Yuhong Wang

Prof. Dr. Yuhong Wang

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2024 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
XZXu Zhou
Xu Zhou
YWYuhong Wang
Yuhong Wang
YSYunxiang Shi
Yunxiang Shi
QJQiliang Jiang
Qiliang Jiang
CZChenyu Zhou
Chenyu Zhou
Zongsheng ZhengZongsheng Zheng
Zongsheng Zheng
A phasor measurement unit (PMU) is the core measurement component of power system monitoring and analysis. The placement of PMUs directly impacts the state estimation confidence, and hence the optimal PMU placement (OPP), that, minimizing the number of PMUs and ensuring system observability, is appealing to power engineers. However, the current observability analysis mostly relies on topological methods, which cannot reflect the influence of the operating environment. Moreover, intricate OPP models are driving higher demand for efficient solvers. Confronting these challenges, we propose a reinforcement learning graph convolutional network-deep deterministic policy gradient algorithm-based OPP strategy, which effectively captures the system graph structure and PMU state, thereby independently identifying the PMUs value. Furthermore, the degree of system observability is considered, and three observability quantitative indicators are proposed in the OPP strategy, which will enhance the confidence of the perceived state under complex operating environment. The effectiveness of the proposed strategy have been validated in multiple test systems.

13 May 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Zongsheng ZhengZongsheng Zheng
Zongsheng Zheng
YXYijun Xu
Yijun Xu
LMLamine Mili
Lamine Mili
ZLZhigang Liu
Zhigang Liu
MKMert Korkali
Mert Korkali
YWYuhong Wang
Yuhong Wang
Serving as a prerequisite to power system dynamic state estimation, the observability analysis of a power system dynamic model has recently attracted the attention of many power engineers. However, because this model is typically nonlinear and large-scale, the analysis of its observability is a challenge to the traditional derivative-based methods. Indeed, the linear-approximation-based approach may provide unreliable results while the nonlinear-technique-based approach inevitably faces extremely complicated derivations. Furthermore, because power systems are intrinsically stochastic, the traditional deterministic approaches may lead to inaccurate observability analyses. Facing these challenges, we propose a novel polynomial-chaos-based derivative-free observability analysis approach that not only is free of any linear approximations, but also accounts for the stochasticity of the dynamic model while bringing a low implementation complexity. Furthermore, this approach enables us to quantify the degree of observability of a stochastic model, what conventional deterministic methods cannot do. The excellent performance of the proposed method has been demonstrated by performing extensive simulations using a synchronous generator model with IEEE-DC1A exciter and the TGOV1 turbine governor.

1 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
YWYuhong Wang
Yuhong Wang
Lei ChenLei Chen
Lei Chen
HZHong Zhou
Hong Zhou
XZXu Zhou
Xu Zhou
Zongsheng ZhengZongsheng Zheng
Zongsheng Zheng
LLLiang Lu
Liang Lu
Compared with static transmission network expansion planning (TNEP), multi-stage TNEP is more in line with the actual situation, but the modeling is also more complicated. This paper proposes a new multi-stage TNEP method based on the deep Q-network (DQN) algorithm, which can solve the multi-stage TNEP problem based on a static TNEP model. The main purpose of this research is to provide grid planners with a simple and effective multi-stage TNEP method, which is able to flexibly adjust the network expansion scheme without replanning. The proposed method takes into account the construction sequence of lines in the planning and completes the adaptive planning of lines by utilizing the interactive learning characteristics of the DQN algorithm. In order to speed up the learning efficiency of the algorithm and enable the agent to have a better judgment on the reward of the line-building action, the prioritized experience replay (PER) strategy is added to the DQN algorithm. In addition, the economy, reliability, and flexibility of the expansion scheme are considered in order to evaluate the scheme more comprehensively. The fault severity of equipment is considered on the basis of the Monte Carlo method to obtain a more comprehensive system state simulation. Finally, extensive studies are conducted with IEEE 24-bus reliability test system, and the computational results demonstrate the effectiveness and adaptability of the proposed flexible TNEP method.

5 January 2022 in Electronics
Verified
Journal Article
Open access
PDF file
CGChunsheng Guo
Chunsheng Guo
YWYuhong Wang
Yuhong Wang
JLJianquan Liao
Jianquan Liao
In a bipolar DC distribution network, the unbalanced load resistance, line resistance and renewable energy source will cause an unbalanced current for each node of the neutral line and lead to its unbalanced voltage. This is a unique power quality problem of bipolar DC distribution networks, which will increase the power loss in the network and lead to overcurrent protection of the neutral line in serious cases. A voltage balancer can be adopted to suppress the unbalanced voltage and current. However, the existing literature does not consider the consistent application of multiple voltage balancers in a multi-node bipolar DC distribution network. This paper creatively proposes a consensus control topology combining primary control and secondary control in a radial multi-node bipolar DC distribution network with voltage balancers. In this paper, the formulas for the positive and negative current and duty cycle of a bipolar DC distribution network with voltage balancers are derived, and improved voltage balancer modeling based on a consensus algorithm is built. The radial multi-node bipolar DC distribution network is established in MATLAB/Simulink. The simulation results compare the consensus control with the traditional droop control and verify the effectiveness of the new control structure with voltage balancers.

18 June 2024 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YWYuhong Wang
Yuhong Wang
BZBingjie Zhai
Bingjie Zhai
Shilin GaoShilin Gao
Shilin Gao
YGYitan Guo
Yitan Guo
CSChen Shen
Chen Shen
YSYankan Song
Yankan Song
The parameters of power system electromagnetic transient (EMT) model have great influences on the accuracy of EMT simulation. This paper proposes a data-driven parameter calibration method based on Sobol sensitivity analysis and Gaussian mixture model (GMM) to calibrate the parameters of the power system EMT models. First, the dominant parameters of the power system EMT model are derived based on the derivative-free Sobol sensitivity analysis method. Then, the GMM that describes the relationship between the dominant parameters and the EMT simulation errors is established and solved. Finally, an improved particle swarm optimization algorithm is adopted to optimize the EMT simulation errors and the values of the parameters are obtained according to the minimum error and the conditional probability invariance of GMM. The test results on four different systems show that the proposed method can accurately calibrate all dominant parameters of the EMT models of the various power systems.

3 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
TZTong Zhu
Tong Zhu
GHGechao Huang
Gechao Huang
XOXuetong Ouyang
Xuetong Ouyang
WZWeilin Zhang
Weilin Zhang
YWYanfeng Wang
Yanfeng Wang
Shilin GaoShilin Gao
Shilin Gao
In photovoltaic grid-connected systems, the interaction between grid-connected inverters and the grid may cause harmonic oscillation, which severely affects the normal operation of the system. To improve the quality of the output electrical energy, photovoltaic grid-connected systems often use LCL filters as output filters to filter out high-frequency harmonics. Taking the three-phase LCL-type photovoltaic grid-connected inverter system as an example, this paper addresses the issue of harmonic resonance. Firstly, based on the harmonic linearization method and considering the impact of the coupling compensation term on the grid-side voltage, a modular positive and negative sequence impedance modeling method is proposed, which simplifies the secondary modeling process of the converter under feedback control. Then, the stability analysis is conducted using the Nyquist criterion, revealing the mechanism of high-frequency resonance in photovoltaic grid-connected systems. Furthermore, this paper delves into the impact of changes in system parameters on impedance characteristics and system stability. The results indicate that the proportional coefficient of the internal loop current controller has a significant influence on system impedance characteristics. Additionally, this paper proposes an active damping design method that combines lead correction and capacitor current feedback to impedance-reconstruct the easily oscillating frequency band. Finally, the effectiveness of this method is verified in the simulation platform. Simulation results confirm the effectiveness of this method in suppressing harmonic resonance while maintaining rapid dynamic response.