Nourelhuda Mohamed

Ms. Nourelhuda Mohamed

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
MMManal Mohamed
Manal Mohamed
NMNourelhuda Mohamed
Nourelhuda Mohamed
Jae Gwan KimJae Gwan Kim
Jae Gwan Kim
Sleep is a fundamental aspect of daily life, profoundly impacting mental and emotional well-being. Optimal sleep quality is vital for overall health and quality of life, yet many individuals struggle with sleep-related difficulties. In the past, polysomnography (PSG) has served as the gold standard for assessing sleep, but its bulky nature, cost, and the need for expertise has made it cumbersome for widespread use. By recognizing the need for a more accessible and user-friendly approach, wearable home monitoring systems have emerged. EEG technology plays a pivotal role in sleep monitoring, as it captures crucial brain activity data during sleep and serves as a primary indicator of sleep stages and disorders. This review provides an overview of the most recent advancements in wearable sleep monitoring leveraging EEG technology. We summarize the latest EEG devices and systems available in the scientific literature, highlighting their design, form factors, materials, and methods of sleep assessment. By exploring these developments, we aim to offer insights into cutting-edge technologies, shedding light on wearable EEG sensors for advanced at-home sleep monitoring and assessment. This comprehensive review contributes to a broader perspective on enhancing sleep quality and overall health using wearable EEG sensors.

19 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MMManal Mohamed
Manal Mohamed
EJEunjung Jo
Eunjung Jo
NMNourelhuda Mohamed
Nourelhuda Mohamed
MKMinhee Kim
Minhee Kim
JYJeong-Dae Yun
Jeong-Dae Yun
Jae Gwan KimJae Gwan Kim
Jae Gwan Kim
In this study, a fully integrated electroencephalogram/functional near-infrared spectroscopy (EEG/fNIRS) brain monitoring system was designed to fulfill the demand for a miniaturized, light-weight, low-power-consumption, and low-cost brain monitoring system as a potential tool with which to screen for brain diseases. The system is based on the ADS1298IPAG Analog Front-End (AFE) and can simultaneously acquire two-channel EEG signals with a sampling rate of 250 SPS and six-channel fNIRS signals with a sampling rate of 8 SPS. AFE is controlled by Teensy 3.2 and powered by a lithium polymer battery connected to two protection circuits and regulators. The acquired EEG and fNIRS signals are monitored and stored using a Graphical User Interface (GUI). The system was evaluated by implementing several tests to verify its ability to simultaneously acquire EEG and fNIRS signals. The implemented system can acquire EEG and fNIRS signals with a CMRR of −115 dB, power consumption of 0.75 mW/ch, system weight of 70.5 g, probe weight of 3.1 g, and a total cost of USD 130. The results proved that this system can be qualified as a low-cost, light-weight, low-power-consumption, and fully integrated EEG/fNIRS brain monitoring system.

12 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
NMNourelhuda Mohamed
Nourelhuda Mohamed
HKHyun-Seok Kim
Hyun-Seok Kim
KKKyu-Min Kang
Kyu-Min Kang
MMManal Mohamed
Manal Mohamed
SKSung-Hoon Kim
Sung-Hoon Kim
Jae Gwan KimJae Gwan Kim
Jae Gwan Kim
In surgeries where general anesthesia is required, the auscultation of heart and lung sounds is essential to provide information on the patient’s cardiorespiratory system. Heart and lung sounds can be recorded using an esophageal stethoscope; however, there is huge background noise when this device is used in an operating room. In this study, a digital esophageal stethoscope system was designed. A 3D-printed case filled with Polydimethylsiloxane material was designed to hold two electret-type microphones. One of the microphones was placed inside the printed case to collect the heart and lung sound signals coming out from the patient through the esophageal catheter, the other was mounted on the surface of the case to collect the operating room sounds. A developed adaptive noise canceling algorithm was implemented to remove the operating room noise corrupted with the main heart and lung sound signals and the output signal was displayed on software application developed especially for this study. Using the designed case, the noise level of the signal was reduced to some extent, and by adding the adaptive filter, further noise reduction was achieved. The designed system is lightweight and can provide noise-free heart and lung sound signals.

15 December 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
MMManal Mohamed
Manal Mohamed
NMNourelhuda Mohamed
Nourelhuda Mohamed
Jae Gwan KimJae Gwan Kim
Jae Gwan Kim
Detecting and tracking the preclinical stages of Alzheimer’s disease (AD) is now of particular interest due to the aging of the world’s population. AD is the most common cause of dementia, affecting the daily lives of those afflicted. Approaches in development can accelerate the evaluation of the preclinical stages of AD and facilitate early treatment and the prevention of symptom progression. Shifts in P300 amplitude and latency, together with neuropsychological assessments, could serve as biomarkers in the early screening of declines in cognitive abilities. In this study, we investigated the ability of the P300 indices evoked during a visual oddball task to differentiate pre-clinically diagnosed participants from normal healthy adults (HCs). Two preclinical stages, named asymptomatic AD (AAD) and prodromal AD (PAD), were included in this study, and a total of 79 subjects participated, including 35 HCs, 22 AAD patients, and 22 PAD patients. A mixed-design ANOVA test was performed to compare the P300 indices among groups during the processing of the target and non-target stimuli. Additionally, the correlation between these neurophysiological variables and the neuropsychological tests was evaluated. Our results revealed that neither the peak amplitude nor latency of P300 can distinguish AAD from HCs. Conversely, the peak latency of P300 can be used as a biomarker to differentiate PAD from AAD and HCs. The correlation results revealed a significant relationship between the peak latency of P300 and memory domain tasks, showing that less time-demanding neuropsychological assessments can be used. In summary, our findings showed that a combination of P300 latency and memory-requiring tasks can be used as an efficient biomarker to differentiate individuals with AAD from HCs.

4 June 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
NMNourelhuda Mohamed
Nourelhuda Mohamed
HKHyun-Seok Kim
Hyun-Seok Kim
MMManal Mohamed
Manal Mohamed
KKKyu-Min Kang
Kyu-Min Kang
SKSung-Hoon Kim
Sung-Hoon Kim
Jae Gwan KimJae Gwan Kim
Jae Gwan Kim
Meticulous monitoring for cardiovascular systems is important for postoperative patients in postanesthesia or the intensive care unit. The continuous auscultation of heart and lung sounds can provide a valuable information for patient safety. Although numerous research projects have proposed the design of continuous cardiopulmonary monitoring devices, they primarily focused on the auscultation of heart and lung sounds and mostly served as screening tools. However, there is a lack of devices that could continuously display and monitor the derived cardiopulmonary parameters. This study presents a novel approach to address this need by proposing a bedside monitoring system that utilizes a lightweight and wearable patch sensor for continuous cardiovascular system monitoring. The heart and lung sounds were collected using a chest stethoscope and microphones, and a developed adaptive noise cancellation algorithm was implemented to remove the background noise corrupted with those sounds. Additionally, a short-distance ECG signal was acquired using electrodes and a high precision analog front end. A high-speed processing microcontroller was used to allow real-time data acquisition, processing, and display. A dedicated tablet-based software was developed to display the acquired signal waveforms and the processed cardiovascular parameters. A significant contribution of this work is the seamless integration of continuous auscultation and ECG signal acquisition, thereby enabling the real-time monitoring of cardiovascular parameters. The wearability and lightweight design of the system were achieved through the use of rigid–flex PCBs, which ensured patient comfort and ease of use. The system provides a high-quality signal acquisition and real-time monitoring of the cardiovascular parameters, thus proving its potential as a health monitoring tool.

25 September 2025 in Materials
Verified
Journal Article
Open access
PDF file
NMNourelhuda Mohamed
Nourelhuda Mohamed
MMManal Mohamed
Manal Mohamed
Jae Gwan KimJae Gwan Kim
Jae Gwan Kim
This study investigates the acoustic performance of Ecoflex™ 00-35, a highly flexible silicone rubber, for use in soft and adaptable vibration and noise control systems. Under normal conditions, Ecoflex™ 00-35 consists of two components—Part A and Part B—which are mixed and cured at room temperature to form an elastomer. In this study, curing parameters such as the A/B mixing ratio, thinning agent addition, and curing pressure were varied to examine their effects on acoustic behavior. The microstructure of the prepared samples was analyzed using scanning electron microscopy (SEM), while sound absorption properties were measured using impedance tubes. Test results demonstrated that modifying curing parameters, applying vacuum, and incorporating a thinning agent increased the average cell diameter, leading to the fabrication of a moderate sound absorber with a sound absorption coefficient ranging from 0.35 to 0.60 in the low- to mid-frequency ranges. Further enhancement in low-frequency absorption was achieved by applying low pressure for a short duration, allowing cell expansion. In contrast, the addition of a thinning agent significantly improved absorption at higher frequencies. These findings highlight the influence of processing conditions on the acoustic behavior of soft silicone elastomers and provide valuable insights into their structure–property relationships. Ultimately, this study contributes to the development of advanced materials for acoustic damping and noise control applications.