Battery has an important role as energy storage in electricity system utilization such as in electric vehicle and in smart microgrid system. Battery Management System (BMS) is needed to treat the dynamics of energy storage process in the battery in order to improve the performance and extend the life time of battery. In this paper, BMS cell monitoring and protection has been designed and tested for Lithium Ferro Phosphate (LFP) battery cells. The BMS cell monitoring function has been able to measure the battery parameters such as the voltage and current dynamics of each cell. The data taken from the BMS cell monitoring experiment is used to estimate the state of charge (SOC) of battery which is based on coulomb counting with coulomb efficiency ratios. The BMS cell monitoring function has successfully demonstrated the presence of unbalanced cell voltages during both processes of charging and discharging as well. From the analysis, the existence of capacity and energy fades was also investigated for every discharging and charging cycles. Based on the BMS cell protection experiment results, overcharged and over discharged protections have successfully been demonstrated for the battery cells. The charging process is disabled when the voltage of the corresponding battery cell exceeds its high limit (HLIM) at 3.65V, and the battery will be available for charging when all of the cell voltages are below their boundary limits (CAVL) at 3.3V. The discharging process will be disabled when the battery cell voltage is lower than the corresponding low limit (LLIM) at 2.5 V. The battery will be available again when all battery cell voltages are above their discharge available (DAVL) voltage at 2.8V. The proposed BMS cell monitoring and protection has shown its function as a data acquisition system, safety protection, ability to determine and predict the state of charge of the battery, and ability to control the battery charging and discharging.
In this research, we developed an active cell balancing system to improve battery module performance. The active cell balancing system is based on Switched-Capacitor Boost Converter (S-CBC) method which consists of capacitors and DC-DC boost converters. The developed active cell balancing system will select the highest battery cell energy then transferred it to the lowest cell energy. From the analytical result, the optimum energy transferred in the active cell balancing system was using 1.1 F capacitor capacity, 5 Ohm resistance, and 5 Volt of the capacitor upper-lower voltage difference which shows the 0.5 Hz frequency and 50% duty cycle. The active cell balancing system experiment was conducted in two stages using valve regulated lead acid (VLRA) batteries with the nominal voltage 12 Volt and the nominal capacity 7 Ah. The first experiment was conducted by comparing the performance of the active cell balancing system with a conventional switched capacitor circuit in 2 battery series connection which shows that the developed system was 4.6 times faster than the conventional circuit at 0.5 Hz frequency with 81% efficiency. The second experiment was conducted to investigate the battery module performance when discharging process occurred with 1 A applied to 4 battery series connection. The result shows that the voltage differences between battery voltage differences without using cell balancing shows above 0.2 V and continues to expand to 0.8 V and by using the developed system the voltage difference were able to achieved below 0.1 Volt. It also shows 7.5 % performance improvement of the average battery system capacity and energy.
Batteries have an important role in the development of electrical energy utilization, such as in renewable energy and electric vehicles. Batteries with good performance would support the devices which utilized them. Because the amount of energy stored in a battery is limited, so battery getting charging and discharging cycles. Improper charge and discharge process could decrease the battery's performance. Therefore battery management system (BMS) is very necessary so that could maintain performance of the battery at optimum condition. One of the important aspect in BMS is state of charge (SoC), which indicate the amount of energy left in the battery. In this work, SOC estimation calculated using Coulomb Counting method which is calculate and compare the electric charge that came in and came out the battery. Upon Coulomb counting on discharging and charging process, battery's SoC estimated by different ways, namely calculate the Peukert's effect and calculate charging efficiency, respectively. Modified Peukert relationship includes current rate parameters are affecting discharge capacity of a battery. Higher Peukert constant would lead to decreasing of operational battery module voltages. Moreover, it could be studied that Peukert only has an effect in the changes of discharge capacity at zero point of SoC. Furthermore, from experimental result it has been known that energy stored in the battery might be has different deep of discharge depends on Peukert constant.
Electric Vehicle (EV) Batteries must have high reliability to produce durable and sustainable electrical energy. Reliable electric batteries will certainly have high economic value and efficiency. Reliability can be obtained if the system and its supporting are monitored using an integrated and independent system for further analysis and observation. Battery Management System (BMS) is integrated parts of Electric Vehicle, Hybrid Electric Vehicle (HEV), or solar applications e.g. solar power plant. Its functions are to integrate many things such as voltage sampling from cell battery, cells balancing, determine State of Charge (SOC), estimate State of Health (SOH), and predict Remaining Useful Life (RUL). The key technology needed for condition-based maintenance is Prognostic and Health Management. It is a new engineering approach that allows an assessment of the system's health when the system is operating. It combines various scientific disciplines, namely: sensing technology, modern statistics, machine learning, physics of failure, and reliability engineering. It will be combined with Big Data analysis. Big data uses existing technology and contemporary architecture that is designed to efficiently take advantage of the many and varied data. Big data analytics refers to the method of analyzing huge volumes of data, high velocity of data, variety different forms of data, and veracity of uncertainty of data. The main focus in this research is the development of an integrated observation system and the ability to make error predictions. This system consists of error detection, error diagnosis, and integrated prognosis. This research is to implement Big Data analytics Platform to evaluate the reliability level of electric vehicle Battery Management System.
30 April 2019 in Journal of Engineering and Technological Sciences
In this work, a historical data based battery management system (BMS) was successfully developed and implemented using an embedded system for condition monitoring of a battery energy storage system in a smart microgrid. The performance was assessed for 28 days of operating time with a one-minute sampling time. The historical data showed that the maximum temperature increment and the maximum temperature difference between the batteries were 4.5 °C and 2.8 °C. One of the batteries had a high voltage rate of change, i.e. above 3.0 V/min, and its temperature rate of change was very sensitive, even at low voltage rate of changes. This phenomenon tends to indicate problems that may deplete the battery energy storage system's total capacity. The primary findings of this study are that the voltage and temperature rates of change of individual batteries in real operating conditions can be used to diagnose and foresee imminent failure, and in the event of a failure occurring the root cause of the problem can be found by using the historical data based BMS. To ensure further safety and reliability of acceptable practical operating conditions, rate of change limits are proposed based on battery characteristics for temperatures below 0.5 °C/min and voltages below 3.0 V/min.