Contaminated sediment can release hydrophobic organic contaminants (HOCs) and thereby act as a secondary source of primarily legacy hazardous substances to the water column. There is therefore a need for assessments of the release of HOCs from contaminated sediment for prioritization of management actions. In situ assessment of HOC sediment-to-water flux is currently done with (closed) benthic flux chambers, which have a sampling time exceeding one month. During this time, the water inside the chamber is depleted of oxygen and the effect of bioturbation on the sediment-to-water release of HOCs is largely ignored. Here we present a novel benthic flux chamber, which measures sediment-to-water flux of legacy HOCs within days, and includes the effect of bioturbation since ambient oxygen levels inside the chamber are maintained by continuous pumping of water through the chamber. This chamber design allows for sediment-to-water flux measurements under more natural conditions. The chamber design was tested in a contaminated Baltic Sea bay. Measured fluxes were 62-2300 ng m-2 d-1 for individual polycyclic aromatic hydrocarbons (PAHs), and 5.5-150 ng m-2 d-1 for polychlorinated biphenyls (PCBs). These fluxes were 3-23 times (PAHs) and 12-74 times (PCBs) higher than fluxes measured with closed benthic chambers deployed in parallel at the same location. We hypothesize that the observed difference in HOC flux between the two chamber designs are partly an effect of bioturbation. This hypothesized effect of bioturbation was in accordance with literature data from experimental studies.
Carbon capture and storage (CCS) could significantly contribute to reducing greenhouse gas emissions and reaching international climate goals. In this process, CO2 is captured and injected into geological formations for permanent storage. The injected plume and its migration within the reservoir is carefully monitored, using geophysical methods. While it is considered unlikely that the injected CO2 should escape the reservoir and reach the marine environment, marine monitoring is required to verify that there are no indications of leakage, and to detect and quantify leakage if it should occur. Marine monitoring is challenging because of the considerable area to be covered, the limited spatial and temporal extent of a potential leakage event, and the considerable natural variability in the marine environment. In this review, we summarize marine monitoring strategies developed to ensure adequate monitoring of the marine environment without introducing prohibitive costs. We also provide an overview of the many different technologies applicable to different aspects of marine monitoring of geologically stored carbon. Finally, we identify remaining knowledge gaps and indicate expected directions for future research.
18 September 2015 in Environmental Science & Technology Letters
Here we demonstrate a distributed fibre optic sensor for the detection of liquid hydrocarbons. Two commercially available low-density ethylene-octene polyolefin elastomers with different properties are used to coat fibre optic cables, where the swelling of the coating upon absorption of hydrocarbons imparts strain on the fibre. By frequency domain analysis of the backscatter, the location of oil on the fibre is determined with high precision. The elastomer with the highest flexural modulus, hardness and tensile strength (Engage 8150) imposes more than three times more strain on the fibre compared to the softer elastomer (Engage 8180), despite the Engage 8180 expanding more than three times more in volume compared to the Engage 8150. A response occurs within a few seconds following oil interaction, and a maximum response of 700 microstrain (μɛ) is achieved with a response time of 1.5 minutes (t63) when a dry fibre is exposed to oil, whereas a maximum response of 400 μɛ is achieved when the fibre is exposed to oil when submerged in water. The results demonstrate that optical fibres coated in this way are able to detect and locate small quantities of oil with high degree of spatial resolution. The technique could be scaled to fibre covering long distances, and makes the sensor interesting for pipeline leak detection both on -and offshore, as well as for oil production monitoring purposes downhole.
28 November 2024 in Environmental Science & Technology
Here, we present a novel micro Total Analysis System (mu TAS) for the measurement of poly cyclic aromatic hydrocarbon (PAH) and other aromatic hydrocarbons (AHs) in water at ng/L levels in situ and in real time (IMiRO). The mu TAS is based on in-line membrane extraction followed by detection of extracted aromatic substances with fluorescence. An offshore field demonstration of the method was conducted close to produced water (PW) discharged in the North Sea. PW was monitored with the IMiRO mu TAS and compared to results from a simultaneously conducted independent tracer release experiment, where fluorescein was added to the PW as a tracer. The mu TAS monitoring and fluorescein tracer experiment showed similar ability to track the dispersion of the PW plume in space, depth, and time. Moreover, the method detected the sum of phenanthrenes and the sum of heavier PAHs with limits of detection down to 6 ng/L, with a response time of 6 min. The novel mu TAS system opens up for in situ real-time discharge monitoring of both permitted and accidental oil or PW releases from oil platforms as well as other sources. Such monitoring can also be used to test and verify dispersion models used for environmental risk assessment.
Remediation activities in polluted sediments, such as dredging and capping, induce the risk of transporting polluted sediments into the water column. Turbidity surveillance is the common method for in situ environmental monitoring during such activities. However, at various stages of the remediation process, the turbidity may be caused by either clean or polluted materials. Here, the potential of using chemical sensors to discriminate between turbidity caused by clean and polluted sediments is evaluated. Dissolved oxygen (DO), turbidity and pH were measured in laboratory tests with suspensions of three different polluted sediments, as well as for two common clean capping materials. Additionally, turbidity, pH and DO were measured during dredging at one of the polluted sites. While turbidity caused by clean materials did not affect pH or DO, there was an inverse linear relationship between DO and turbidity for two of the polluted sediments. Furthermore, for two of the sediments, pH was a strong indicator of sediment resuspension into the water column, with ΔpH > 0.5 both in the lab and during dredging in the field. Hence, pH and/or DO surveillance showed to be a potential tool for in situ real-time monitoring of environmental risk during disturbances in polluted sediments.