There is an unmet need for new techniques and methods of healing critical size tissue defects, by further reduction of invasiveness in implant, cell and tissue-based surgery. This paper presents the development of a new regenerative medicine that combines 3D bio-printing and robotic-assisted minimally invasive surgery techniques to meet this need. We investigated the feasibility of Remote Centre of Motion (RCM) and viscous material extrusion 3D printing. A hypothetical, intra-articular, regenerative medicine-based treatment technique for focal cartilage defects of the knee was used as a potential example of the application of 3D printing in vivo. The results of this study suggest, that RCM mechanism is feasible with viscous material extrusion 3D printing processes, without a major trade-off in imprint quality. The achieved printing accuracy at an average dimensional error of 0.06 ± 0.14 mm in this new modality of 3D printing is comparable to those described in literature for other types of bio-printing. Robotic assisted 3D bio-printing demonstrated here is a viable option for focal cartilage defect restoration.
27 January 2016 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
In the modern world, due to an increased aging population, hand disability is becoming increasingly common. The prevalence of conditions such as stroke is placing an ever-growing burden on the limited fiscal resources of health care providers and the capacity of their physical therapy staff. As a solution, this paper presents a novel design for a wearable and adaptive glove for patients so that they can practice rehabilitative activities at home, reducing the workload for therapists and increasing the patient's independence. As an initial evaluation of the design's feasibility the prototype was subjected to motion analysis to compare its performance with the hand in an assessment of grasping patterns of a selection of blocks and spheres. The outcomes of this paper suggest that the theory of design has validity and may lead to a system that could be successful in the treatment of stroke patients to guide them through finger flexion and extension, which could enable them to gain more control and confidence in interacting with the world around them.
It is essential to make sure patients be actively involved in motor training using robot-assisted rehabilitation to achieve better rehabilitation outcomes. This paper introduces an attention-controlled wrist rehabilitation method using a low-cost EEG sensor. Active rehabilitation training is realized using a threshold of the attention level measured by the low-cost EEG sensor as a switch for a flexible wrist exoskeleton assisting wrist flexion/extension and radial/ulnar deviation. We present a prototype implementation of this active training method and provide a preliminary evaluation. The feasibility of the attention-based control was proven with the overall actuation success rate of 95%. The experimental results also proved that the visual guidance was helpful for the users to concentrate on the wrist rehabilitation training: two types of visual guidance, namely, looking at the hand motion shown on a video and looking at the user’s own hand had no significant performance difference. A general threshold of a certain group of users can be utilized in the wrist robot control rather than a customized threshold to simplify the procedure.
This article describes a wearable sensor for monitoring the motion of human elbow and wrist joints. The sensor converts the joint motion angle into a displacement, which is monitored using a fiber-optic sensor based on reflective light intensity modulation. A mathematical model is established, and the potential influencing factors of the sensor are investigated. Two prototypes for elbow and wrist joint angle monitoring are fabricated and validated. The experimental results indicate that the proposed sensor has a measurement range of 0–60° (0–120°), with a resolution of 0.338° (3.6°) for monitoring the wrist joint palm flexion (elbow joint flexion). The proposed sensor has the potential to be used for rehabilitation purposes and monitoring of joint angles while performing reaching tasks, which are the most common upper-limb gestures. GRAPHICAL ABSTRACT
22 November 2017 in Annals of Biomedical Engineering
This paper presents a robotic flexible drill and its navigation system for total hip arthroplasty (THA). The new robotic system provides an unprecedented and unique capability to perform curved femoral milling under the guidance of a multimodality navigation system. The robotic system consists of three components. Firstly, a flexible drill manipulator comprises multiple rigid segments that act as a sheath to a flexible shaft with a drill/burr attached to the end. The second part of the robotic system is a hybrid tracking system that consists of an optical tracking system and a position tracking system. Optical tracking units are used to track the surgical objects and tools outside the drilling area, while a rotary encoder placed at each joint of the sheath is synchronized to provide the position information for the flexible manipulator with its virtual object. Finally, the flexible drill is integrated into a computer-aided navigation system. The navigation system provides real time guidance to a surgeon during the procedure. The flexible drill system is then able to implement THA by bone milling. The final section of this paper is an evaluation of the flexible and steerable drill and its navigation system for femoral bone milling in sawbones.
Hand exoskeleton pose monitoring is of great importance in the rehabilitation training of stroke patients to ensure precise robotic trajectory control and provide a patient recovery assessment mechanism. In this paper, a low-cost pose sensor unit based on the principle of photoelectric reflection is proposed to measure the pose of a multi-segment continuous structure in a hand rehabilitation exoskeleton. The sensor unit consists of five photosensitive elements that measure the rotation angle of an arrangement of adjacent segments, each integrated with a sensing element, to estimate the actuator’s motion. An accurate device with a user-friendly interface is then designed for calibration of the sensing elements. The experimental results indicate that the sensitivity exceeds 0.047 V/° for the sensing elements, and hysteresis and repeatability errors are less than 1.1% and 1.8%, respectively. A comparison between the proposed sensor output and the results benchmarked by a VICON motion capture system demonstrates that the sensor can measure the bending angle of the multi-segment structure with a mean error of 3.23 degrees.