Jean Pierre Ndabakuranye

Mr. Jean Pierre Ndabakuranye

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2022 in Sensors & Diagnostics
Verified
Journal Article
Open access
PDF file
JNJean Pierre Ndabakuranye
Jean Pierre Ndabakuranye
SLShiqiang Li
Shiqiang Li
GBGenia Burchall
Genia Burchall
KFKate Fox
Kate Fox
Terrence J PivaTerrence J Piva
Terrence J Piva
IAI arman Ahnood
I arman Ahnood
We provide a perspective on monitoring the blood bilirubin concentration using simple methods, which are economical and can be adopted in point of care settings. These are a homecare test system, a miniature implant, and a neonatal wearable patch.

13 September 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
JNJean Pierre Ndabakuranye
Jean Pierre Ndabakuranye
ARAnushi E. Rajapaksa
Anushi E. Rajapaksa
GBGenia Burchall
Genia Burchall
SLShiqiang Li
Shiqiang Li
SPsteven prawer
steven prawer
IAI arman Ahnood
I arman Ahnood
As a biomarker for liver disease, bilirubin has been utilized in prognostic scoring systems for cirrhosis. While laboratory-based methods are used to determine bilirubin levels in clinical settings, they do not readily lend themselves to applications outside of hospitals. Consequently, bilirubin monitoring for cirrhotic patients is often performed only intermittently; thus, episodes requiring clinical interventions could be missed. This work investigates the feasibility of measuring bilirubin concentration in whole porcine blood samples using dual-wavelength transmission measurement. A compact and low-cost dual-wavelength transmission measurement setup is developed and optimized to measure whole blood bilirubin concentrations. Using small volumes of whole porcine blood (72 µL), we measured the bilirubin concentration within a range corresponding to healthy individuals and cirrhotic patients (1.2–30 mg/dL). We demonstrate that bilirubin levels can be estimated with a positive correlation (R-square > 0.95) and an accuracy of ±1.7 mg/dL, with higher reliability in cirrhotic bilirubin concentrations (> 4 mg/dL) – critical for high-risk patients. The optical and electronic components utilized are economical and can be readily integrated into a miniature, low-cost, and user-friendly system. This could provide a pathway for point-of-care monitoring of blood bilirubin outside of medical facilities (e.g., patient's home).

20 October 2020 in Advanced Biosystems
Verified
Journal Article
Open access
PDF file
IAI arman Ahnood
I arman Ahnood
RCRoss Cheriton
Ross Cheriton
ABAnne Bruneau
Anne Bruneau
JBJames A. Belcourt
James A. Belcourt
JNJean Pierre Ndabakuranye
Jean Pierre Ndabakuranye
SPsteven prawer
steven prawer
The design and benchtop operation of a wireless miniature epiretinal stimulator implant is reported. The implant is optically powered and controlled using safe illumination at near‐infrared wavelengths. An application‐specific integrated circuit (ASIC) hosting a digital control unit is used to control the implant's electrodes. The ASIC is powered using an advanced photovoltaic (PV) cell and programmed using a single photodiode. Diamond packaging technology is utilized to achieve high‐density integration of the implant optoelectronic circuitry, as well as individual connections between a stimulator chip and 256 electrodes, within a 4.6 mm × 3.7 mm × 0.9 mm implant package. An ultrahigh efficiency PV cell with a monochromatic power conversion efficiency of 55% is used to power the implant. On‐board photodetection circuity with a bandwidth of 3.7 MHz is used for forward data telemetry of stimulation parameters. In comparison to implants which utilize inductively coupled coils, laser power delivery enables a high degree of miniaturization and lower surgical complexity. The device presented combines the benefits of implant miniaturization and a flexible stimulation strategy provided by a dedicated stimulator chip. This development provides a route to fully wireless miniaturized minimally invasive implants with sophisticated functionalities.

31 October 2022 in Biosensors and Bioelectronics: X
Verified
Journal Article
Open access
JNJean Pierre Ndabakuranye
Jean Pierre Ndabakuranye
ANAthavan Nadarajah
Athavan Nadarajah
TNTheophile Niyitanga
Theophile Niyitanga
SPSteven Prawer
Steven Prawer
AAArman Ahnood
Arman Ahnood

27 March 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
JNJean Pierre Ndabakuranye
Jean Pierre Ndabakuranye
SPsteven prawer
steven prawer
IAI arman Ahnood
I arman Ahnood

25 September 2024 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
DNDieudonne Tanue Nde
Dieudonne Tanue Nde
SAsaood ali
saood ali
JNJean Pierre Ndabakuranye
Jean Pierre Ndabakuranye
IHImran Hasan
Imran Hasan
TNTheophile Niyitanga
Theophile Niyitanga
SJSang Woo Joo
Sang Woo Joo