Stefan Jaeger

Dr. Stefan Jaeger

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2013 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
SJStefan Jaeger
Stefan Jaeger
AKAlexandros Karargyris
Alexandros Karargyris
SCSema Candemir
Sema Candemir
LFLes Folio
Les Folio
JSJenifer Siegelman
Jenifer Siegelman
CMClement J. McDonald
Clement J. McDonald
Tuberculosis is a major health threat in many regions of the world. Opportunistic infections in immunocompromised HIV/AIDS patients and multi-drug-resistant bacterial strains have exacerbated the problem, while diagnosing tuberculosis still remains a challenge. When left undiagnosed and thus untreated, mortality rates of patients with tuberculosis are high. Standard diagnostics still rely on methods developed in the last century. They are slow and often unreliable. In an effort to reduce the burden of the disease, this paper presents our automated approach for detecting tuberculosis in conventional posteroanterior chest radiographs. We first extract the lung region using a graph cut segmentation method. For this lung region, we compute a set of texture and shape features, which enable the X-rays to be classified as normal or abnormal using a binary classifier. We measure the performance of our system on two datasets: a set collected by the tuberculosis control program of our local county's health department in the United States, and a set collected by Shenzhen Hospital, China. The proposed computer-aided diagnostic system for TB screening, which is ready for field deployment, achieves a performance that approaches the performance of human experts. We achieve an area under the ROC curve (AUC) of 87% (78.3% accuracy) for the first set, and an AUC of 90% (84% accuracy) for the second set. For the first set, we compare our system performance with the performance of radiologists. When trying not to miss any positive cases, radiologists achieve an accuracy of about 82% on this set, and their false positive rate is about half of our system's rate.

1 December 2014
Verified
Journal Article
Open access
SJStefan Jaeger
Stefan Jaeger
SCSema Candemir
Sema Candemir
SASameer Antani
Sameer Antani
YWYì-Xiáng J. Wáng
Yì-Xiáng J. Wáng
PLPu-Xuan Lu
Pu-Xuan Lu
GTGeorge Thoma
George Thoma
The U.S. National Library of Medicine has made two datasets of postero-anterior (PA) chest radiographs available to foster research in computer-aided diagnosis of pulmonary diseases with a special focus on pulmonary tuberculosis (TB). The radiographs were acquired from the Department of Health and Human Services, Montgomery County, Maryland, USA and Shenzhen No. 3 People’s Hospital in China. Both datasets contain normal and abnormal chest X-rays with manifestations of TB and include associated radiologist readings.

1 April 2018 in Translational Research
Verified
Journal Article
Open access
MPMahdieh Poostchi
Mahdieh Poostchi
KSKamolrat Silamut
Kamolrat Silamut
Richard MaudeRichard Maude
Richard Maude
SJStefan Jaeger
Stefan Jaeger
GTGeorge Thoma
George Thoma
Malaria remains a major burden on global health, with roughly 200 million cases worldwide and more than 400,000 deaths per year. Besides biomedical research and political efforts, modern information technology is playing a key role in many attempts at fighting the disease. One of the barriers toward a successful mortality reduction has been inadequate malaria diagnosis in particular. To improve diagnosis, image analysis software and machine learning methods have been used to quantify parasitemia in microscopic blood slides. This article gives an overview of these techniques and discusses the current developments in image analysis and machine learning for microscopic malaria diagnosis. We organize the different approaches published in the literature according to the techniques used for imaging, image preprocessing, parasite detection and cell segmentation, feature computation, and automatic cell classification. Readers will find the different techniques listed in tables, with the relevant articles cited next to them, for both thin and thick blood smear images. We also discussed the latest developments in sections devoted to deep learning and smartphone technology for future malaria diagnosis.

23 September 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
FYFeng Yang
Feng Yang
MPMahdieh Poostchi
Mahdieh Poostchi
HYHang Yu
Hang Yu
ZZZhou Zhou
Zhou Zhou
KSKamolrat Silamut
Kamolrat Silamut
Sameer AntaniSameer Antani
Sameer Antani
Objective: This work investigates the possibility of automated malaria parasite detection in thick blood smears with smartphones. Methods: We have developed the first deep learning method that can detect malaria parasites in thick blood smear images and can run on smartphones. Our method consists of two processing steps. First, we apply an intensity-based Iterative Global Minimum Screening (IGMS), which performs a fast screening of a thick smear image to find parasite candidates. Then, a customized Convolutional Neural Network (CNN) classifies each candidate as either parasite or background. Together with this paper, we make a dataset of 1819 thick smear images from 150 patients publicly available to the research community. We used this dataset to train and test our deep learning method, as described in this paper. Results: A patient-level five-fold cross-evaluation demonstrates the effectiveness of the customized CNN model in discriminating between positive (parasitic) and negative image patches in terms of the following performance indicators: accuracy (93.46% ± 0.32%), AUC (98.39% ± 0.18%), sensitivity (92.59% ± 1.27%), specificity (94.33% ± 1.25%), precision (94.25% ± 1.13%), and negative predictive value (92.74% ± 1.09%). High correlation coefficients (>0.98) between automatically detected parasites and ground truth, on both image level and patient level, demonstrate the practicality of our method. Conclusion: Promising results are obtained for parasite detection in thick blood smears for a smartphone application using deep learning methods. Significance: Automated parasite detection running on smartphones is a promising alternative to manual parasite counting for malaria diagnosis, especially in areas lacking experienced parasitologists.

27 February 2023 in IEEE Access
Verified
Journal Article
Open access
FYFeng Yang
Feng Yang
GZGhada Zamzmi
Ghada Zamzmi
SASandeep Angara
Sandeep Angara
Sivaramakrishnan RajaramanSivaramakrishnan Rajaraman
Sivaramakrishnan Rajaraman
AAAndré Aquilina
André Aquilina
Sameer AntaniSameer Antani
Sameer Antani
Artificial Intelligence (AI)-based medical computer vision algorithm training and evaluations depend on annotations and labeling. However, variability between expert annotators introduces noise in training data that can adversely impact the performance of AI algorithms. This study aims to assess, illustrate and interpret the inter-annotator agreement among multiple expert annotators when segmenting the same lesion(s)/abnormalities on medical images. We propose the use of three metrics for the qualitative and quantitative assessment of inter-annotator agreement: 1) use of a common agreement heatmap and a ranking agreement heatmap; 2) use of the extended Cohen’s kappa and Fleiss’ kappa coefficients for a quantitative evaluation and interpretation of inter-annotator reliability; and 3) use of the Simultaneous Truth and Performance Level Estimation (STAPLE) algorithm, as a parallel step, to generate ground truth for training AI models and compute Intersection over Union (IoU), sensitivity, and specificity to assess the inter-annotator reliability and variability. Experiments are performed on two datasets, namely cervical colposcopy images from 30 patients and chest X-ray images from 336 tuberculosis (TB) patients, to demonstrate the consistency of inter-annotator reliability assessment and the importance of combining different metrics to avoid bias assessment.

29 October 2020 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
YKYasmin Kassim
Yasmin Kassim
KPKannappan Palaniappan
Kannappan Palaniappan
FYFeng Yang
Feng Yang
MPMahdieh Poostchi
Mahdieh Poostchi
NPNila Palaniappan
Nila Palaniappan
SJStefan Jaeger
Stefan Jaeger
Computer-assisted algorithms have become a mainstay of biomedical applications to improve accuracy and reproducibility of repetitive tasks like manual segmentation and annotation. We propose a novel pipeline for red blood cell detection and counting in thin blood smear microscopy images, named RBCNet, using a dual deep learning architecture. RBCNet consists of a U-Net first stage for cell-cluster segmentation, followed by a second stage Faster R-CNN for detecting small cell objects within clusters, identified as connected components from the U-Net stage. RBCNet uses cell clustering instead of region proposals, which is robust to cell fragmentation, is highly scalable for detecting small objects or fine scale morphological structures in very large images, can be trained using non-overlapping tiles, and during inference is adaptive to the scale of cell-clusters with a low memory footprint. We tested our method on an archived collection of human malaria smears with nearly 200,000 labeled cells across 965 images from 193 patients, acquired in Bangladesh, with each patient contributing five images. Cell detection accuracy using RBCNet was higher than 97%. The novel dual cascade RBCNet architecture provides more accurate cell detections because the foreground cell-cluster masks from U-Net adaptively guide the detection stage, resulting in a notably higher true positive and lower false alarm rates, compared to traditional and other deep learning methods. The RBCNet pipeline implements a crucial step towards automated malaria diagnosis.