To evaluate the feasibility of diffusion-tensor (DT) imaging at 3 T for functional assessment of transplanted kidneys. This study was approved by the local ethics committee; written informed consent was obtained. Between August 2009 and October 2010, 40 renal transplant recipients were prospectively included in this study and examined with a clinical 3-T magnetic resonance (MR) imager. An echo-planar DT imaging sequence was performed in coronal orientation by using five b values (0, 200, 400, 600, 800 sec/mm(2)) and 20 diffusion directions. The fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were determined for the cortex and medulla of the transplanted kidney. Relationships between FA, ADC, and allograft function, determined by the estimated glomerular filtration rate (eGFR), were assessed by using Pearson correlation coefficient. ADC and FA were compared between patients with good or moderate allograft function (group A; eGFR > 30 mL/min/1.73 m(2)) and patients with impaired function (group B; eGFR ≤ 30 mL/min/1.73 m(2)) by using a student t test. P < .05 indicated a statistically significant difference. Mean FA of the renal medulla and cortex was significantly higher in group A (0.39 ± 0.06 and 0.17 ± 0.4) compared with group B (0.27 ± 0.05 and 0.14 ± 0.03) (P < .001 and P = .009, respectively). Mean ADCs of renal cortex and medulla were significantly higher in group A than in group B (P = .007 and P = .01, respectively). In group B, mean medullary FA was significantly lower in patients whose renal function did not recover (0.22 ± 0.02) compared with those with stable allograft function at 6 months (0.29 ± 0.05, P < .001). There was significant correlation between eGFR and medullary FA (r = 0.65, P < .001), cortical ADC (r = 0.43, P = .003), and medullary ADC (r = 0.35, P = .01). DT imaging is a promising noninvasive technique for functional assessment of renal allografts. FA values in the renal medulla exhibit a good correlation with renal function.
1 November 2019 in Magnetic Resonance Materials in Physics, Biology and Medicine
Objectives: Standardization is an important milestone in the validation of DWI-based parameters as imaging biomarkers for renal disease. Here, we propose technical recommendations on three variants of renal DWI, monoexponential DWI, IVIM and DTI, as well as associated MRI biomarkers (ADC, D, D*, f, FA and MD) to aid ongoing international efforts on methodological harmonization. Materials and methods: Reported DWI biomarkers from 194 prior renal DWI studies were extracted and Pearson correlations between diffusion biomarkers and protocol parameters were computed. Based on the literature review, surveys were designed for the consensus building. Survey data were collected via Delphi consensus process on renal DWI preparation, acquisition, analysis, and reporting. Consensus was defined as ≥ 75% agreement. Results: Correlations were observed between reported diffusion biomarkers and protocol parameters. Out of 87 survey questions, 57 achieved consensus resolution, while many of the remaining questions were resolved by preference (65–74% agreement). Summary of the literature and survey data as well as recommendations for the preparation, acquisition, processing and reporting of renal DWI were provided. Discussion: The consensus-based technical recommendations for renal DWI aim to facilitate inter-site harmonization and increase clinical impact of the technique on a larger scale by setting a framework for acquisition protocols for future renal DWI studies. We anticipate an iterative process with continuous updating of the recommendations according to progress in the field.
7 October 2013 in Journal of Magnetic Resonance Imaging
Purpose: To assess the feasibility of measuring tubular and vascular signal fractions in the human kidney using nonnegative least‐square (NNLS) analysis of intravoxel incoherent motion data collected in healthy volunteers and patients with renal pathologies.Methods: MR imaging was performed at 3 Tesla in 12 healthy subjects and 3 patients with various kidney pathologies (fibrotic kidney disease, failed renal graft, and renal masses). Relative signal fractions f and mean diffusivities of the diffusion components in the cortex, medulla, and renal lesions were obtained using the regularized NNLS fitting of the intravoxel incoherent motion data. Test–retest repeatability of the NNLS approach was tested in 5 volunteers scanned twice.Results: In the healthy kidneys, the NNLS method yielded diffusion spectra with 3 distinguishable components that may be linked to the slow tissue water diffusion, intermediate tubular and vascular flow, and fast blood flow in larger vessels with the relative signal fractions, fslow, finterm and ffast, respectively. In the pathological kidneys, the diffusion spectra varied substantially from those acquired in the healthy kidneys. Overall, the renal cyst showed substantially higher finterm and lower fslow, whereas the fibrotic kidney, failed renal graft, and renal cell carcinoma demonstrated the opposite trend.Conclusion: NNLS‐based intravoxel incoherent motion could potentially become a valuable tool in assessing changes in tubular and vascular volume fractions under pathophysiological conditions.