Elizabeth Fischer

Ms. Elizabeth Fischer


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2012 in Current Protocols in Microbiology
Verified
Journal Article
Open access
PDF file
EFElizabeth Fischer
Elizabeth Fischer
BHBryan T. Hansen
Bryan T. Hansen
VNVinod Nair
Vinod Nair
FHForrest H. Hoyt
Forrest H. Hoyt
DDDavid W. Dorward
David W. Dorward
Scanning electron microscopy (SEM) remains distinct in its ability to allow topographical visualization of structures. Key elements to consider for successful examination of biological specimens include appropriate preparative and imaging techniques. Chemical processing induces structural artifacts during specimen preparation, and several factors need to be considered when selecting fixation protocols to reduce these effects while retaining structures of interest. Particular care for proper dehydration of specimens is essential to minimize shrinkage and is necessary for placement under the high‐vacuum environment required for routine operation of standard SEMs. Choice of substrate for mounting and coating specimens can reduce artifacts known as charging, and a basic understanding of microscope settings can optimize parameters to achieve desired results. This unit describes fundamental techniques and tips for routine specimen preparation for a variety of biological specimens, preservation of labile or fragile structures, immune‐labeling strategies, and microscope imaging parameters for optimal examination by SEM. Curr. Protoc. Microbiol. 25:2B.2.1‐2B.2.47. © 2012 by John Wiley & Sons, Inc.

9 September 2021 in Viruses
Verified
Journal Article
Open access
PDF file
THTed Hackstadt
Ted Hackstadt
ACAbhilash Chiramel
Abhilash Chiramel
FHForrest H. Hoyt
Forrest H. Hoyt
BWBrandi Williamson
Brandi Williamson
CDCheryl A. Dooley
Cheryl A. Dooley
EFElizabeth Fischer
Elizabeth Fischer
A variety of immunolabeling procedures for both light and electron microscopy were used to examine the cellular origins of the host membranes supporting the SARS-CoV-2 replication complex. The endoplasmic reticulum has long been implicated as a source of membrane for the coronavirus replication organelle. Using dsRNA as a marker for sites of viral RNA synthesis, we provide additional evidence supporting ER as a prominent source of membrane. In addition, we observed a rapid fragmentation of the Golgi apparatus which is visible by 6 h and complete by 12 h post-infection. Golgi derived lipid appears to be incorporated into the replication organelle although protein markers are dispersed throughout the infected cell. The mechanism of Golgi disruption is undefined, but chemical disruption of the Golgi apparatus by brefeldin A is inhibitory to viral replication. A search for an individual SARS-CoV-2 protein responsible for this activity identified at least five viral proteins, M, S, E, Orf6, and nsp3, that induced Golgi fragmentation when expressed in eukaryotic cells. Each of these proteins, as well as nsp4, also caused visible changes to ER structure as shown by correlative light and electron microscopy (CLEM). Collectively, these results imply that specific disruption of the Golgi apparatus is a critical component of coronavirus replication.

8 May 2024 in Current Protocols
Verified
Journal Article
Open access
EFElizabeth Fischer
Elizabeth Fischer
BHBryan T. Hansen
Bryan T. Hansen
VNVinod Nair
Vinod Nair
FHForrest H. Hoyt
Forrest H. Hoyt
CSCindi L. Schwartz
Cindi L. Schwartz
DDDavid W. Dorward
David W. Dorward
Scanning electron microscopy (SEM) remains distinct in its ability to allow topographical visualization of structures. Key elements to consider for successful examination of biological specimens include appropriate preparative and imaging techniques. Chemical processing induces structural artifacts during specimen preparation, and several factors need to be considered when selecting fixation protocols to reduce these effects while retaining structures of interest. Particular care for proper dehydration of specimens is essential to minimize shrinkage and is necessary for placement under the high‐vacuum environment required for routine operation of standard SEMs. Choice of substrate for mounting and coating specimens can reduce artifacts known as charging, and a basic understanding of microscope settings can optimize parameters to achieve desired results. This article describes fundamental techniques and tips for routine specimen preparation for a variety of biological specimens, preservation of labile or fragile structures, immune‐labeling strategies, and microscope imaging parameters for optimal examination by SEM. © 2024 The Authors. Current Protocols published by Wiley Periodicals LLC.Basic Protocol 1: Chemical preparative techniques for preservation of biological specimens for examination by SEMAlternate Protocol 1: Practical considerations for the preparation of soft tissuesAlternate Protocol 2: Removal of debris from the exoskeleton of invertebratesAlternate Protocol 3: Fixation of colonies grown on agar platesAlternate Protocol 4: Stabilization of polysaccharide structures with alcian blue and lysineAlternate Protocol 5: Preparation of non‐adherent particulates in solution for SEMSupport Protocol 1: Application of thin layer of adhesive on substrate to improve adherenceSupport Protocol 2: Poly‐L‐lysine coating specimen substrates for improved adherenceSupport Protocol 3: Microwave processing of biological specimens for examination by SEMBasic Protocol 2: Critical point drying of specimensAlternate Protocol 6: Chemical alternative to critical point dryingBasic Protocol 3: Sputter coatingAlternate Protocol 7: Improved bulk conductivity through “OTOTO”Basic Protocol 4: Immune‐labeling strategiesAlternate Protocol 8: Immune‐labeling internal antigens with small gold probesAlternate protocol 9: Quantum dot or fluoronanogold preparations for correlative techniquesBasic Protocol 5: Exposure of internal structures by mechanical fracturingBasic Protocol 6: Exposure of internal structures of tissues by fracturing with liquid nitrogenBasic Protocol 7: Anaglyph production from stereo pairs to produce 3D images

13 January 2023 in Science Immunology
Verified
Journal Article
Closed access
KLKaren Laky
Karen Laky
JKJessica L. Kinard
Jessica L. Kinard
JLJenny Min Li
Jenny Min Li
IMIan N. Moore
Ian N. Moore
JLJustin Lack
Justin Lack
PFPamela A Frischmeyer-Guerrerio
Pamela A Frischmeyer-Guerrerio
Allergic diseases are a global health challenge. Individuals harboring loss-of-function variants in transforming growth factor–β receptor (TGFβR) genes have an increased prevalence of allergic disorders, including eosinophilic esophagitis. Allergic diseases typically localize to mucosal barriers, implicating epithelial dysfunction as a cardinal feature of allergic disease. Here, we describe an essential role for TGFβ in the control of tissue-specific immune homeostasis that provides mechanistic insight into these clinical associations. Mice expressing a TGFβR1 loss-of-function variant identified in atopic patients spontaneously develop disease that clinically, immunologically, histologically, and transcriptionally recapitulates eosinophilic esophagitis. In vivo and in vitro, TGFβR1 variant–expressing epithelial cells are hyperproliferative, fail to differentiate properly, and overexpress innate proinflammatory mediators, which persist in the absence of lymphocytes or external allergens. Together, our results support the concept that TGFβ plays a fundamental, nonredundant, epithelial cell–intrinsic role in controlling tissue-specific allergic inflammation that is independent of its role in adaptive immunity.

7 May 2014 in The American Journal of Tropical Medicine and Hygiene
Verified
Journal Article
Closed access
RCRobert W. Cross
Robert W. Cross
BWBradley Waffa
Bradley Waffa
AFAshley Freeman
Ashley Freeman
CRClaudia Riegel
Claudia Riegel
LMLina M. Moses
Lina M. Moses
DBDaniel G. Bausch
Daniel G. Bausch
Seoul virus, an Old World hantavirus, is maintained in brown rats and causes a mild form of hemorrhagic fever with renal syndrome (HFRS) in humans. We captured rodents in New Orleans, Louisiana and tested them for the presence of Old World hantaviruses by reverse transcription polymerase chain reaction (RT-PCR) with sequencing, cell culture, and electron microscopy; 6 (3.4%) of 178 rodents captured—all brown rats—were positive for a Seoul virus variant previously coined Tchoupitoulas virus, which was noted in rodents in New Orleans in the 1980s. The finding of Tchoupitoulas virus in New Orleans over 25 years since its first discovery suggests stable endemicity in the city. Although the degree to which this virus causes human infection and disease remains unknown, repeated demonstration of Seoul virus in rodent populations, recent cases of laboratory-confirmed HFRS in some US cities, and a possible link with hypertensive renal disease warrant additional investigation in both rodents and humans.

18 July 2012 in FEMS Yeast Research
Verified
Journal Article
Open access
PDF file
PNPopchai Ngamskulrungroj
Popchai Ngamskulrungroj
YCYun C Chang
Yun C Chang
BHBryan Hansen
Bryan Hansen
CBCliff Bugge
Cliff Bugge
EFElizabeth Fischer
Elizabeth Fischer
KKKyung J. Kwon-Chung
Kyung J. Kwon-Chung
Cryptococcus neoformans, an opportunistic fungal pathogen, manifests an intrinsic adaptive mechanism of resistance toward fluconazole (FLC) terme