Remei Calm

Prof. Remei Calm

Universidad de Girona, Spain

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2001 in Reliable Computing
Verified
Journal Article
Closed access
PDF file
EGErnest Gardeñes
Ernest Gardeñes
MSMiguel Á. Sainz
Miguel Á. Sainz
JLJorba Lambert
Jorba Lambert
RCRemei Calm
Remei Calm
RERosa Estela
Rosa Estela
ATAlbert Trepat
Albert Trepat

1 September 2012 in Journal of Diabetes Science and Technology
Verified
Journal Article
Open access
PDF file
PHPau Herrero
Pau Herrero
RCRemei Calm
Remei Calm
Josep VehiJosep Vehi
Josep Vehi
JAJoaquim Armengol
Joaquim Armengol
PGPantelis Georgiou
Pantelis Georgiou
CTChristofer Tomazou
Christofer Tomazou
The popularity of continuous subcutaneous insulin infusion (CSII), or insulin pump therapy, as a way to deliver insulin more physiologically and achieve better glycemic control in diabetes patients has increased. Despite the substantiated therapeutic advantages of using CSII, its use has also been associated with an increased risk of technical malfunctioning of the device, which leads to an increased risk of acute metabolic complications, such as diabetic ketoacidosis. Current insulin pumps already incorporate systems to detect some types of faults, such as obstructions in the infusion set, but are not able to detect other types of fault such as the disconnection or leakage of the infusion set. In this article, we propose utilizing a validated robust model-based fault detection technique, based on interval analysis, for detecting disconnections of the insulin infusion set. For this purpose, a previously validated metabolic model of glucose regulation in type 1 diabetes mellitus (T1DM) and a continuous glucose monitoring device were used. As a first step to assess the performance of the presented fault detection system, a Food and Drug Administration-accepted T1DM simulator was employed. Of the 100 in silico tests (10 scenarios on 10 subjects), only two false negatives and one false positive occurred. All faults were detected before plasma glucose concentration reached 300 mg/dl, with a mean plasma glucose detection value of 163 mg/dl and a mean detection time of 200 min. Interval model-based fault detection has been proven (in silico) to be an effective tool for detecting disconnection faults in sensor-augmented CSII systems. Proper quantification of the uncertainty associated with the employed model has been observed to be crucial for the good performance of the proposed approach.

1 January 2009 in Journal of Diabetes Science and Technology
Verified
Journal Article
Open access
PDF file
JBJorge Bondia
Jorge Bondia
EDEyal Dassau
Eyal Dassau
HZHoward Zisser
Howard Zisser
RCRemei Calm
Remei Calm
Josep VehiJosep Vehi
Josep Vehi
FDFrancis J. Doyle
Francis J. Doyle
Basal and bolus insulin determination in intensive insulin therapy for type 1 diabetes mellitus (T1DM) are currently considered independently of each other. A new strategy that coordinates basal and bolus insulin infusion to cope with postprandial glycemia in pump therapy is proposed. Superior performance of this new strategy is demonstrated through a formal analysis of attainable performances in an in silico study. The set inversion via interval analysis algorithm has been applied to obtain the feasible set of basal and bolus doses that, for a given meal, mathematically guarantee a postprandial response fulfilling the International Diabetes Federation (IDF) guidelines (i.e., no hypoglycemia and 2 h postprandial glucose below 140 mg/dl). Hypoglycemia has been defined as a glucose value below 70 mg/dl. A 5 h time horizon has been considered for a 70 kg in silico T1DM subject consuming meals in the range of 30 to 80 g of carbohydrates. The computed feasible sets demonstrate that current separated basal/bolus strategy dramatically limits the attainable performance. For a nominal basal of 0.8 IU/h leading to a basal glucose of approximately 100 mg/dl, IDF guidelines cannot be fulfilled for meals greater than 50 g of carbohydrates, independent of the bolus insulin computed. However, coordinating the basal and bolus insulin delivery can achieve this. A decrement of basal insulin during the postprandial period is required together with an increase in bolus insulin, in appropriate percentages, which is meal dependent. After 3 h, basal insulin can be restored to its nominal value. The new strategy meets IDF guidelines in a typical day, contrary to the standard basal/bolus strategy, yielding a mean 2 h postprandial glucose reduction of 36.4 mg/dl without late hypoglycemia. The application of interval analysis for the computation of feasible sets is demonstrated to be a powerful tool for the analysis of attainable performance in glucose control.

7 March 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
Josep VehiJosep Vehi
Josep Vehi
JIJordi Regincós Isern
Jordi Regincós Isern
AAAdria Parcerisas Albes
Adria Parcerisas Albes
RCRemei Calm
Remei Calm
Ivan ContrerasIvan Contreras
Ivan Contreras
Background: Technology has long been used to carry out self-management as well as to improve adherence to treatment in people with diabetes. However, most technology-based apps do not meet the basic requirements for engaging patients. Objective: This study aimed to evaluate the effect of use frequency of a diabetes management app on glycemic control. Methods: Overall, 2 analyses were performed. The first consisted of an examination of the reduction of blood glucose (BG) mean, using a randomly selected group of 211 users of the SocialDiabetes app (SDA). BG levels at baseline, month 3, and month 6 were calculated using the intercept of a regression model based on data from months 1, 4, and 7, respectively. In the second analysis, the impact of low and high BG risk was examined. A total of 2692 users logging SDA ≥5 days/month for ≥6 months were analyzed. The highest quartile regarding low blood glucose index (LBGI) and high blood glucose index (HBGI) at baseline (t1) was selected (n=74 for group A; n=440 for group B). Changes in HBGI and LBGI at month 6 (t2) were analyzed. Results: For analysis 1, baseline BG results for type 1 diabetes mellitus (T1DM) groups A and B were 213.61 (SD 31.57) mg/dL and 206.43 (SD 18.65) mg/dL, respectively, which decreased at month 6 to 175.15 (SD 37.88) mg/dL and 180.6 (SD 40.47) mg/dL, respectively. For type 2 diabetes mellitus (T2DM), baseline BG was 218.77 (SD 40.18) mg/dL and 232.55 (SD 46.78) mg/dL, respectively, which decreased at month 6 to 160.51 (SD 39.32) mg/dL and 173.14 (SD 52.81) mg/dL for groups A and B, respectively. This represents a reduction of estimated A1c (eA1c) of approximately 1.3% (P<.001) and 0.9% (P=.001) for T1DM groups A and B, respectively, and 2% (P<.001) for both A and B T2DM groups, respectively. For analysis 2, T1DM baseline LBGI values for groups A and B were 5.2 (SD 3.9) and 4.4 (SD 2.3), respectively, which decreased at t2 to 3.4 (SD 3.3) and 3.4 (SD 1.9), respectively; this was a reduction of 34.6% (P=.005) and 22.7% (P=.02), respectively. Baseline HBGI values for groups A and B were 12.6 (SD 4.3) and 10.6 (SD 4.03), respectively, which decreased at t2 to 9.0 (SD 6.5) and 8.6 (SD 4.7), respectively; this was a reduction of 30% (P=.001) and 22% (P=.003), respectively. Conclusions: A significant reduction in BG was found in all groups, independent of the use frequency of the app. Better outcomes were found for T2DM patients. A significant reduction in LBGI and HBGI was found in all groups, regardless of the use frequency of the app. LBGI and HBGI indices of both groups tend to have similar values after 6 months of app use.

1 December 2011 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
RCRemei Calm
Remei Calm
MJMaira Garcia Jaramillo
Maira Garcia Jaramillo
JBJorge Bondia
Jorge Bondia
MSM.A. Sainz
M.A. Sainz
Josep VehiJosep Vehi
Josep Vehi

1 January 2012 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
MJMaira Garcia Jaramillo
Maira Garcia Jaramillo
RCRemei Calm
Remei Calm
JBJorge Bondia
Jorge Bondia
CTC. Tarín
C. Tarín
Josep VehiJosep Vehi
Josep Vehi