Martin Ernst Blohm

Dr. Martin Ernst Blohm

Division of Neonatology and Paediatric Critical Care Medicine, University Medical Center Hamburg – Eppendorf, Hamburg, Germany
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2014 in Critical Care
Verified
Journal Article
Open access
PDF file
MBMartin Ernst Blohm
Martin Ernst Blohm
DODenise Obrecht
Denise Obrecht
JHJana Hartwich
Jana Hartwich
GMGoetz Christoph Mueller
Goetz Christoph Mueller
JKJan F. Kersten
Jan F. Kersten
DSDominique Singer
Dominique Singer
Introduction: Electrical velocimetry (EV) is a type of impedance cardiography, and is a non-invasive and continuously applicable method of cardiac output monitoring. Transthoracic echocardiography (TTE) is non-invasive but discontinuous. Methods: We compared EV with TTE in pediatric intensive care patients in a prospective single-center observational study. Simultaneous, coupled, left ventricular stroke volume measurements were performed by EV using an Aesculon® monitor and TTE (either via trans-aortic valve flow velocity time integral [EVVTI], or via M-mode [EVMM]). H0: bias was less than 10% and the mean percentage error (MPE) was less than 30% in Bland–Altman analysis between EV and TTE. If appropriate, data were logarithmically transformed prior to Bland–Altman analysis. Results: A total of 72 patients (age: 2 days to 17 years; weight: 0.8 to 86 kg) were analyzed. Patients were divided into subgroups: organ transplantation (OTX, n =28), sepsis or organ failure (SEPSIS, n =16), neurological patients (NEURO, n =9), and preterm infants (PREM, n =26); Bias/MPE for EVVTI was 7.81%/26.16%. In the EVVTI subgroup analysis for OTX, NEURO, and SEPSIS, bias and MPE were within the limits of H0, whereas the PREM subgroup had a bias/MPE of 39.00%/46.27%. Bias/MPE for EVMM was 8.07%/37.26% where the OTX and NEURO subgroups were within the range of H0, but the PREM and SEPSIS subgroups were outside the range. Mechanical ventilation, non-invasive continuous positive airway pressure ventilation, body weight, and secondary abdominal closure were factors that significantly affected comparison of the methods. Conclusions: This study shows that EV is comparable with aortic flow-based TTE for pediatric patients.

2 July 2019 in Frontiers in Pediatrics
Verified
Journal Article
Open access
PDF file
MBMartin Ernst Blohm
Martin Ernst Blohm
FAFlorian Arndt
Florian Arndt
GFGlenn M. Fröschle
Glenn M. Fröschle
NLNora Langenbach
Nora Langenbach
JSJan Sandig
Jan Sandig
DSDominique Singer
Dominique Singer
Background: Several cardiovascular biomarkers have regulatory functions in perinatal physiology. Aim: This study aimed to analyze the feto-maternal distribution pattern of biomarkers in samples of amniotic fluid, umbilical arterial blood, umbilical venous blood, and maternal blood samples, and to establish reference values. Each linked sample set consisted of the combined samples obtained in an individual pregnancy. Study design: We performed a prospective, observational, cross-sectional, single-center study. Subjects: The sample cohort included 189 neonates who were born to 170 mothers. A total of 162/189 neonates were full term and 129/189 were delivered by elective cesarean section. Outcome measures: Midregional pro-adrenomedullin (MRproADM [nmol/L]), midregional pro-atrial natriuretic peptide (MRproANP [pmol/L]), brain natriuretic peptide (BNP [pg/mL]), N-terminal pro-brain natriuretic peptide (NTproBNP [pg/mL]), copeptin [pmol/L], and high-sensitive troponin I (hsTnI [pg/mL]) levels were measured. Results: In singleton, full-term, primary cesarean deliveries (n = 91), biomarker levels (median, [IQR]) at delivery were as follows. MRproADM levels in umbilical arterial blood/umbilical venous blood/amniotic fluid/maternal blood were 0.88 (0.20)/0.95 (0.18)/2.80 (1.18)/1.10 (0.54), respectively. MRproANP levels were 214.23 (91.38)/216.03 (86.15)/0.00 (3.82)/50.67 (26.81), respectively. BNP levels were 14.60 (25.18)/22.08 (18.91)/7.15 (6.01)/6.20 (18.23), respectively. NTproBNP levels were 765.48 (555.24)/816.45 (675.71)/72.03 (55.58)/44.40 (43.94), respectively. Copeptin levels were 46.17 (290.42)/5.54 (9.08)/9.97 (7.44)/4.61 (4.59), respectively. Levels of hsTnI were 6.20 (4.25)/5.60 (5.01)/0.45 (1.73)/2.50 (2.40), respectively. Conclusion: We determined reference values for biomarkers in term neonates delivered by primary cesarean section in amniotic fluid, umbilical arterial and venous blood, and maternal blood. Biomarkers in the fetal circulation appear to be of primary fetal origin, except for MRproADM.

25 September 2021 in Children
Verified
Journal Article
Open access
PDF file
AAAhmed Talal Aboalqez
Ahmed Talal Aboalqez
PDPhilipp Deindl
Philipp Deindl
CEChinedu Ulrich Ebenebe
Chinedu Ulrich Ebenebe
DSDominique Singer
Dominique Singer
MBMartin Ernst Blohm
Martin Ernst Blohm
An adequate blood volume is important for neonatal adaptation. The study objective was to quantify the cumulative iatrogenic blood loss in very low birth weight (VLBW) infants by blood sampling and the necessity of packed red cell transfusions from birth to discharge from the hospital. In total, 132 consecutive VLBW infants were treated in 2019 and 2020 with a median birth weight of 1180 g (range 370–1495 g) and a median length of stay of 54 days (range 0–154 days) were included. During the initial four weeks of life, the median absolute amount of blood sampling was 16.5 mL (IQR 12.3–21.1 mL), sampling volume was different with 14.0 mL (IQR 12.1–16.2 mL) for non-transfused infants and 21.6 mL (IQR 17.5–29.4 mL) for transfused infants. During the entire length of stay, 31.8% of the patients had at least one transfusion. In a generalized logistic regression model, the cumulative amount of blood sampling (p < 0.01) and lower hematocrit at birth (p = 0.02) were independent predictors for the necessity of blood transfusion. Therefore, optimized patient blood management in VLBW neonates should include sparse blood sampling to avoid iatrogenic blood loss.

4 February 2016 in Early Human Development
Verified
Journal Article
Closed access
MBMartin Ernst Blohm
Martin Ernst Blohm
FAFlorian Arndt
Florian Arndt
JSJan Sandig
Jan Sandig
WDWerner Diehl
Werner Diehl
TZTanja Zeller
Tanja Zeller
JWJochen Weil
Jochen Weil

12 April 2016 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
MBMartin Ernst Blohm
Martin Ernst Blohm
JHJana Hartwich
Jana Hartwich
DODenise Obrecht
Denise Obrecht
JKJan Felix Kersten
Jan Felix Kersten
DSDominique Singer
Dominique Singer

14 December 2019 in Pediatric Nephrology
Verified
Journal Article
Closed access
PDF file
MWMeike Wilken
Meike Wilken
JOJun Oh
Jun Oh
HPHans O. Pinnschmidt
Hans O. Pinnschmidt
DSDominique Singer
Dominique Singer
MBMartin Ernst Blohm
Martin Ernst Blohm