Distributed generators (DGs) play an important role to reduce the real power loss and to improve the voltage stability of the power system. However, proper placement and sizing of DGs in the distribution network is a vital issue, as any improper location and size of DGs may increase the overall system loss. In this study, a novel chaotic symbiotic organisms search (CSOS) algorithm is proposed to find out the optimal location and sizes of real power DGs in a radial distribution system (RDS) considering constant load models. This DG siting and sizing problem is associated with real power loss minimisation and voltage stability improvement objectives. The effectiveness of the proposed algorithm is tested on benchmark test functions as well as on 33‐, 69‐ and 118‐bus RDS. The simulation results obtained by the proposed CSOS algorithm are compared with the results offered by the basic SOS and other nature inspired algorithms to establish the superiority of the proposed CSOS algorithm over the others in terms of quality of solution and convergence mobility.
1 July 2016 in IET Generation, Transmission & Distribution
Considering system uncertainties prevailing in the restructured power system, congestion management (CM) is a vital issue in power system operation and control. The objective of CM is to remove congestion in the lines while satisfying all the constraints with minimum congestion cost. This study proposes a generation rescheduling‐based approach for CM in electricity market using a novel ant lion optimiser (ALO) algorithm. ALO is a recently developed the nature‐inspired algorithm based on the hunting mechanism of antlions. The effectiveness of the proposed approach is tested on modified IEEE 30‐bus, modified IEEE 57‐bus and IEEE 118‐bus test systems. The security constraints like load bus voltage and line loading impact are incorporated in this study. To prove the validity of the proposed technique, the obtained results are compared to the results offered by various recent optimisation algorithms. The results show that the proposed ALO algorithm outperforms the other comparative algorithms. The proposed approach uses less number of fitness function evaluations, not traps into local minima and offers promising convergence characteristic. The proposed approach will ease the system operator to remove the contingency rapidly for secured and reliable operation of the power system under deregulated environment.
6 September 2017 in IET Generation, Transmission & Distribution
In this study, a novel fuzzy logic control scheme is investigated for the frequency and power control of an isolated hybrid power system (HPS) (IHPS) and HPS‐based two‐area power system. The studied IHPS comprises of various autonomous generation systems such as wind energy, diesel engine generator and an energy storage device (i.e. capacitor energy storage device). A novel fractional order (FO) fuzzy proportional‐integral‐derivative (PID) (FO‐F‐PID) controller scheme is deployed and the various tunable parameters of the studied model are tuned by quasi‐oppositional harmony search (HS) (QOHS) algorithm for improved performance. The QOHS algorithm (based on standard HS algorithm) accelerates the convergence speed by combining the concept of quasi‐opposition in the basic HS framework. This FO‐F‐PID controller shows better performance over the integer order‐PID and F‐PID controller in both linear and non‐linear operating regimes. The proposed FO‐F‐PID controller also shows stronger robustness properties against loading mismatch and different rate constraint non‐linarites than other controller structures.
This study presents an efficient and reliable evolutionary‐based approach, termed as chaotic krill herd algorithm (CKHA), to solve the optimal reactive power dispatch (ORPD) problem of power system. In the proposed CKHA, various chaotic maps are considered to improve the performance of the basic KHA. The performance of the proposed CKHA is examined and tested, successfully, on standard IEEE‐30 and IEEE‐57 bus test power systems for the solution of ORPD problem in which control of bus voltages, tap position of transformers and reactive power sources are involved. The objective function considered is either minimisation of active power transmission loss or that of total voltage deviation or enhancement of voltage stability index. The results offered by the proposed CKHA are compared with those offered by other evolutionary optimisation techniques surfaced in the recent state‐of‐the‐art literature. Simulation results indicate that the proposed CKHA yields superior solution over the other recently surfaced popular techniques in terms of effectiveness and convergence speed.