VP Nguyen

Dr. VP Nguyen

Computer Science and Engineering, The University of Texas at Arlington, Arlington, TX 12329, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2021 in IEEE Transactions on Mobile Computing
Verified
Journal Article
Closed access
NPNhat Pham
Nhat Pham
TDTuan Dinh
Tuan Dinh
TKTaeho Kim
Taeho Kim
ZRZohreh Raghebi
Zohreh Raghebi
NBNam Bui
Nam Bui
VNVP Nguyen
VP Nguyen
Every year, the U.S. economy loses more than $411 billion because of work performance reduction, injuries, and traffic accidents caused by microsleep. To mitigate microsleeps consequences, an unobtrusive, reliable, and socially acceptable microsleep detection solution throughout the day, every day is required. Unfortunately, existing solutions do not meet these requirements. In this paper, we propose WAKE, a novel behind-the-ear wearable device for microsleep detection. By monitoring biosignals from the brain, eye movements, facial muscle contractions, and sweat gland activities from behind the user's ears, WAKE can detect microsleep with a high temporal resolution. We introduce a Three-fold Cascaded Amplifying (3CA) technique to tame the motion artifacts and environmental noises for capturing high fidelity signals. Through our prototyping, we show that WAKE can suppress motion and environmental noise in real-time by 9.74-19.47 dB while walking, driving, or staying in different environments ensuring that the biosignals are captured reliably. We evaluated WAKE using gold-standard devices on 19 sleep-deprived and narcoleptic subjects. The Leave-One-Subject-Out Cross-Validation results show the feasibility of WAKE in microsleep detection on an unseen subject with average precision and recall of 76% and 85%, respectively.

16 July 2023 in Cancers
Verified
Journal Article
Open access
PDF file
HRHarish Ramachandramoorthy
Harish Ramachandramoorthy
TDTuan Dang
Tuan Dang
ASAnkitha Srinivasa
Ankitha Srinivasa
Kytai T. NguyenKytai T. Nguyen
Kytai T. Nguyen
VNVP Nguyen
VP Nguyen
Clinical resistance towards treatment is a major concern in cancer therapy. This is due to in vitro studies lacking essential microenvironmental aspects. Tumor-hypoxia is an important pathophysiological phenomenon in numerous malignant tumors. Various studies have shown the importance of a hypoxic microenvironment (HME) in cancer drug resistance and its effects on cellular signaling and metabolism pathways. Most drugs fail in transition from a laboratory to clinical trials because of the variability in the testing microenvironment conditions. It is, thus, very crucial that research work needs to replicate these conditions in vitro to test the drugs and/or drug carriers for cancer therapy. Previous works have used a portable hypoxia chamber to reduce the cell microenvironment to hypoxic conditions. These techniques lack reliability and consistency due to a lack of control and visualization. In this research, we developed a smart portable hypoxia chamber that could accurately control the oxygen inside the portable chamber and have a global visualization. The proposed hypoxia chamber provided ease of use with the ranges of 1% to 20% oxygen with increments of 0.5%, as well as reproducibility and accuracy. The chamber displayed great precision on reaching the set oxygen limit and a high stability in maintaining that set level of oxygen compared to the uncontrolled setup for extended durations (24 h). For instance, at a 2% oxygen level, our automated system maintained this level over 1400 min, whereas the oxygen level fluctuated up to 4.5% in the conventional hypoxic chamber. We have also demonstrated the pitfalls of uncontrolled and non-visualized hypoxia chamber setup and the dire need for our system. The hypoxia-induced factor (HIF-1α) expression in cancer cell lines was tested and compared between the conventional hypoxia setup and our automated hypoxia chamber. We observed that there was a twofold increase in HIF-1α expression in the automated controlled chamber compared to the conventional device. The device also provided real-time sensing, visualization and control of the chamber conditions, which could aid in complex in vitro studies.