Josep Maria Font-Llagunes

Dr. Josep Maria Font-Llagunes

Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Center for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028 Barcelona, Spain
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
ARAntonio Rodríguez-Fernández
Antonio Rodríguez-Fernández
JLJoan Lobo-Prat
Joan Lobo-Prat
JFJosep Maria Font-Llagunes
Josep Maria Font-Llagunes
Gait disorders can reduce the quality of life for people with neuromuscular impairments. Therefore, walking recovery is one of the main priorities for counteracting sedentary lifestyle, reducing secondary health conditions and restoring legged mobility. At present, wearable powered lower-limb exoskeletons are emerging as a revolutionary technology for robotic gait rehabilitation. This systematic review provides a comprehensive overview on wearable lower-limb exoskeletons for people with neuromuscular impairments, addressing the following three questions: (1) what is the current technological status of wearable lower-limb exoskeletons for gait rehabilitation?, (2) what is the methodology used in the clinical validations of wearable lower-limb exoskeletons?, and (3) what are the benefits and current evidence on clinical efficacy of wearable lower-limb exoskeletons? We analyzed 87 clinical studies focusing on both device technology (e.g., actuators, sensors, structure) and clinical aspects (e.g., training protocol, outcome measures, patient impairments), and make available the database with all the compiled information. The results of the literature survey reveal that wearable exoskeletons have potential for a number of applications including early rehabilitation, promoting physical exercise, and carrying out daily living activities both at home and the community. Likewise, wearable exoskeletons may improve mobility and independence in non-ambulatory people, and may reduce secondary health conditions related to sedentariness, with all the advantages that this entails. However, the use of this technology is still limited by heavy and bulky devices, which require supervision and the use of walking aids. In addition, evidence supporting their benefits is still limited to short-intervention trials with few participants and diversity among their clinical protocols. Wearable lower-limb exoskeletons for gait rehabilitation are still in their early stages of development and randomized control trials are needed to demonstrate their clinical efficacy.

19 February 2023 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
JMJesús de Miguel-Fernández
Jesús de Miguel-Fernández
JLJoan Lobo-Prat
Joan Lobo-Prat
EPErik Prinsen
Erik Prinsen
JFJosep Maria Font-Llagunes
Josep Maria Font-Llagunes
LMLaura Marchal-Crespo
Laura Marchal-Crespo
Background: In the past decade, there has been substantial progress in the development of robotic controllers that specify how lower-limb exoskeletons should interact with brain-injured patients. However, it is still an open question which exoskeleton control strategies can more effectively stimulate motor function recovery. In this review, we aim to complement previous literature surveys on the topic of exoskeleton control for gait rehabilitation by: (1) providing an updated structured framework of current control strategies, (2) analyzing the methodology of clinical validations used in the robotic interventions, and (3) reporting the potential relation between control strategies and clinical outcomes.Methods: Four databases were searched using database-specific search terms from January 2000 to September 2020. We identified 1648 articles, of which 159 were included and evaluated in full-text. We included studies that clinically evaluated the effectiveness of the exoskeleton on impaired participants, and which clearly explained or referenced the implemented control strategy.Results: (1) We found that assistive control (100% of exoskeletons) that followed rule-based algorithms (72%) based on ground reaction force thresholds (63%) in conjunction with trajectory-tracking control (97%) were the most implemented control strategies. Only 14% of the exoskeletons implemented adaptive control strategies. (2) Regarding the clinical validations used in the robotic interventions, we found high variability on the experimental protocols and outcome metrics selected. (3) With high grade of evidence and a moderate number of participants (N = 19), assistive control strategies that implemented a combination of trajectory-tracking and compliant control showed the highest clinical effectiveness for acute stroke. However, they also required the longest training time. With high grade of evidence and low number of participants (N = 8), assistive control strategies that followed a threshold-based algorithm with EMG as gait detection metric and control signal provided the highest improvements with the lowest training intensities for subacute stroke. Finally, with high grade of evidence and a moderate number of participants (N = 19), assistive control strategies that implemented adaptive oscillator algorithms together with trajectory-tracking control resulted in the highest improvements with reduced training intensities for individuals with chronic stroke.Conclusions: Despite the efforts to develop novel and more effective controllers for exoskeleton-based gait neurorehabilitation, the current level of evidence on the effectiveness of the different control strategies on clinical outcomes is still low. There is a clear lack of standardization in the experimental protocols leading to high levels of heterogeneity. Standardized comparisons among control strategies analyzing the relation between control parameters and biomechanical metrics will fill this gap to better guide future technical developments. It is still an open question whether controllers that provide an on-line adaptation of the control parameters based on key biomechanical descriptors associated to the patients’ specific pathology outperform current control strategies.

26 June 2009 in Journal of Logic and Computation
Verified
Journal Article
Closed access
PDF file
FBFélix Bou
Félix Bou
FEFrancesc Esteva
Francesc Esteva
JFJosep Maria Font-Llagunes
Josep Maria Font-Llagunes
ÀGÀngel J. Gil
Àngel J. Gil
LGLluís Godo
Lluís Godo
VVVentura Verdú
Ventura Verdú
Let K be a variety of (commutative, integral) residuated lattices. The substructural logic usually associated with K is an algebraizable logic that has K as its equivalent algebraic semantics, and is a logic that preserves truth, i.e. 1 is the only truth value preserved by the inferences of the logic. In this article, we introduce another logic associated with K, namely the logic that preserves degrees of truth, in the sense that it preserves lower bounds of truth values in inferences. We study this second logic mainly from the point of view of abstract algebraic logic. We determine its algebraic models and we classify it in the Leibniz and the Frege hierarchies: we show that it is always fully selfextensional, that for most varieties K it is non-protoalgebraic, and that it is algebraizable if and only K is a variety of generalized Heyting algebras, in which case it coincides with the logic that preserves truth. We also characterize the new logic in three ways: by a Hilbert style axiomatic system, by a Gentzen style sequent calculus and by a set of conditions on its closure operator. Concerning the relation between the two logics, we prove that the truth-preserving logic is the extension of the one that preserves degrees of truth with either the rule of Modus Ponens or the rule of Adjunction for the fusion connective.

1 December 2012 in Mechanism and Machine Theory
Verified
Journal Article
Closed access
RPRosa Pàmies-Vilà
Rosa Pàmies-Vilà
JFJosep Maria Font-Llagunes
Josep Maria Font-Llagunes
Javier CuadradoJavier Cuadrado
Javier Cuadrado
FAFrancisco Javier Alonso-Sánchez
Francisco Javier Alonso-Sánchez

13 June 2016 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
GSGil Serrancolí
Gil Serrancolí
Allison Leigh KinneyAllison Leigh Kinney
Allison Leigh Kinney
Benjamin FreglyBenjamin Fregly
Benjamin Fregly
JFJosep Maria Font-Llagunes
Josep Maria Font-Llagunes
Though walking impairments are prevalent in society, clinical treatments are often ineffective at restoring lost function. For this reason, researchers have begun to explore the use of patient-specific computational walking models to develop more effective treatments. However, the accuracy with which models can predict internal body forces in muscles and across joints depends on how well relevant model parameter values can be calibrated for the patient. This study investigated how knowledge of internal knee contact forces affects calibration of neuromusculoskeletal model parameter values and subsequent prediction of internal knee contact and leg muscle forces during walking. Model calibration was performed using a novel two-level optimization procedure applied to six normal walking trials from the Fourth Grand Challenge Competition to Predict In Vivo Knee Loads. The outer-level optimization adjusted time-invariant model parameter values to minimize passive muscle forces, reserve actuator moments, and model parameter value changes with (Approach A) and without (Approach B) tracking of experimental knee contact forces. Using the current guess for model parameter values but no knee contact force information, the inner-level optimization predicted time-varying muscle activations that were close to experimental muscle synergy patterns and consistent with the experimental inverse dynamic loads (both approaches). For all the six gait trials, Approach A predicted knee contact forces with high accuracy for both compartments (average correlation coefficient r = 0.99 and root mean square error (RMSE) = 52.6 N medial; average r = 0.95 and RMSE = 56.6 N lateral). In contrast, Approach B overpredicted contact force magnitude for both compartments (average RMSE = 323 N medial and 348 N lateral) and poorly matched contact force shape for the lateral compartment (average r = 0.90 medial and −0.10 lateral). Approach B had statistically higher lateral muscle forces and lateral optimal muscle fiber lengths but lower medial, central, and lateral normalized muscle fiber lengths compared to Approach A. These findings suggest that poorly calibrated model parameter values may be a major factor limiting the ability of neuromusculoskeletal models to predict knee contact and leg muscle forces accurately for walking.

13 January 2020 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
JFJosep Maria Font-Llagunes
Josep Maria Font-Llagunes
ULUrbano Lugris
Urbano Lugris
DCDaniel Clos
Daniel Clos
FAFrancisco Javier Alonso-Sánchez
Francisco Javier Alonso-Sánchez
Javier CuadradoJavier Cuadrado
Javier Cuadrado
Walking rehabilitation using exoskeletons is of high importance to maximize independence and improve the general well-being of spinal cord injured subjects. We present the design and control of a lightweight and modular robotic exoskeleton to assist walking in spinal cord injured subjects who can control hip flexion, but lack control of knee and ankle muscles. The developed prototype consists of two robotic orthoses, which are powered by a motor-harmonic drive actuation system that controls knee flexion–extension. This actuation module is assembled on standard passive orthoses. Regarding the control, the stance-to-swing transition is detected using two inertial measurement units mounted on the tibial supports, and then the corresponding motor performs a predefined flexion–extension cycle that is personalized to the specific patient’s motor function. The system is portable by means of a backpack that contains an embedded computer board, the motor drivers, and the battery. A preliminary biomechanical evaluation of the gait-assistive device used by a female patient with incomplete spinal cord injury at T11 is presented. Results show an increase of gait speed (+24.11%), stride length (+7.41%), and cadence (+15.56%) when wearing the robotic orthoses compared with the case with passive orthoses. Conversely, a decrease of lateral displacement of the center of mass (−19.31%) and step width (−13.37% right step, −8.81% left step) are also observed, indicating gain of balance. The biomechanical assessment also reports an overall increase of gait symmetry when wearing the developed assistive device.