This article presents a field-emission electron gun intended for use in a MEMS (microelectromechanical system) electron microscope. Its fabrication process follows the technology of a miniature device under development built from silicon electrodes and glass spacers. The electron gun contains a silicon cathode with a single very sharp protrusion and a bundle of disordered CNTs deposited on its end (called a sharp silicon/CNT cathode). It was tested in diode and triode configurations. For the diode configuration, a low threshold voltage <1000 V and a high emission current that reached 90 µA were obtained. After 30 min of operation at 900 V, the emission current decreased to 1.6 µA and was stable for at least 40 min, with RMS fluctuation in the anode current lower than 10%. The electron beam spot of the source was observed on the phosphor screen. In the diode configuration, the spot size was the same as the emission area (~10 µm), which is a satisfactory result. In the triode configuration, an extraction electrode (gate) control function was reported. The gate limited the emission current and elongated the lifetime of the gun when the current limit was set. Moreover, the electron beam current fluctuations at the anode could be reduced to ~1% by using a feedback loop circuit that controls the gate voltage, regulating the anode current. The developed sharp silicon/CNT cathodes were used to test the MEMS electron source demonstrator, a key component of the MEMS electron microscope, operating under atmospheric pressure conditions. Cathodoluminescence of the phosphor layer (ZnS:Ag) deposited on the thin silicon nitride membrane (anode) was observed.
A concept of a miniaturized microelectromechanical system based transmission electron microscope is presented. This device consists of two parts: part 1—electron optics column with a high vacuum micropump and part 2—sample chamber with a detector. These two parts are separated with a common electrode, called the anode. The anode consists of a very thin membrane (membrane-anode) that encloses the electron optics microsystem. It is used to let the electron beam pass to the sample and it must endure the pressure difference between its both parts. In this paper, the authors describe the fabrication process of the membrane-anode. It is made of Si3N4 layer deposited on an oxidized silicon substrate and is fabricated in five steps: photolithography, plasma etching, wet anisotropic etching, oxide stripping, and removing the Si3N4 and SiO2 layers. The membranes were characterized, and their preliminary performance parameters are presented, i.e., the endurance and the electron transmission.
The article presents the results of a new method for electron detection at atmospheric pressure (APED). This method is developed for a MEMS (Micro-Electro-Mechanical System) electron microscope to obtain images of a sample placed on a silicon nitride membrane in air. The electron beam is transmitted through the membrane and, under specific conditions, can reach the detector despite the presence of air molecules. The experiments were carried out on a miniature electron optical microcolumn model consisting of an octupole deflector, an anode with a Si 3 N 4 membrane, and an electron collector. The anode, glass spacer, and electron collector formed a microchamber that was filled with air. Measurements were made using an electron beam from JEOL Scanning Electron Microscope (SEM). The first images obtained using the APED method and a quantitative description of the operation principle are presented.