Vladimir Kolotov

Vladimir Kolotov


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

6 May 2020 in Journal of Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
VKVladimir Kolotov
Vladimir Kolotov
AZA. V. Zhilkina
A. V. Zhilkina
VSV. I. Shirokova
V. I. Shirokova
NDN. N. Dogadkin
N. N. Dogadkin
IGI. N. Gromyak
I. N. Gromyak
DTD. A. Tyurin
D. A. Tyurin
We developed and tested a high-performance system for the acid mineralization of silicate samples in open vessels of original design with programmable heat treatment conditions. A formalized description of operations in the procedures of the acid mineralization of various silicate samples (ultrabasic, basic, and acidic) is proposed, both on a quantitative and a descriptive level. Problems of ensuring the accuracy of the analysis of geological samples by inductively coupled plasma mass spectrometry are discussed.

1 March 2023 in Journal of Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
VKVladimir Kolotov
Vladimir Kolotov
DDD. N. Dogadkin
D. N. Dogadkin
VZV. E. Zaichik
V. E. Zaichik
VSV. I. Shirokova
V. I. Shirokova
NDN. N. Dogadkin
N. N. Dogadkin
To expand the available tools for the analysis of samples of biological and plant origin of small mass (10–20 mg) using ICP MS, we developed a construction made of three compact teflon reaction minivessels (inserts) of an internal volume of 3 mL, placed in a standard autoclave (EasyPrep) of a volume of 100 cm3 of a MARS-5 microwave system (CEM). The acid digestion of samples in reaction minivessels requires no more than 1.5 mL of highly pure acids. The digestion of samples proceeds in the common gas atmosphere of a standard autoclave filled with a needed volume of acids of pure for analysis grade. The method was tested on reference materials of plants and biological sample. The results obtained are in agreement with the certified values. The developed method ensures the decrease of the detection limits and obtaining new data on the concentrations of B, Ga, Y, Nb, Tl, Bi, and a number of rare-earth elements in the reference materials.

1 September 2021 in Agriculture
Verified
Journal Article
Open access
PDF file
YLYuliya Lavrinenko
Yuliya Lavrinenko
APAnna Plieva
Anna Plieva
Inga ZinicovscaiaInga Zinicovscaia
Inga Zinicovscaia
GHGergana Hristozova
Gergana Hristozova
Marina Vladimirovna FrontasyevaMarina Vladimirovna Frontasyeva
Marina Vladimirovna Frontasyeva
VKVladimir Kolotov
Vladimir Kolotov
Herbal infusions are consumed worldwide owing to their beneficial properties. Cultivated or obtained from the wild, herbal raw plant materials may contain trace elements at various levels. This study relates to the release of beneficial and potentially toxic trace elements from herbal preparations during infusion. The elemental contents of seven commercially available herbal tea products were determined prior to and following two modes of infusion. Teabags (of equal herb content) were infused in 200 mL of boiling bottled water “Holy Spirit” for 15 and 45 min, in glass beakers. The total content of 57 elements including heavy metals, rare earth elements, as well as Th and U, were determined by ICP-MS and ICP-AES. The metals present in the highest concentrations were K, Ca, P, and S. Potassium, Mg, Co, Ni, As, Rb, and Cs had the highest extractability, whereas Ga, Ge, Se, Zr, Nb, Te, Er, Yb, W, Tl, and U had the lowest extractability.

7 March 2015 in Journal of Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
VKVladimir Kolotov
Vladimir Kolotov
DGDmitrii Grozdov
Dmitrii Grozdov
NDN. N. Dogadkin
N. N. Dogadkin
ASA. A. Shiryaev
A. A. Shiryaev
VKV. I. Korobkov
V. I. Korobkov
Previously we have shown that, using the mathematical pixel-by-pixel processing of a series of autoradiographic images of activated samples, analyst can gain information on the distribution of elements in geochemical samples, including large ones. The level of reproducibility in 2D densitometry is the key factor determining the efficiency of such processing. A procedure is developed for obtaining a series of digital autoradiograms using both classical nuclear photodetectors and digital imaging plates; the reproducibility of the results of quantitative densitometry was no worse than 2%. The results obtained on mapping well agree with the data of scanning electron microscopy.

29 July 2011 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
VKVladimir Kolotov
Vladimir Kolotov
DGDmitrii Grozdov
Dmitrii Grozdov
NDN. N. Dogadkin
N. N. Dogadkin