comparison showed significant differences in the mean WTW measurements (P < 0.01) except between Sirius and Nidek (P = 0.27). Mean differences showed that the DRI OCT Triton had the highest WTW values, followed by Nidek, Sirius, and finally by Orbscan, which provided the lowest measurements. All pairwise comparisons had wide limits of agreements (between 0.60 and 0.80 mm). Conclusions: In healthy subjects the 4 devices demonstrated high repeatability in WTW measurement. However, a poor agreement between the devices suggests that they should not be used interchangeably for WTW measurements in clinical practice.

21 May 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
YLYe Li
Ye Li
AGAkilesh Gokul
Akilesh Gokul
CMCharles McGhee
Charles McGhee
MZMohammed Ziaei
Mohammed Ziaei
Purpose: To compare the repeatability and agreement in biometric measurements using Spectral Domain Anterior Segment OCT (AS-OCT, REVO-NX, Optopol) and Scheimpflug tomography (Pentacam-AXL, Oculus) in keratoconus. Methods: Prospective case series at a university hospital tertiary center. Axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), and thinnest corneal thickness (TCT) were measured using both devices in patients with keratoconus. Three groups were analyzed: eyes with no prior crosslinking or contact lens wear (Group A), eyes with prior crosslinking (Group B), and eyes with prior contact lens wear (Group C). Repeatability and agreement of measurements were analyzed. Results: The study comprised of 214 eyes of 157 subjects. In Group A (n = 95 eyes), Group B (n = 86 eyes), and Group C (n = 33 eyes), intraclass correlation coefficient (ICC) was higher than 0.90 for all examined parameters, except for ACD readings in Group A with the REVO-NX (ICC = 0.83). Differences in ACD, TCT, and CCT were significantly different between the two devices for Groups A, B and C (p<0.05). AL measurements differed significantly in Groups A and B (p0.05). There was poor agreement between the two devices across all parameters (p<0.05). Conclusions: Both devices demonstrated good repeatability but poor agreement across AL, ACD, CCT and TCT measurements. There was no significant difference in repeatability in virgin eyes compared to eyes with prior crosslinking or contact lens wear, however, the interchangeable use of the two devices is not recommended.

19 April 2023 in Eye
Verified
Journal Article
Closed access
PDF file
HWHimanshu Wadhwa
Himanshu Wadhwa
AGAkilesh Gokul
Akilesh Gokul
YLYe Li
Ye Li
ICIsabella Cheung
Isabella Cheung
LALize Angelo
Lize Angelo
MZMohammed Ziaei
Mohammed Ziaei

16 October 2020 in Cornea
Verified
Journal Article
Closed access
HNHamed Niyazmand
Hamed Niyazmand
JMJames McKelvie
James McKelvie
YLYe Li
Ye Li
CMCameron FRANZCO McLintock
Cameron FRANZCO McLintock
Purpose: To compare the visual and tomographic outcomes of epithelium-on and epithelium-off corneal collagen crosslinking (CXL) in an accelerated protocol in eyes with progressive keratoconus. Methods: Sixty-one patients with progressive keratoconus (female patients, n = 30; male patients, n = 31) aged 17 and 48 years (mean age: 25.8 ± 6.2 yrs) were included in this study. Patients underwent either epithelium-off (n = 27) or epithelium-on (n = 34) CXL using an accelerated protocol. Patients with at least 12 months of follow-up were included in the study. Visual and tomographic data from 3, 6, and 12 months after surgery were analyzed. Results: There were no differences between the visual and tomographic characteristics of the epithelium-on and epithelium-off groups at baseline (P > 0.05). No significant changes in uncorrected and best spectacles-corrected visual acuity were found at any stage during the first 12 months within either group or between the groups (all P > 0.05). There were no changes in thickness and keratometric parameters at any stage during the first 12 months within either group, or between groups (P > 0.05) except for a transient significant thinning of the central cornea in all groups in the first 3 months which recovered by 6 months. There was no significant difference between groups regarding the number of eyes with progression in the 12 months after treatment (P > 0.05). Conclusions: Epithelium-on and epithelium-off CXL in an accelerated protocol provide comparable visual and tomographic outcomes after 1 year in eyes with progressive keratoconus.