Obtaining the in-depth information of radioactive contaminants is crucial for determining the most cost-effective decommissioning strategy. The main limitations of a burial depth analysis lie in the assumptions that foreknowledge of buried radioisotopes present at the site is always available and that only a single radioisotope is present. We present an advanced depth estimation method using Bayesian inference, which does not rely on those assumptions. Thus, we identified low-level radioactive contaminants buried in a substance and then estimated their depths and activities. To evaluate the performance of the proposed method, several spectra were obtained using a 3 × 3 inch hand-held NaI (Tl) detector exposed to Cs-137, Co-60, Na-22, Am-241, Eu-152, and Eu-154 sources (less than 1μCi) that were buried in a sandbox at depths of up to 15 cm. The experimental results showed that this method is capable of correctly detecting not only a single but also multiple radioisotopes that are buried in sand. Furthermore, it can provide a good approximation of the burial depth and activity of the identified sources in terms of the mean and 95% credible interval in a single measurement. Lastly, we demonstrate that the proposed technique is rarely susceptible to short acquisition time and gain-shift effects.
There has been considerable interest in inorganic scintillators based on lutetium due to their favorable physical properties. Despite their advantages, lutetium-based scintillators could face issues because of the natural occurring radioisotope of 176Lu that is contained in natural lutetium. In order to mitigate its potential shortcomings, previous works have studied to understand the energy spectrum of the intrinsic radiation of 176Lu (IRL). However, few studies have focused on the various principal types of photon interactions with matter; in other words, only the full-energy peak according to the photoelectric effect or internal conversion have been considered for understanding the energy spectrum of IRL. Thus, the approach we have used in this study considers other principal types of photon interactions by convoluting each energy spectrum with combinations for generating the spectrum of the intrinsic radiation of 176Lu. From the results, we confirm that the method provides good agreement with the experiment. A significant contribution of this study is the provision of a new approach to process energy spectra induced by mutually independent radiation interactions as a single spectrum.
Estimating accurate radiation doses when a radioactive source’s location is unknown can protect workers from radiation exposure. Unfortunately, depending on a detector’s shape and directional response variations, conventional G(E) function can be prone to inaccurate dose estimations. Therefore, this study estimated accurate radiation doses regardless of source distributions, using the multiple G(E) function groups (i.e., pixel-grouping G(E) functions) within a position-sensitive detector (PSD), which records the response position and energy inside the detector. Investigations revealed that, compared with the conventional G(E) function when source distributions are unknown, this study’s proposed pixel-grouping G(E) functions improved dose estimation accuracy by more than 1.5 times. Furthermore, although the conventional G(E) function produced substantially larger errors in certain directions or energy ranges, the proposed pixel-grouping G(E) functions estimate doses with more uniform errors at all directions and energies. Therefore, the proposed method estimates the dose with high accuracy and provides reliable results regardless of the location and energy of the source.