Jie Qiu

Mr. Jie Qiu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2021 in Water
Verified
Journal Article
Open access
PDF file
Yongji ZhangYongji Zhang
Yongji Zhang
JQJie Qiu
Jie Qiu
XXXianfang Xu
Xianfang Xu
LZLingling Zhou
Lingling Zhou
With the widespread use of chloramines disinfection, nitrification has become a problem that cannot be ignored. In order to control nitrification in the drinking water distribution system (DWDS), the inactivation effect of free chlorine, monochloramine and chlorine dioxide on ammonia-oxidizing bacterium (AOB) was studied under different temperature (8 °C, 26 °C and 35 °C) and pH (6.0, 7.0 and 8.7) conditions. The inactivation effect of Nitrosomonas europaea (a kind of AOB) by the three disinfectants increases with increasing temperature. As for the raised pH, the inactivation effect of free chlorine and monochloramine on AOB decreased, while that of chlorine dioxide increased. Last, but certainly not least, the experimental data of the disinfection were calculated to develop the N. europaea inactivation kinetic model, which was based on the first order Chick–Watson equation. The proposed model in this study took the two variables, pH and temperature, into consideration simultaneously, which were used to evaluate the average Ct value (multiplying the concentration of the residual disinfectant by the time of contact with N. europaea) required for different disinfectants when they produced the ideal inactivation effect on N. europaea.

29 April 2024 in Water
Verified
Journal Article
Open access
PDF file
XZXiuneng Zhu
Xiuneng Zhu
JQJie Qiu
Jie Qiu
YWYexing Wang
Yexing Wang
Yulin TangYulin Tang
Yulin Tang
Yongji ZhangYongji Zhang
Yongji Zhang
There is more and more research focusing on the removal of dioxane by advanced oxidation technology at this stage, and this study investigated the efficacy of an advanced oxidation system with UV-activated persulfate (UV/PDS). This method had the advantages of fast reaction rate, simple equipment and convenient operation. Free radical quenching test and electron paramagnetic resonance (EPR) analysis showed that the main active radicals in the reaction system were SO4− and ·OH. This study also investigated that the optimal parameters were the initial PDS dosage of 3 mM, the UV intensity of 0.190 mM/cm2, the pH between 5 and 7 and the initial dioxane concentration of 50 mg/L. Additionally, after a reaction time of 150 min, the total organic carbon (TOC) content still remained at 83.53%, which revealed that the mineralization degree of organic matter was not fully achieved through UV/PDS treatment. The concentration of SO42− in the reaction system was 74.69 mg·L−1, which complied with the standard concentration specified. Furthermore, the cytotoxicity of the system exhibited an initial increase followed by a subsequent decrease, under the influence of the intermediates. It showed that the technology could efficiently degrade organic pollutants.