Carbon ion radiotherapy (C-ion RT) offers superior dose conformity in the treatment of deep-seated tumors compared with conventional X-ray therapy. In addition, carbon ion beams have a higher relative biological effectiveness compared with protons or X-ray beams. C-ion RT for the first patient at Gunma University Heavy Ion Medical Center (GHMC) was initiated in March of 2010. The major specifications of the facility were determined based on the experience of clinical treatments at the National Institute of Radiological Sciences (NIRS), with the size and cost being reduced to one-third of those at NIRS. The currently indicated sites of cancer treatment at GHMC are lung, prostate, head and neck, liver, rectum, bone and soft tissue. Between March 2010 and July 2011, a total of 177 patients were treated at GHMC although a total of 100 patients was the design specification during the period in considering the optimal machine performance. In the present article, we introduce the facility set-up of GHMC, including the facility design, treatment planning systems, and clinical preparations.
The history of Compton cameras began with the detection of radiation sources originally for applications in astronomy. A Compton camera is a promising γ-ray detector that operates in the wide energy range of a few tens of keV to MeV. The γ-ray detection method of a Compton camera is based on Compton scattering kinematics, which is used to determine the direction and energy of the γ-rays without using a mechanical collimator. Although the Compton camera was originally designed for astrophysical applications, it was later applied in medical imaging as well. Moreover, its application in environmental radiation measurements is also under study. Although a few review papers regarding Compton cameras have been published, they either focus very specifically on the detectors used in such cameras or the particular applications of Compton cameras. Thus, the aim of this paper is to review the features and types of Compton cameras and introduce their applications, associated imaging algorithms, improvement scopes, and their future aspects.
9 April 2013 in Radiological Physics and Technology
We propose a strategy of individualized image acquisitions and treatment planning for respiratory-gated carbon-ion therapy. We implemented it in clinical treatments for diseases of mobile organs such as lung cancers at the Gunma University Heavy Ion Medical Center in June 2010. Gated computed tomography (CT) scans were used for treatment planning, and four-dimensional (4D) CT scans were used to evaluate motion errors within the gating window to help define the internal margins (IMs) and planning target volume for each patient. The smearing technique or internal gross tumor volume (IGTV = GTV + IM), where the stopping power ratio was replaced with the tumor value, was used for range compensation of moving targets. Dose distributions were obtained using the gated CT images for the treatment plans. The influence of respiratory motion on the dose distribution was verified with the planned beam settings using 4D CT images at some phases within the gating window before the adoption of the plan. A total of 14 lung cancer patients were treated in the first year. The planned margins with the proposed method were verified with clinical X-ray set-up images by deriving setup and internal motion errors. The planned margins were considered to be reasonable compared with the errors, except for large errors observed in some cases.
Background/Aim: This study aimed to establish a setup for ultra-high-dose-rate (FLASH) carbon-ion irradiation, and to conduct the first human cell experiments using FLASH carbon ions. Materials and Methods: A system for FLASH carbon-ion irradiation (1-3 Gy at 13 or 50 keV/μm) was developed. The growth and senescence of HFL1 lung fibroblasts were assessed by crystal violet staining assays and senescence-associated β-galactosidase staining, respectively. Survival of HSGc-C5 cancer cells was assessed by clonogenic assays. Results: The dose rates of carbon ions ranged from 96-195 Gy/s, meeting the definition of FLASH. With both 13 and 50 keV/μm beams, no FLASH sparing effect was observed on the growth suppression and senescence of HFL1 cells, nor on the survival of HSGc-C5 cells. Conclusion: We successfully conducted the first human cell experiments with FLASH carbon ions. No FLASH effect was observed under the conditions examined.