Fat in human milk is extremely variable and can represent up to 50 % of infant energy intake. To accurately determine milk composition and infant intake at 1 (n 17), 2 (n 17), 4 (n 17), 6 (n 15), 9 (n 6) and 12 (n 5) months of lactation, samples of fore- and hind-milk were collected from each breast at each feed over 24 h periods from an initial group of seventeen women. The content of fat in milk varied over 24 h, with a mean CV of 47·6 (SE 2·1) % (N 76) AND 46·7 (se 1·7) % (n 76) for left and right breasts respectively. The 24 h amounts of fat, lactose and protein in milk differed between women (P=0·0001), but were consistent between left and right breasts. Daily milk production differed between breasts (P=0·0001) and women (P=0·0001). Accordingly, amounts of fat (P=0·0008), lactose (P=0·0385) and protein (P=0·0173) delivered to the infant over 24 h also differed between breasts and women (P=0·0001). The energy content of milk and the amount of energy delivered to the infant over 24 h were the same between breasts, but differed between women (P=0·0001). The growth rate of a group of only six infants in the present study was not related to either the concentrations or amounts of fat, lactose, protein and energy in milk over the first 6 months of life. These results show the individuality of milk composition and suggest that only a rigorous sampling routine that takes into account all levels of variation will allow the accurate determination of infant intake of fat, lactose, protein and energy.
Researchers have recently called for human lactation research to be conceptualized as a biological framework where maternal and infant factors impacting human milk, in terms of composition, volume and energy content are studied along with relationships to infant growth, development and health. This approach allows for the development of evidence-based interventions that are more likely to support breastfeeding and lactation in pursuit of global breastfeeding goals. Here we summarize the seminal findings of our research programme using a biological systems approach traversing breast anatomy, milk secretion, physiology of milk removal with respect to breastfeeding and expression, milk composition and infant intake, and infant gastric emptying, culminating in the exploration of relationships with infant growth, development of body composition, and health. This approach has allowed the translation of the findings with respect to education, and clinical practice. It also sets a foundation for improved study design for future investigations in human lactation.
Despite the importance of human milk fatty acids for infant growth and development, there are few reports describing infant intakes of individual fatty acids. We have measured volume, fat content and fatty acid composition of milk from each breast at each feed over a 24h period to determine the mean daily amounts of each fatty acid delivered to the infant from breast milk at 1, 2, 4, 6, 9 and 12 months of lactation in five women. Daily (24h) milk production was 336·60 (sem 26·21) and 414·49 (sem 28·39) ml and milk fat content was 36·06 (sem 1·37) and 34·97 (sem 1·50) g/l for left and right breasts respectively over the course of the first year of lactation. Fatty acid composition varied over the course of the day (mean CV 14·3 (sd 7·7) %), but did not follow a circadian rhythm. The proportions (g/100g total fatty acids) of fatty acids differed significantly between mothers (P<0·05) and over the first year of lactation (P<0·05). However, amounts (g) of most fatty acids delivered to the infant over 24h did not differ during the first year of lactation and only the amounts of 18:3n-3, 22:5n-3 and 22:6n-3 delivered differed between mothers (P<0·05). Mean amounts of 18:2n-6, 18:3n-3, 20:4n-6 and 22:6n-3 delivered to the infant per 24h over the first year of lactation were 2·380 (sd 0·980), 0·194 (sd 0·074), 0·093 (sd 0·031) and 0·049 (sd 0·021) g respectively. These results suggest that variation in proportions of fatty acids may not translate to variation in the amount delivered and that milk production and fat content need to be considered.
Mastitis is a debilitating condition that can impact around 20% of mothers and is characterized by fever, flu-like symptoms and tender, swollen areas of the breasts. Despite the emerging evidence that breast milk dysbiosis is an underlying cause of mastitis, breast pumps have been implicated as a predisposing risk factor in the pathophysiology of mastitis in breastfeeding mothers. Previous studies have suggested that the use of a breast pump increases a mother's risk for developing mastitis, however, incidence rates of mastitis over the stages of lactation do not match breast pump usage rates. Furthermore, breast pumps, even when used at low vacuum, still promote some breast drainage, thus avoiding milk stasis, which is considered a key factor in the development of mastitis. As a consequence, these data suggest that the literature association of breast pumps with mastitis is more a case of reverse causation and not direct association. Moreover, it is important to note that breast pumps are actually a part of the conservative management of mastitis. In combination, these data show that the breast pump should not be considered a driver in the pathophysiology of mastitis in women.