Ki-Young Shin

Dr. Ki-Young Shin

korea electrotechnology research institute
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2011
Verified
Conference Paper
Closed access
KSKi-Young Shin
Ki-Young Shin
SJSeung Oh Jin
Seung Oh Jin
SYSu Hyun Youn
Su Hyun Youn
SJSu Bin Joo
Su Bin Joo
YJYo Han Jo
Yo Han Jo
YHYoung Huh
Young Huh
Pulse diagnosis, which is one of methods of diagnosis, is an important factor in oriental medicine. However, a problem in diagnosis with the pulse is that there is no objective standard. Therefore, the practitioners pass on the skill and students learn about pulse diagnosis as a method that depends on speech. In this study, the electronic pulse wave reproduction apparatus, which is an objective and accurate means for measuring the pulse, was developed. The previous model reproduced the pulse wave in one part of the point, but it was made by using three pairs of voice coil motors (VCM) in order to similarly express the three parts of the pulse: Cun, Guan and Chi. To evaluate this system, the output of the pulse wave was confirmed in order to reproduce the pulse wave with these settings. Consequently, the targets for slow pulse and rapid pulse have a 7 ms standard deviation, which is within the error tolerance. A voltage value of H1, utilized to verify vacuous pulse and the replete pulse, has a standard deviation range of 4.7-5.4 mV. This system, which is similar to a person's pulse diagnosis, can be used to educate others in pulse diagnosis both quantitatively and scientifically.

1 August 2010 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
KSKi-Young Shin
Ki-Young Shin
SJSung Chae Jeon
Sung Chae Jeon
KNKi-Chang Nam
Ki-Chang Nam
YHYoung Huh
Young Huh
In this study, we developed an array sensor module to measure pulse wave of radial artery. To measure pressure, this module contains 7 piezoresistive sensors of the size of 1×1 mm. This sensor module is composed of a PCB for bonding sensor, PCB guide for wiring, silicon guide to keep its shape while PDMS coating, and PDMS layer protect fragile sensor and wire while faithfully transmitting the pressure of the patient's skin to the sensor. To test characteristic of pressure sensors in the sensor module, intra-chamber pressure was raised in 20mmHg step from 60mmHg to 220mmHg. The coefficient of determinant was r 2 >0.999. When the radial artery's pulse wave with developed sensor module was measured, pulse wave is clearly detected. In this study, developed array sensor module is appropriate to measure pulse wave.

1 February 2017 in ETRI Journal
Verified
Journal Article
Open access
PDF file
SYSu Hyun Youn
Su Hyun Youn
KSKi-Young Shin
Ki-Young Shin
ACAhnryul Choi
Ahnryul Choi
JMJoung Hwan Mun
Joung Hwan Mun
Ultrasonic surgical devices are routinely used for surgical procedures. The incision and coagulation of tissue generate a temperature of 40 °C–150 °C and depend on the controllable output power level of the surgical device. Recently, research on the classification of grasped tissues to automatically control the power level was published. However, this research did not consider the specific characteristics of the surgical device, tissue denaturalization, and so on. Therefore, this research proposes a robust algorithm that simulates noise to resemble real situations and classifies tissue using conventional classifier algorithms. In this research, the bioimpedance spectrum for six tissues (liver, large intestine, kidney, lung, muscle, and fat) is measured, and five classifier algorithms are used. A signal-to-noise ratio of additive white Gaussian noise diversifies the testing sets, and as a result, each classifier's performance exhibits a difference. The k-nearest neighbors algorithm shows the highest classification rate of 92.09% ( p<0.01 ) and a standard deviation of 1.92%, which confirms high reproducibility.