Anabel Martínez Espert

Ms. Anabel Martínez Espert

University of Valencia, Valencia, Spain
+1
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DMDiego Montagud-Martínez
Diego Montagud-Martínez
VFVicente Ferrando
Vicente Ferrando
AEAnabel Martínez Espert
Anabel Martínez Espert
SGSalvador García-Delpech
Salvador García-Delpech
JMJuan A. Monsoriu
Juan A. Monsoriu
Walter D. FurlanWalter D. Furlan
Walter D. Furlan
Most of the new premium models of intraocular lenses for presbyopia correction use diffractive optics in their optical design. The presence of multiple foci and the difference of the diffractive efficiency for different wavelengths have a great impact in the lens optical performance. In this context, there is a limited information available for clinicians to understand the optical principles that differentiate each design and their potential influence on clinical outcomes. Optical bench studies with polychromatic light are necessary to solve this limitation. In this work, a custom made optical bench was employed to assess with polychromatic light the through the focus optical quality of three different IOL designs: trifocal, EDOF effect; and enhanced monofocal. By using different and complimentary approaches: images of the USAF test, axial PSFs and TF-MTFs, each design revealed its intrinsic features, which were not previously reported for these IOLs models in a comparative way. It was found that the chromatic aberration plays a very important role in the performance of each IOL. Our results could help clinicians to understand the optical principle of each lens and also provide useful information for choosing the lens that best suits the needs of the individual patient.

28 April 2023 in Biomedical Optics Express
Verified
Journal Article
Open access
Walter D. FurlanWalter D. Furlan
Walter D. Furlan
AEAnabel Martínez Espert
Anabel Martínez Espert
DMDiego Montagud-Martínez
Diego Montagud-Martínez
VFVicente Ferrando
Vicente Ferrando
SGSalvador García-Delpech
Salvador García-Delpech
JMJuan A. Monsoriu
Juan A. Monsoriu
In this work, we propose a new diffractive trifocal intraocular lens design with focus extension, conceived to provide a high visual performance at intermediate distances. This design is based on a fractal structure known as the “Devil's staircase”. To assess its optical performance, numerical simulations have been performed with a ray tracing program using the Liou-Brennan model eye under polychromatic illumination. The simulated through the focus visual acuity was the merit function employed to test its pupil-dependence and its behavior against decentering. A qualitative assessment of the multifocal intraocular lens (MIOL) was also performed experimentally with an adaptive optics visual simulator. The experimental results confirm our numerical predictions. We found that our MIOL design has a trifocal profile, which is very robust to decentration and has low degree of pupil dependence. It performs better at intermediate distances than at near distances and, for a pupil diameter of 3 mm, it works like an EDoF lens over almost the entire defocus range.

Verified
Journal Article
Open access
PDF file
SGScott García
Scott García
LSLuís Salvá
Luís Salvá
SGSalvador García-Delpech
Salvador García-Delpech
AEAnabel Martínez Espert
Anabel Martínez Espert
VFVicente Ferrando
Vicente Ferrando
DMDiego Montagud-Martínez
Diego Montagud-Martínez
This study aimed to evaluate in vitro performance refractive segmented EDOF intraocular lenses under polychromatic light using an optical bench that complies with the ISO 11979-2 Norm. The through focus modulation transfer function (TF-MTF) of the Femtis Comfort LS-313 MF15 (Oculentis GmbH, Berlin, Germany) IOL was evaluated for IOLs with three different base powers. The effect of the asymmetry of the segmented designs was evaluated with 3 different wavelengths and with polychromatic light at a 3.0 mm and 5.0 mm pupil diameter. It was demonstrated that the TF-MTF curves exhibit a bifocal profile that, in practice, results in an EDOF design. As a consequence of the LCA, the TF-MTF values in white light were lower than in monochromatic light. Images of the USAF test chart were obtained to confirm the prediction of the TF-MTFs. We found that Femtis Comfort is a bifocal low-addition IOL and this fact can result in an EDOF effect which was obtained previously in clinical trials. Moreover, we showed that the base power influences the IOL optical quality, which results as more effective for high powers (hyperopic eyes) than for low powers (myopic eyes). The LCA of the segmented refractive design was very low and presumably not clinically relevant.

Verified
Journal Article
Open access
PDF file
LSLuis Salvá
Luis Salvá
SGScott García
Scott García
SGSalvador García-Delpech
Salvador García-Delpech
AEAnabel Martínez Espert
Anabel Martínez Espert
DMDiego Montagud-Martínez
Diego Montagud-Martínez
VFVicente Ferrando
Vicente Ferrando
Evaluating chromatic aberration for a multifocal intraocular lens (MIOL) in vitro is essential for studying its performance because it helps determine the most appropriate lens for each patient, enhancing surgical outcomes. While refractive MIOLs with angular power variation have shown positive clinical outcomes, studies of these MIOLs on optical benches primarily employed monochromatic green light, neglecting the impact of longitudinal chromatic aberration (LCA) on MIOL performance. To address this gap, we evaluated the through-focus modulation transfer function (TF-MTF) and the point spread function (PSF) of two refractive segmented extended depth of focus intraocular lenses (IOLs) (Femtis Comfort and Precizon Presbyopic), comparing the results with those obtained with two widely known diffractive multifocal intraocular lenses (AcrySof IQ ReSTOR and FineVision Pod F). Measurements of the TF-MTF were conducted using both monochromatic and polychromatic light in a customized optical bench. The refractive designs exhibited distinct haloes in the PSFs. When comparing the refractive and diffractive designs, opposite signs of LCA were observed at near foci. These findings emphasize the influence of the optical design of IOLs on their performance under polychromatic light, providing valuable information for vision care professionals when selecting the most suitable lens for each patient.

25 February 2022 in Photonics
Verified
Journal Article
Open access
PDF file
AEAnabel Martínez Espert
Anabel Martínez Espert
DMDiego Montagud-Martínez
Diego Montagud-Martínez
VFVicente Ferrando
Vicente Ferrando
Walter D. FurlanWalter D. Furlan
Walter D. Furlan
JMJuan A. Monsoriu
Juan A. Monsoriu
In this work, we analyze a proposal of a new intracorneal diffractive lens for presbyopia correction that could allow good, distance, intermediate and near vision. By using an adaptive optics visual simulator, we study the influence of two factors in the inlay performance: the spherical aberration (SA) and the potential errors of in thickness, induced in the manufacturing process. We show that the inlay through-the-focus imaging performance can be customized with the SA value, favoring either distance–intermediate or intermediate–near vision. Moreover, we found that with thickness variations of 10%, the inlay still maintains its trifocal nature.

26 November 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
AEAnabel Martínez Espert
Anabel Martínez Espert
VFVicente Ferrando
Vicente Ferrando
AGAdrián Garmendía-Martínez
Adrián Garmendía-Martínez
FMFrancisco M. Muñoz-Pérez
Francisco M. Muñoz-Pérez
JMJuan A. Monsoriu
Juan A. Monsoriu
Walter D. FurlanWalter D. Furlan
Walter D. Furlan
In this work, we present two new multifocal intraocular lens (MIOL) designs, both based on the silver mean kinoform diffractive lens. We demonstrate that a single aperiodic diffractive profile can be used to create two different MIOLs: one with a kinoform structure and the other with a stepwise profile. Quantitative assessment of the designs was carried out using the through focus modulation transfer function and the area under the modulation transfer function for the prediction of their visual performance. Our results show that both designs exhibit nearly identical optical performance at the design wavelength (λ = 550 nm), though their intrinsic longitudinal chromatic aberration differs significantly. Given that diffractive extended depth of focus (EDoF) intraocular lenses are prone to image degradation due to dysphotopic phenomena, we also compared the halos generated by these two designs and found notable differences in their behavior. Furthermore, under photopic conditions, the proposed lens designs demonstrated the potential to achieve visual acuity values of 0.2 logMAR or better across a vergence range from approximately 0 to 2 D. Finally, to qualitatively assess the behavior of the MIOLs, an objective experimental evaluation was conducted using an adaptive optics visual simulator in a model eye. Experimental results align with the quantitative assessment of the proposed designs.